CSM_E6C3-C_DS_E_3_1
1
Rugged Incremental 50-mm-dia. Rotary Encoder
E6C3-C
Durable and Easy to Use
Sealed bearings with IP65 oil resistance.
Superior shaft loading performance.
Radial: 80 N, Thrust: 50 N
Be sure to read Safety Precautions on
page 4.
Ordering Information
Encoders [Refer to Dimensions on page 4.]
Note: Models with 2-m cable are also available. When ordering, specify the cable length at the end of the model number (example: E6C3-CWZ5GH 300P/R 2M).
Accessories (Order Separately) [Refer to Dimensions on Rotary Encoder Accessories.]
Refer to Accessories for details.
Power supply voltage Output configuration Resolution
(pulses/rotation) Connection method Model
12 to 24 VDC Complementary output
100, 200,
Pre-wired (1 m)
(See note.)
E6C3-CWZ5GH (resolution) 1M
Example: E6C3-CWZ5GH 100P/R 1M
300, 360, 500
600, 720, 800
1,000, 1,024, 1,200
1,500, 1,800, 2,000
2,048, 2,500, 3,600
5 to 12 VDC Voltage output
100, 200
E6C3-CWZ3EH (resolution) 1M
Example: E6C3-CWZ3EH 100P/R 1M
300, 360, 500
600, 720, 800
1,000, 1,024, 1,200
1,500, 1,800, 2,000
2,048, 2,500, 3,600
5 to 12 VDC Line-driver output
100, 200,
E6C3-CWZ3XH (resolution) 1M
Example: E6C3-CWZ3XH 100P/R 1M
300, 360, 500
600, 720, 800
1,000, 1,024, 1,200
1,500, 1,800, 2,000
2,048, 2,500, 3,600
Name Model Remarks
Couplings E69-C08B ---
E69-C68B Different end diameter (6 to 8 mm)
Flanges E69-FCA03 ---
E69-FCA04 E69-2 Servo Mounting Bracket provided.
Servo Mounting Bracket E69-2 Provided with E69-FCA04 Flange.
E6C3-C
2
Ratings and Specifications
*1. An inrush current of approximately 9 A will flow for approximately 0.1 ms when the power is turned ON.
*2. Complementary Output
The complementary output has two output
transistors (NPN and PNP) as shown below. These
two output transistors alternately turn ON and OFF
depending on the high or low output signal. When
using them, pull up to the positive power supply
voltage level or pull down to 0 V. The
complementary output allows flow-in or flow-out of
the output current and thus the rising and falling
speeds of signals are fast. This allows a long cable
distance. They can be connected to open-collector
input devices (NPN, PNP).
*3. The line driver output is a data transmission circuit compatible with RS-422A and long-distance transmission is possible with a twisted-pair cable. (AM26LS31
equivalent)
*4. The maximum electrical response speed is determined by the resolution and maximum response frequency as follows:
Maximum electrical response speed (rpm) = × 60
This means that the Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical response speed.
*5. The phase Z signal is output when cut face D on the shaft and the cable connection direction are as shown in the following diagram (output position range: ±15°).
Item Model E6C3-CWZ5GH E6C3-CWZ3EH E6C3-CWZ3XH
Power supply voltage 12 VDC10% to 24 VDC +15%,
ripple (p-p): 5% max.
5 VDC 5% to 12 VDC +10%,
ripple (p-p): 5% max.
Current consumption*1100 mA max.
Resolution (pulses/rotation) 100, 200, 300, 360, 500, 600, 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000, 2,048, 2,500, 3,600
Output phases Phases A, B, and Z*5 Phases A, A, B, B, Z, and Z
Output configuration Complementary outputs*2 Voltage output (NPN output) Line driver output*3
Output capacity
Output voltage: VH = Vcc = 3 V min.
(IO = 30 mA)
VL = 2 V max.
(IO = 30 mA)
Output current: ±30 mA
Output resistance: 2 k
Output current: 35 mA max.
Residual voltage: 0.7 V max.
AM26LS31 equivalent
Output current: High level: IO = 10 mA
Low level: IS = 10 mA
Output voltage: VO = 2.5 V min.
VS = 0.5 V max.
Maximum response
frequency*4125 kHz (65 kHz when using phase Z reset)
Phase difference between
outputs 90°±45° between A and B (1/4 T ± 1/8 T)
Rise and fall times of output 1 µs max.
(Cable length: 2 m, Output current: 30 mA)
1 µs max.
(Cable length: 2 m, Output current: 35
mA)
1 µs max.
(Cable length: 2 m, IO: 10 mA,
IS: 10 mA)
Starting torque 10 mN·m max. at room temperature, 30 mN·m max. at low temperature
Moment of inertia 2.0 × 106 kg·m2 max.; 1.9 × 106 kg·m2 max. at 500 P/R max.
Shaft loading Radial 80 N
Thrust 50 N
Maximum permissible speed 5,000 r/min
Protection circuits Power supply reverse polarity protection, Output load short-circuit protection ---
Ambient temperature range Operating: 10 to 70°C (with no icing), Storage: 25 to 85°C (with no icing)
Ambient humidity range Operating/Storage: 35% to 85% (with no condensation)
Insulation resistance 20 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 500 Hz, 150 m/s2 or 2-mm double amplitude for 11 min 3 times each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP65, in-house standards: oilproof
Connection method Pre-wired Models (Standard cable length: 1 m)
Material Case: Aluminum, Main unit: Aluminum, Shaft: SUS303
Weight (packed state) Approx. 300 g
Accessories Instruction manual
0 V
OUT
PNP
transistor
NPN
transistor
Power
supply
E6C3-CWZ5GH
Signal
Maximum response frequency
Resolution
120˚
120˚ 40 dia.
