SE-600 600W Single Output Power Supply series Features : AC input active surge current limiting AC input range selected by switch Protections:Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan High power density 4.9w/in Built-in remote sense function UL approved Low cost 2 years warranty 3 K60950-1 (for 12V,24V only) SPECIFICATION (Note.6) SE-600-5 SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-36 SE-600-48 5V 12V 15V 24V 27V 36V 48V RATED CURRENT 100A 50A 40A 25A 22.2A 16.6A 12.5A CURRENT RANGE 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 25A 0 ~ 22.2A 0 ~ 16.6A 0 ~ 12.5A RATED POWER 500W 600W 600W 600W 599.4W 597.6W 600W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 22 ~ 26.4V 24 ~ 30V 1.0% 1.0% 32 ~ 40V 1.0% 1.0% 43 ~ 56V 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 20ms/230VAC VOLTAGE RANGE FREQUENCY RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch 47 ~ 63Hz 84% 83% 78% 87% 87% 88% 31 ~ 36.5V 42 ~ 50V 57.6 ~ 67.2V 12A/115VAC 1000ms, 50ms/115VAC at full load 16ms/115VAC at full load 254 ~ 370VDC 87% 7.5A/230VAC LEAKAGE CURRENT 30A/115VAC 60A/230VAC <2.0mA / 240VAC OVERLOAD 105 ~ 125% rated output power Protection type : Shut down o/p voltage, re-power on to recover OVER VOLTAGE 13.8 ~ 16.2V 27.6 ~ 32.4V 5.75 ~ 6.3V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +60 (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE MTBF DIMENSION PACKING NOTE 13.5 ~ 16.5V 1.0% LOAD REGULATION INRUSH CURRENT (Typ.) OTHERS 10 ~ 13.5V 1.0% LINE REGULATION EFFICIENCY (Typ.) AC CURRENT (Typ.) PROTECTION (Note.5) DC VOLTAGE MODEL OUTPUT R33100 RoHS -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1,UL62368-1, EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only) approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 197K hrs min. MIL-HDBK-217F (25) 247*127*63.5mm (L*W*H) 2.1Kg; 6pcs/13.4Kg/1.03CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 5. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W 6. Products made in Taiwan do not have KC logo. Please contact MEAN WELL sales for more information. File Name:SE-600-SPEC 2019-07-19 SE-600 600W Single Output Power Supply Mechanical Specification Case No. 926A 14 max. 20 63.5 30 8.2 1 2 I/P 3 127 1 2 3 O/P 4 5 6 CN4 RS + Air flow direction 13 220 247 10 11 10 Unit:mm 17 max. 4-M3 L=4 230/115VAC series +Adj. RS +- 16 220 20 30 4-M3 L=4 AC input terminal : Pin No. 1 2 3 DC Output terminal : Assignment AC/L AC/N FG Pin No. 1~3 4~6 RS Connector (CN4) : JST B-XH or equivalent Assignment +V -V Pin No. 1 2 Assignment +S -S Mating Housing JST XHP or equivalent Terminal JST SXH-001T or equivalent Block Diagram fosc : 68KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT FG O.L.P. O.T.P. PWM CONTROL Derating Curve +V -V O.V.P. Static Characteristics 100 100 Other 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 5V 60 50 40 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 90 180 95 190 100 200 115 230 130 260 INPUT VOLTAGE (VAC) 60Hz File Name:SE-600-SPEC 2019-07-19