46
Convergent-reflective Models Indicates models that allow free cutting.
Heat-resistant Models
Chemical-resistant Models
Fiber Units with Reflective Sensors
A
Two, 4 dia.
Optical axis
Sensing head (stainless steel)
Two, 3.2-dia. holes with 6-dia. countersinks on one side
Flexible tube: 2.8 dia.*1
5.5
B
25
33.5
27
19
7
11
13 *25 (max.)
2,000
4 dia.
8.9 18
*1 Material: Stainless steel
E32-L86 Note: The maximum allowable temperatures
for sections A and B are 200C and
110C, respectively. The section insert-
ed into the Amplifier Unit (indicated by
*2), however, must stay within the Am-
plifier Unit's operating temperature
range.
Two, 1.5 dia.
3.1
4.9
Two hexagonal nuts
Two toothed washers
Sensing head: M6 × 0.75* Optical fiber: Two, 2.2 dia.
2.4
133
17 2,000
10
*Material: Brass/nickel platin
E32-D51
Note: The maximum allowable temperature is 150C. The maximum
allowable temperature for continuous operation is 130C.
B
5 dia. 2.2 dia. Sleeve
SUS flexible tube
15
11.5
510 *2
4.5
5
8.5
SUS303
Fiber: 1.2 dia. Sleeve
M4 × 0.7
2.2 dia.
Sensing head: M6 × 0.75 *1
6.4
3
2
5 dia.
8
15
13 *220 5
6.5
16.5
B
5
(70)
A
3
(4.2 dia.)
2,000
Two toothed washers (SUS)
Two hexagonal nuts (SUS)
*1. Material: Stainless steel (SUS303)
Protective tube (gray)
E32-D81R-S
E32-D81R Note 1. The maximum allowable tempera-
tures for sections A and B are 200C
and 110C, respectively. The section
inserted into the Amplifier Unit (indi-
cated by *2), however, must stay
within the Amplifier Unit's operating
temperature range.
Using the E32-D81R-S Using the E32-D81R
10
AB
20 5 *4
3
2,000
5 dia. 2.2 dia. Sleeve
5 dia. *3 3.5 dia.
SUS flexible tube
Two hexagonal nuts
Two toothed washers
Sensing head: M6 × 0.75 *1
1.4 dia. M4 × 0.7
15
11.5
510 *2
4.5
5
8.5
322.4
*1. Material: Stainless steel (SUS303)
*3. The diameter is 6 if the fiber length exceeds 10 m.
*4. The diameter is 10 if the fiber len
th exceeds 10 m.
B
Sleeve
5 dia.
Hexagonal
caulking
SUS316L
16.5 6.5
5 *2
13
8
6.4
15
E32-D61-S
E32-D61 Note 1. The maximum allowable tempera-
tures for sections A and B are 350C
and 110C, respectively. The section
inserted into the Amplifier Unit (indi-
cated by *2), however, must stay
within the Amplifier Unit's operating
temperature range.
Using the E32-D61-S Using the E32-D61
5
7
60 20 10 2,000 16.5 *2
13
5
AB C
2.4 56.5 6.4
1
8
Sleeve
5 dia.
4 dia. 2.8 dia.
Hexagonal caulking SUS316L
SUS flexible tube
Two toothed washers
Two hexagonal nuts
Sensing head: M4 × 0.7 *1
2.5 dia.
1.65 dia.
Stainless-steel tube:
1.25 dia.
1 dia.
*1. Material: Stainless steel (SUS303)
C
5 dia. 2.2 dia. Sleeve
15
11.5
510 *2
4.5
5
8.5
E32-D73-S
E32-D73 Note 1. The maximum allowable tempera-
tures for sections A, B, and C are
400C, 300C, and 110C, respec-
tively. The section inserted into the
Amplifier Unit (indicated by *2), how-
ever, must stay within the Amplifier
Unit's operating temperature range.
Using the E32-D73-S Using the E32-D73
2,000
16
100
Sensing head: 6 dia. Fluororesin 5 dia. Optical fiber: Two, 2.2 dia.
E32-D12F
100
2,000
4.5
(26) Fluororesin tube
(protective cover)
Optical-axis mark
Optical
axis
Sensing head: 7 dia. Optical fiber: 2.2 dia.
E32-D14F