Cell Type CR-P2 Specifications W Nominal Capacity*1 Nominal Voltage Standard Discharge Current Continuous *2 Max. Discharge Current Pulse*3 Temperature Range Weight L L W H H Dimensions 1400mAh 6V 10mA 1500mA 3500mA -4060 37g 34.8mm 19.5mm 35.8mm *1 Nominal capacity is determined to an end voltage of 4.0V when the battery is allowed to discharge at a standard current level at 23oC. *2 Current value is determined to be the level at which 50% of the nominal capacity is obtained with an end voltage of 4.0V at 23 oC. *3 Current value for obtaining 2.0V cell voltage when pulse is applied for 15seconds at 50% discharge depth at 23 oC. Typical Characteristics Pulse Discharge Characteristics of CR-P2 Pulse Discharge Characteristics of CR-P2 7.0 7.0 Pulse: 1.2A*3s on/7s off Initial Pulse: 0.9A*3s on/27s off Initial 6.0 Cell Voltage(V) Cell Voltage(V) 6.0 5.0 23 o C 4.0 -20 o C 3.0 -20 o C 4.0 3.0 2.0 2.0 0 200 400 600 800 1000 1200 1400 1600 1800 Number of Cycles 7.0 Load: 400ohm Temp.: 23 o C Initial 6.0 5.0 4.0 3.0 2.0 0 10 20 30 40 50 60 70 80 Duration(hour) 90 0 200 400 600 800 1000 1200 Number of Cycles Discharge Characteristics of CR-P2 Cell Voltage(V) 23 o C 5.0 100 110 120 130 140 1400 1600 1800 2000