Cut face D
E6C3-C
3
I/O Circuit Diagrams
Note: 1. The shielded cable outer core (shield) is not connected to the inner area or to the case.
2. The phase A, phase B, and phase Z circuits are all identical.
3. Normally, connect GND to 0 V or to an external ground.
Model/Output Circuits Output mode Connection
E6C3-CWZ5GH
E6C3-CWZ3EH Voltage Output Model
E6C3-CWZ5GH Complementary Output Model
Direction of rotation: CW Direction of rotation: CCW
(as viewed from end of shaft) (as viewed from end of shaft)
E6C3-CWZ3EH
E6C3-CWZ3XH E6C3-CWZ3XH Line Driver Output Model
Direction of rotation: CW Direction of rotation: CCW
(as viewed from end of shaft) (as viewed from end of shaft)
7.5
7.5
GND
0 V
12 VDC -10% to
24 VDC +15%
30mA
max.
30 mA
max.
24
E6C3-C
main
circuit Output signal
(Black: phase A, White:
phase B, Orange: phase Z)
Blue
Brown
Shield
Black, white, orange
Phase A
Phase B
Phase Z
Phase A
Phase B
Phase Z
T(360˚)
H
L
H
L
H
L
H
L
H
L
H
L
T(360˚) CW CCW
1/4±1/8T (90˚±45˚)
1/4±1/8T (90˚±45˚)
Note: Phase A is 1/4 T ± 1/8 T
faster than phase B.
Note: Phase A is 1/4 T ± 1/8 T
slower than phase B.
Color Terminal
Brown Power supply (+Vcc)
Black Output phase A
White Output phase B
Orange Output phase Z
Blue 0 V (common)
2k
7.5
0 V
GND
5 VDC -5% to
12 VDC +10%
35mA
max.
NPN
transistor
E6C3-C
main
circuit
Output signal
(Black: phase A,
White: phase B,
Orange: phase Z)
Blue
Brown
Shield
Black, white, orange
(Black/red: phase A,
White/red: phase B,
orange/red: phase Z)
GND
0 V
5 VDC -5% to
12 VDC+10%
E6C3-C
main
circuit
Reversed output
Blue
Brown
Shield
Black, white,
orange
Black, white, orange
(with red stripe)
Non-reversed output
(Black: phase A,
White: phase B,
Orange: phase Z)
AM26
LS31
equiv-
alent
Phase A
Phase B
Phase Z
Phase A
Phase B
Phase Z
Phase A
Phase B
Phase Z
Phase A
Phase B
Phase Z
T(360˚)
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
H
L
T(360˚)
CWCW CCW
1/4±1/8T (90˚±45˚)
1/4±1/8T (90˚±45˚)
Note: Receiver: AM26LS32 equivalent
Color Terminal
Brown Power supply (+Vcc)
Black Output phase A
White Output phase B
Orange Output phase Z
Black/red
stripes Output phase A
White/red
stripes Output phase B
Orange/
red
stripes
Output phase Z
Blue 0 V (common)
E6C3-C
4
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the Encoder under ambient conditions that exceed the
ratings.
Wiring
Connections
Cable Extension Characteristics
When the cable length is extended, the output waveform startup
time is lengthened and it affects the phase difference
characteristics of phases A and B. Conditions will change
according to frequency, noise, and other factors. As a guideline,
use a cable length of 10 m* or less. If the cable must be more than
10 m, use a Model with a Line-driver Output or Complementary
Output (max. length for line-driver output: 100 m).
* Recommended Cable
Conductor cross section: 0.2 mm2
Spiral shield
Conductor resistance: 92 /km max. (20°C)
Insulation resistance: 5 /km min. (20°C)
The output waveform startup time changes not only according to
the length of the cable, but also according to the load resistance
and the cable type.
Extending the cable length not only changes the startup time, but
also increases the output residual voltage.
Connection
Spurious pulses may be generated when power is turned ON and
OFF. Wait at least 0.1 s after turning ON the power to the Encoder
before using the connected device, and stop using the connected
device at least 0.1 s before turning OFF the power to the Encoder.
Also, turn ON the power to the load only after turning ON the power
to the Encoder.
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Encoder
Accessories (Order Separately)
Servo Mounting Bracket
E69-2
Refer to Accessories for details.
WARNING
Precautions for Correct Use
E6C3-CWZ@@H
6
8.8
6
12 dia.
50 dia.
1
1
5
10
10
(15)
38
20
(58)
120˚±0.1
120˚±0.1
40±0.1 dia.
30 +0
-0.021 dia.
8 +0
-0.018 dia.
5-dia. oil-resistant PVC-insulated shielded cable with 5
conductors (line driver: 8 conductors) (Conductor cross section:
0.2 mm2, Insulator diameter: 1.1 mm), Standard length: 1 m
Cut face D: Phase Z position (±15˚)
Three, M4
holes;
Depth: 5 mm
The E69-C08B Coupling is sold separately.
Couplings
E69-C08B
E69-C68B
Flanges
E69-FCA03
E69-FCA04
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.