SPECIFICATION
SE-600-5
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
5V
100A
0 ~ 100A
500W
150mVp-p
4.75 ~ 5.5V
±2.0%
±0.5%
±2.0%
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load
20ms/230VAC 16ms/115VAC at full load
90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC
47 ~ 63Hz
78%
12A/115VAC 7.5A/230VAC
30A/115VAC 60A/230VAC
<2.0mA / 240VAC
105 ~ 125% rated output power
5.75 ~ 6.3V 13.8 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL60950-1,UL62368-1, , BSMI CNS14336-1, KC K60950-1(for 12V,24V only) approvedEAC TP TC 004
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
197K hrs min. MIL-HDBK-217F (25 )
247*127*63.5mm (L*W*H)
2.1Kg; 6pcs/13.4Kg/1.03CUFT
83% 84% 87% 87% 88%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mVp-p
10 ~ 13.5V
150mVp-p
13.5 ~ 16.5V
150mVp-p
22 ~ 26.4V
150mVp-p
24 ~ 30V
200mVp-p
43 ~ 56V
12V
50A
0 ~ 50A
600W
15V
40A
0 ~ 40A
600W
24V
25A
0 ~ 25A
600W
27V
22.2A
0 ~ 22.2A
599.4W
48V
12.5A
0 ~ 12.5A
600W
SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-48
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher ℃℃
than 2000m(6500ft).
5 This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply.
under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c) the power supply is:
- installed in end-devices with average or continuous input power greater than 75W, or
- belong to part of a lighting system
Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200W
6. Products made in Taiwan do not have KC logo. Please contact MEAN WELL sales for more information.
File Name:SE-600-SPEC 2019-07-19
AC input active surge current limiting
AC input range selected by switch
Protections:Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
High power density 4.9w/in3
Built-in remote sense function
UL approved
Low cost
2 years warranty
Features :
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
600W Single Output Power Supply SE-600 series
SE-600-36
36V
16.6A
0 ~ 16.6A
597.6W
200mVp-p
32 ~ 40V
±1.0%
±0.5%
±0.5%
42 ~ 50V
87%
R33100
RoHS (Note.5)
(Note.6)
K60950-1
(for 12V,24V only)
Mechanical Specification
Derating Curve Static Characteristics
Case No. 926A Unit:mm
AMBIENT TEMPERATURE ( )
LOAD (%)
LOAD (%)
20
40
60
80
100
INPUT VOLTAGE (VAC) 60Hz
90
180
95
190
100
200
115
230
130
260
90
100
80
70
60
50
40
-20010203040506070
(HORIZONTAL)
5V
Other
600W Single Output Power Supply SE-600 series
Block Diagram fosc : 68KHz
O.V.P.
CONTROL
FG
I/P -V
+V
RECTIFIERS
&
FILTER
SWITCHING
POWER
FILTER
&
RECTIFIERS
FILTER
EMI
O.L.P.
DETECTION
CIRCUIT
PWM
O.T.P.
1
3
2
AC/L
AC/N
1~3
4~6
+V
FG
-V
1
2
+S
-S
JST XHP
or equivalent
JST SXH-001T
or equivalent
AC input terminal :
Pin No. Assignment
DC Output terminal :
Pin No. Assignment
RS Connector (CN4) : JST B-XH or equivalent
Pin No. Assignment Mating Housing Terminal
230/115VAC
8.2
10
1
2
3
4-M3 L=4
11 220
220 16
247
20
30
30
20
63.5
1
2
3
4
5
6
13
10
127
I/P
O/P
+Adj.
RS
-
+
CN4
RS
-
+
4-M3 L=4
14 max. 17 max.
Air flow
direction
File Name:SE-600-SPEC 2019-07-19