125
For Most Recent Data, Consult the Coto Technology Website: www.cotorelay.com 6 E-mail: info@cotorelay.com
RI-08 Series Dry Reed Switch
nor a switch kept closed by an 80 AT coil to open.
Vibration
The switches are tested in accordance with “IEC
68-2-6”, test Fc (acceleration 10 G; below cross-over
frequency 57 to 62 Hz; amplitude 0.75 mm; frequency
range 10 to 2000 Hz, duration 90 minutes). Such a
vibration will not cause an open switch (no magnetic
field present) to close, nor a switch kept closed by an
80 AT coil to open.
Mechanical Strength
The robustness of the terminations is tested in accor-
dance with “IEC 68-2-21”, test Ua1 (load 40 N).
Operating and Storage Temperature
Operating ambient temperature; min: -55°C; max:
+125°C. Storage temperature; min: -55°C; max:
+125°C. Note: Temperature excursions up to 150°C
may be permissible. For more information contact your
nearest Coto Technology sales office.
Soldering
The switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ±10°C for 3.5 ±0.5 s. Solderability is tested in
accordance with “IEC 68-2-20”, test Ta, method 3:
solder globule temperature 235°C; ageing 1b: 4 hours
steam.
Welding
The leads can be welded.
Mounting
The leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be
avoided. Care must be taken to prevent stray magnetic
fields from influencing the operating and measuring
conditions.
Model Number
RI-08AA RI-08A RI-08B
Parameters Test Conditions Units
Operating Characteristics
Operate Range AT 10.5-19 15-28 24-51
Release Range AT 4-12 5-16 8-20.5
Operate Time - including bounce (typ.) (energization) ms 0.35 (24AT) 0.35 (35AT) 0.35 (64AT)
Bounce Time (typ.) (energization) ms 0.15 (24AT) 0.15 (35AT) 0.15 (64AT)
Release Time (max) (energization)
µ
s30 (24AT) 30 (35AT) 30 (64AT)
Resonant Frequency (typ.) Hz 3200 3200 3200
Electrical Characteristics
Switched Power (max) W 30 30 40
Switched Voltage DC (max) V 200 200 200
Switched Voltage AC, RMS value (max) V 200 200 250
Switched Current DC (max) mA 750 1000 1000
Switched Current AC, RMS value (max) mA 750 1000 1000
Carry Current DC (max) A 1.75 2.25 3.0
Breakdown Voltage (min) V 300 400 580
Contact Resistance (initial max) (energization) m
Ω
120 (27 AT) 120 (27AT) 120 (36 AT)
Contact Resistance (initial typ.) (energization) m
Ω
90 (27 AT) 90 (27 AT) 90 (36 AT)
Contact Capacitance (max) without test coil pF 0.20 0.20 0.20
Insulation Resistance (min) RH
≤
45% M
Ω
10
6
10
6
x10
6