660VDC FERRULE FUSES /SPECIAL PURPOSE 660V DC gRB FROM 0.8 TO 110A SIZE: 27X60 Dimensions 60,3 O 27 7 O5 Trip force: 4.5N at 0mm-2.5N at 7mm G APPLICATIONS DATA SIZE CURRENT RATING IN(A) 27 x 60 0.8 1 1.5 2 3.15 4 5 6.3 8 10 12 16 20 25 32 40 50 63 80 100 110 INTERRUPTING RATING @ 660V DC 50kA L/R = 15ms WATTS LOSS 0.8 IN IN 0.25 0.25 0.35 0.4 0.6 0.6 0.7 0.8 1.2 1.3 1.4 1.9 2.4 2.8 3.5 4.7 4.8 5.6 6.4 7.4 7.7 0.4 0.4 0.6 0.7 1 1 1.1 1.3 2 2.3 2.4 3.3 4.1 4.7 6 8 8.3 9.6 11.2 12.9 13.7 Minimum trip voltage: 20V See Fuse Blocks and Fuse Holders. G 33 CATALOG NUMBER CC 6,621 CPgRB 27x60/0.8 CC 6,621 CP gRB 27x60/1 CC 6,621 CP gRB 27x60/1.5 CC 6,621 CP gRB 27x60/2 CC 6,621 CP gRB 27x60/3.15 CC 6,621 CP gRB 27x60/4 CC 6,621 CP gRB 27x60/5 CC 6,621 CP gRB 27x60/6.3 CC 6,621 CP gRB 27x60/8 CC 6,621 CP gRB 27x60/10 CC 6,621 CP gRB 27x60/12 CC 6,621 CP gRB 27x60/16 CC 6,621 CP gRB 27x60/20 CC 6,621 CP gRB 27x60/25 CC 6,621 CP gRB 27x60/32 CC 6,621 CP gRB 27x60/40 CC 6,621 CP gRB 27x60/50 CC 6,621 CP gRB 27x60/63 CC 6,621 CP gRB 27x60/80 CC 6,621 CP gRB 27x60/100 CC 6,621 CP gRB 27x60/110 REF. NUMBER H098585 J098586 K098587 P098591 Q098592 R098593 T098595 Z098600 L076301 M076302 L075703 N076303 C077006 M075635 P076304 Q076305 R076306 P079961 S079964 T099400 S076307 1000V DC FERRULE FUSES /SPECIAL PURPOSE DC Application Data Peak Arc voltage vs. working voltage Um (V) L/R (ms) 2000 90 80 70 60 50 40 30 20 10 0 1800 1600 1400 1200 1000 600 1200 1100 1000 900 800 700 800 400 Above: Curve indicates the maximum permissible value of time constant L/R as a function of DC working voltage. 200 0 Max. AC voltage (50/60 Hz): 1500V with interrrupting rating of 100kA. 0 100 300 500 700 900 U(V) 1-L/R = 50ms 2-L/R = 25ms 3-L/R = 15ms Above: Curves indicate for various time constants L/R the peak arc voltage, which may appear across the fuse terminals, vs. DC working voltage. Time vs. current characteristics 10 4 8 10 12 16 20 25 32 40 50 63 6 t (s) a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 3 10 2 10 + 9% tolerance for mean - 1 pre-arcing current 10-1 10-2 10-3 10-4 1 10 10 2 10 3 I(A) Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. G 34 10 4 1500V DC FERRULE FUSES /SPECIAL PURPOSE 1500V DC gRB-gRD FROM 0.8 TO 25A SIZE: 20X127 Dimensions 7 mini 127 20.6 5 CC 1551...... Weight: 87g Trip force: 4.5N at 0mm-2.5N at 7mm 8 Weight: 87g G APPLICATIONS DATA SIZE 20 x 127 CURRENT RATING IN(A) 0.8 1 1.5 2 3.15 4 5 0.8 1 1.5 2 3.15 4 5 6 8 10 12 16 20 25 INTERRUPTING RATING @ 1000V DC 100kA L/R = 100ms @ 1000V DC 30kA L/R = 30ms @ 1500V DC 30kA L/R = 55ms WATTS LOSS 0.8 IN IN 0.5 0.5 0.8 0.9 1.2 1.3 1.4 0.5 0.5 0.8 0.9 1.2 1.3 1.4 3.4 3.3 3.5 3.9 5 5.3 6.6 0.9 0.9 1.4 1.6 2.1 2.1 2.3 0.9 0.9 1.4 1.6 2.1 2.1 2.3 6.3 6.0 6.1 6.8 8.9 9.6 12 CATALOG NUMBER CC 1551 CP gRB 20x127/0.8 CC 1551 CP gRB 20x127/1 CC 1551 CP gRB 20x127/1.5 CC 1551 CP gRB 20x127/2 CC 1551 CP gRB 20x127/3.15 CC 1551 CP gRB 20x127/4 CC 1551 CP gRB 20x127/5 CC 1500 CP gRB 20x127/0.8 CC 1500 CP gRB 20x127/1 CC 1500 CP gRB 20x127/1.5 CC 1500 CP gRB 20x127/2 CC 1500 CP gRB 20x127/3.15 CC 1500 CP gRB 20x127/4 CC 1500 CP gRB 20x127/5 CC 1500 CP gRD 20x127/6 CC 1500 CP gRD 20x127/8 CC 1500 CP gRD 20x127/10 CC 1500 CP gRD 20x12712 CC 1500 CP gRD 20x127/16 CC 1500 CP gRD 20x127/20 CC 1500 CP gRD 20x127/25 Minimum trip voltage: 50V (1) Fuses CC 1551 CP gRB 20x...D150 gRB...UL Recognized See Fuse Blocks and Fuse Holders, and Medium Voltage fuse clips G 35 D 150 gRB 0.8 VI(1) D 150 gRB 001 VI(1) D 150 