System
Automatic
Timer
Shut-Off
Chip
Erasing
Capacity*
Typical
Intensity
(µW/cm2)
PE-140 No 9 8,000
PE-140T Yes 9 8,000
PE-240T Yes 12 9,600
PL-265T Yes 30 9,600
PR-125T Yes 25 17,000
PR-320T Yes 42 17,000
PC-1100A Yes 84 18,500
PC-2200A Yes 168 18,500
PC-3300A Yes 252 18,500
PC-4400A Yes 336 18,500
PC-4420A Yes 336 50,000**
PC-8820A Yes 840 70,000**
PC-9920A Yes 940
6" wafers (24)
8" wafers (12)
12" wafers (6)
8" w/ metal rings (6)
12" w/ metal rings (2)
70,000**
* Based on 24-pen EPROMs.
** Measured with Spectroline™ AccuMAX XR-1000 readout unit and XS-254 UV sensor detector.
FASTEST EPROM ERASING with Reliable
Systems
Whether you’re erasing one EPROM chip or a thousand,
you’ll want the latest and most advanced UV erasing system
available. We have thirteen high-performance systems to match
your specific needs and your budget. They are specially
designed to provide complete erasure of chips in as little as 3
minutes or less!
All Spectroline erasers are handsomely styled of rugged, anodized
aluminum and stainless steel. They have a safety interlock to protect
the user against accidental exposure to hazardous short wave
(254nm) UV radiation. And each system is backed by Spectronics
Corporation...the world’s largest manufacturer of UV EPROM
erasing equipment.
The PE-140, PE-140T and PE-240T are
low-cost, desk-top lamps. They are the
fastest, most efficient units of their size and
are specially designed for personal
and small-systems users. The PE-140
and PE-140T each feature a 4-watt tube,
while the PE-240T has two 4-watt tubes.
The PL-265T, PR-125T and PR-320T are
ideal lamps for data processing centers
and other medium-volume EPROM users.
The PL-265T is equipped with two 6-watt
tubes, while the PR-125T and PR-320T fea-
ture high-intensity, ozone-free grid tubes for
faster, more efficient erasing. All three units
will accept PC boards and metric cards up
to 4 x 9" (10 x 23cm).
The PC-Series are large-capacity cabinets
designed for high-volume production
requirements. They use ultra-high intensity,
ozone-free grid tubes with up to four times
the throughput of competitive systems.
All six units will accommodate PC boards,
metric cards and 3" - 8" (75-200mm) wafers.
In addition, the PC-3300A, PC-4400A,
PC-4420A, PC-8820A and PC-9920A
will accept open-face stocking tubes for
mass chip erasing without unloading.
Both the PC-8820B and the PC-9920A can
also accomodate 12" (300nm) wafers.
The AccuMAX short wave UV radiometers
measure the UV intensity of EPROM
erasers.
√
√
®
®