Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1865A Coax - Sub-Miniature For more Information please call 1-800-Belden1 General Description: 25 AWG stranded (19x37) .021" bare copper conductor, gas-injected foam HDPE insulation, Duofoil(R) + tinned copper braid shield (95% coverage), PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (mm) 1 25 19x37 BC - Bare Copper 0.5334 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (mm) Gas-injected FHDPE - Foam High Density Polyethylene 2.3876 Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Duofoil(R) 2 Coverage (%) Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 Braid TC - Tinned Copper 95 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 3.810 mm Mechanical Characteristics (Overall) Operating Temperature Range: -30C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 20.835 Kg/Km Max. Recommended Pulling Tension: 120.101 N Min. Bend Radius/Minor Axis: 38.100 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1865A Coax - Sub-Miniature EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes RG Type: Sub-miniature 59/U Flame Test UL Flame Test: UL1666 Vertical Shaft Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/m) 0.305133 Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 54.1365 Nominal Velocity of Propagation: VP (%) 82 Nominal Delay: Delay (ns/m) 4.06844 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 89.8994 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 17.7174 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100m) 1 1.54207 3.58 3.281 5 3.6091 7 4.2653 10 5.2496 67.5 11.8116 71.5 12.1397 88.5 13.4521 100 14.4364 135 16.405 143 16.7331 180 19.0298 270 23.2951 360 26.9042 540 33.1381 720 38.7158 Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1865A Coax - Sub-Miniature 750 39.372 1000 45.6059 1500 55.777 2000 64.3076 2250 68.2448 3000 78.744 Max. Operating Voltage - UL: Voltage 300 V RMS Other Electrical Characteristic 1: Impedance tested in accordance with ASTM D-4566 paragraph 48.2, option 2 using a 75 Ohm fixed bridge and termination. 75 +/- 1.5 Ohms Other Electrical Characteristic 2: Return Loss tested in accordance with ASTM D-4566 paragraph 50.3, using a 75 Ohm fixed bridge and termination. Minimum Return Loss: Start Freq. (MHz) Stop Freq. (MHz) Min. RL (dB) 5.000 850.000 21.000 850.000 3000.000 18.000 Sweep Test Sweep Testing: 100% Sweep tested 5 MHz to 3 GHz. Put Ups and Colors: Item # Putup Ship Weight Color 1865A N3U1000 305 MT 7.258 KG GREEN, MIL Notes Item Desc 1865A 0011000 305 MT 7.258 KG BROWN C #25 GIFHDPE SH FR PVC 1865A 0021000 305 MT 7.258 KG RED C #25 GIFHDPE SH FR PVC 1865A 0031000 305 MT 7.258 KG ORANGE 1865A 0041000 305 MT 7.258 KG YELLOW 1865A 0061000 305 MT 7.258 KG BLUE, LIGHT C #25 GIFHDPE SH FR PVC 1865A 0071000 305 MT 7.258 KG VIOLET C #25 GIFHDPE SH FR PVC 1865A 0081000 305 MT 7.258 KG GRAY 1865A 0091000 305 MT 7.258 KG WHITE C #25 GIFHDPE SH FR PVC 1865A 0101000 305 MT 7.258 KG BLACK C #25 GIFHDPE SH FR PVC #25 GIFHDPE SH FR PVC #25 GIFHDPE SH FR PVC #25 GIFHDPE SH FR PVC #25 GIFHDPE SH FR PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 5 Revision Date: 04-30-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013