gRB 01.5 VI(1) D 150 gRB 002 VI(1) D 150 gRB 3.15 VI(1) D 150 gRB 004 VI(1) D 150 gRB 005 VI(1) D 150 gRB 0.8 V D 150 gRB 001 V D 150 gRB 01.5 V D 150 gRB 002 V D 150 gRB 3.15 V D 150 gRB 004 V D 150 gRB 005 V D 150 gRB 006 V D 150 gRB 008 V D 150 gRB 010 V D 150 gRB 012 V D 150 gRB 016 V D 150 gRB 020 V D 150 gRB 025 V REF. NUMBER E075743 E075744 G075745 B088367 H075746 J075747 C088368 J081842 R079894 K081843 Y099243 L081844 Z099244 A099245 E082804 Z080867 F081655 B080593 Q081457 D082803 A080431 PACK 3 and 10 pieces 1500V DC FERRULE FUSES/SPECIAL PURPOSE DC Application Data Peak Arc voltage vs. working voltage L/R (ms) 90 80 70 60 50 40 30 20 10 0 4000 3000 2000 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage. 2000 1500 1000 500 0 2600 2200 1800 1400 1000 1000 U (V) Curve 1: gRD @ L/R = 30ms Curve 2: gRB @ L/R = 60ms Curve 3: gRD @ L/R = 15ms Curve 4: gRB @ L/R = 30ms Max. AC voltage (50/60 Hz): 2500V with interrrupting rating of 50kA. Above: Curves indicate for various time constants L/R peak arc voltage, which may appear across the fuse terminals, vs. DC working voltage. Time vs. current characteristics a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 3 10 2 8 10 12 16 20 25 gRB without trip indicator 6 3.15 4 5 0.8 1 1.5 2 10 4 gRB with indicator 0.8 1 1.5 2 3.15 4 5 gRB without trip indicator t (s) a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 1 10-1 10-2 10-3 10-4 1 10 10 2 10 3 1 10 10 2 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. 10 3 1 + 9% tolerance for mean - pre-arcing current G 36 10 10 2 10 3 I (A) 1500V DC FERRULE FUSES /SPECIAL PURPOSE 1500V DC gRC FROM 6 TO 32A SIZE: 20X190 Dimensions 7 mini 190 CC 1591 20.6 5 Weight: 176 g CC 1500 Weight: 176 g Trip force: 4.5N at 0mm - 2.5N at 7mm G APPLICATIONS DATA SIZE 20 x 190 CURRENT RATING IN(A) 6 8 10 12 16 20 25 32 6 8 10 12 16 20 25 32 INTERRUPTING RATING @ 1500V DC 60kA L/R = 40ms WATTS LOSS 0.8 IN IN 4.8 5.3 6.5 7.0 8.0 9.5 12 16 4.8 5.3 6.5 7.0 8.0 9.5 12 16 7.8 8.8 10.5 11.5 13 15 19.5 26 7.8 8.8 10.5 11.5 13 15 19.5 26 Minimum trip voltage: 90V See Fuse Blocks and Fuse Holders, and Medium Voltage fuse clips G 37 CATALOG NUMBER CC 1591 CP gRC 20x190/6 CC 1591 CP gRC 20x190/8 CC 1591 CP gRC 20x190/10 CC 1591 CP gRC 20x190/12 CC 1591 CP gRC 20x190/16 CC 1591 CP gRC 20x190/20 CC 1591 CP gRC 20x190/25 CC 1591 CP gRC 20x190/32 CC 1500 CP gRC 20x190/6 CC 1500 CP gRC 20x190/8 CC 1500 CP gRC 20x190/10 CC 1500 CP gRC 20x190/12 CC 1500 CP gRC 20x190/16 CC 1500 CP gRC 20x190/20 CC 1500 CP gRC 20x190/25 CC 1500 CP gRC 20x190/32 REF. NUMBER D083102 V083738 G087245 Y080429 N088378 Q087345 Z080430 G085911 Z089469 A089470 B089471 C089472 D089473 E089474 F089475 G089476 PACK 10 pieces AMP-TRAP(R) 1500V DC FERRULE FUSES /SPECIAL PURPOSE DC Application Data Peak Arc voltage vs. working voltage L/R (ms) Um (V) 90 80 70 60 50 40 30 20 10 0 4500 1 1500 2000 1500 Max. AC voltage (50/60 Hz): 2500V with interrrupting rating of 50kA. Above: Curves indicate for various time constants L/R peak arc voltage, which may appear across the fuse terminals, vs. DC working voltage. 10 12 16 20 25 32 8 6 1000 1-L/R = 45ms 2-L/R = 15ms a=130 A2=0.6 B1=1.25 B2=0.6 Cf3=0.8 10 3 10 2 10 + 7% tolerance for mean - pre-arcing current 1 10-1 10-2 10-3 10 U (V) Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage. t (s) 10-4 500 0 2000 1800 1600 1400 1200 1000 0 U (V) Time vs. current characteristics 10 4 2 3000 10 2 10 3 10 4 I (A) Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. G 38