RL201
THRU
RL207
2 Amp
Silicon Rectifier
50 to 1000 Volts
Features
Low Cost
Low Leakage
Low Forward Voltage Drop
High Current Capability
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
A.230 .300 5.80 7.60
B.104 .140 2.60 3.60
C.026 .034 .70 .90
D1.000 --- 25.40 ---
Maximum Ratings
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Typical Thermal Resistance (R
θJA
) 40°C/W
MCC
Catalog
Number
Device
Marking Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
RL201 --- 50V 35V 50V
RL202 --- 100V 70V 100V
RL203 --- 200V 140V 200V
RL204 --- 400V 280V 400V
RL205 --- 600V 420V 600V
RL206 --- 800V 560V 800V
RL207 --- 1000V 700V 1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 2 A TA = 75°C
Peak Forward Surge
Current IFSM
60A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage VF1.0V IFM = 2.0A;
TA = 25°C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR5.0µA
50µATA = 25°C
TA = 100°C
Typical Junction
Capacitance CJ20pF Measured at
1.0MHz, VR=4.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
DO-15
A
B
C
D
D
Cathode
Mark
www.mccsemi.com
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
MCC
RL201 thru RL207
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 2
Forward Derating Curve
017550 75 100 125
0
.5
1.0
1.5
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
150
2.0
2.5
3.0
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - MicroAmperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
µAmps
.2 .4 .6 .8 1.0 1.2
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
Volts
Figure 3
Junction Capacitance
.1 .2 1.4 2 10 20 404 100 200
1
2
6
10
20
100
pF
Volts
60
40
4
400 1000
TJ=25°C
www.mccsemi.com
MCC
RL201 thru RL207
1 100
4
0
20
40
60
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
80
100
120
Figure 4
Typical Reverse Characteristics
Volts
.4
.6
2
1
Amps
20 120
40 60 80 100
.001
.002
.00
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
TJ=25°C
TJ=100°C
Instantaneous Reverse Current - Amps versus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com