Description
• Axial Leaded
• Slow Blow, Wire-in-Air Design
• Tin-lead Plated Copper Lead Wires
• High Temperature Epoxy Plastic Body, UL 94 VO
• Interrupt 50 amperes at 125 VAC
Agency Information
•UL Recognition Guide & File numbers: JDYX2 &
E195337.
•CSA Certification Record No: LR 701159 & Class No:
1422 30 and 1422 01.
Environmental Data
•Shock Resistance:MIL-STD-202, Method 213, Test
Condition 1 (Sawtooth)
•Vibration Resistance: MIL-STD-202, Method 201
(10-55 Hz x 3 axis/ no load)
•Moisture Resistance: MIL-STD-202F, Method 106
•Soldering Heat Resistance: 260°C, 10 seconds per
IEC 68-2-20
•Salt Spray: MIL-STD-202, Method 101, Test
Condition B (48 Hours)
Ordering
• Specify product code and packaging code
Soldering Method
• Heat Resistance: 260°C, 10 sec per IEC 68-2-20
Construction
Dimensions mm⁄(inches)
End View
*AC Interrupting Rating (Measured at designated voltage, 100%) DC Interrupting Rating (Measured at
designated voltage, rise time of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
†Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, rise time of
calibrated circuit less than 50 microseconds)
‡Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Subminiature Through Hole
MCRS Series, Slow Blow,Wire-in-Air
ELECTRICAL CHARACTERISTICS
% of Amp Rating Opening Time
100% 4 hours minimum
200% 30 seconds maximum
SPECIFICATIONS
Voltage Interrupting Resistance Typical Typical
Product Code Rating Rating* (ohms)** Melt Voltage
AC/DC AC DC Typ. I2t† Drop (V)‡
MCRS250mA 125 V 50 A 300 A 3.20 0.042 2.20
MCRS300mA 125 V 50 A 300 A 2.57 0.056 2.02
MCRS375mA 125 V 50 A 300 A 1.66 0.101 1.69
MCRS500mA 125 V 50 A 300 A 1.07 0.18 1.42
MCRS750mA 125 V 50 A 300 A 0.55 0.44 1.09
MCRS1A 125 V 50 A 300 A 0.36 0.78 0.91
MCRS1.25A 125 V 50 A 300 A 0.23 1.41 0.77
MCRS1.5A 125 V 50 A 300 A 0.18 1.9 0.7
MCRS2A 125 V 50 A 300 A 0.12 3.4 0.59
MCRS2.5A 125 V 50 A 300 A 0.08 6.1 0.5
MCRS3A 125 V 50 A 300 A 0.06 8.1 0.45
MCRS4A 125 V 50 A 300 A 0.04 15 0.38
MCRS5A 125 V 50 A 300 A 0.02 35 0.29
MCRS7A 125 V 50 A 300 A 0.01 63 0.25