Page 1 of 2 TPH Zero Halogen Cables TPH Zero Halogen Cables are designed for critical areas that are sensitive to corrosive and toxic effects from a fire. These cables generate little smoke and contain no halogens, which greatly improves the chances of survival in a fire. The tight buffered, premise style design provides a small and flexible cable that is easy to install and terminate. Cables are OFNR rated for use in most parts of a building. Features and Benefits The cable design is ideal for installation in any enclosed areas, such as tunnels and subways. Its low corrosive properties also make it ideal for computer rooms, central office switch locations and anywhere electronic equipment needs to be protected. Reduced corrosive and toxic effects when burned OFNR riser rated, UL listed Small, flexible construction Available with up to 48 fibers Applications TransitTunnel and subway installations Large computer facilities Central office switch locations Any heavily populated building ORDERING INFORMATION Fiber Optic Center, Inc., 23 Centre Street, New Bedford, MA, 02740-6322, USA Website: www.focenter.com e-mail: sales@focenter.com, Toll Free: (800) IS-FIBER, (800) 473-4237, Tel: (508) 992-6464, Fax: (508) 991-8876 Page 2 of 2 GENERAL SPECIFICATIONS Temperature: -40C (-40F) to 80C (176F) Storage, -20C (-4F) to 80C (176F) In-Servi ce Rati ngs: UL-1666 OFNR per NEC 770-51(b) and 770-53(b) C entral Strength Member: (above 12 fi bers) Epoxy/glass rod Outer Strength Member: Arami d fi ber yarn Jacket: Flame retardant low smoke zero halogen compound Maxi mum C rush Resi stance: 850 Lbsf/i nch (1485 N/cm) Maxi mum Verti cal Ri se: 1640 feet (500 meters) ORDERING INFORMATION Cable Part Numbering System 1 2 3 4 5 6 7 8 9 Jacket Type: A) Polyethlene B) PVC (General Purpose) C) Polyurethane D) Plenum E) CPE F) Single Armor/PE G) Single Armor/PVC K) Jet Fuel Resistant L) Single Armor (Zero Hal.) M) MTR N) Fig.-8 P) PVDf/Armor Q) Alum. Armor R) Riser Grade PVC S) Double Armor (Steel) U) Soft Plenum V) LTR Armor W) Water Blocked X) Special-Specify Y) Dielectric Fig.-8 Z) Zero-Hal. Central Strength Member: 1) Dielectric 2) Steel 3) Aramid Yarn (coated) N) None X) Special-Specify Cable Construction: B) Breakout C) Component D) Deploying G) Tight Buffer Heavy-Duty (Indoor/Outdoor) H) Heavy-Duty (Outdoor) K) Buffered Fiber M) Medium Service (Duct) P) Premise S) Simplex T) UNI-Pak U) Single Tube Outdoor (Arial/Burial) W) Ready Access Z) Zipcord X) Special-Specify Buffer Construction: 1) Tight Buffer 3) Single Fiber Loose Tube (gel filled) 4) Multi-fiber Loose Tube (gel filled) Number of Fibers: 001=1; 002=2; 012=12; (up to 216 fibers in some cable constructions) Fiber Grade: see fiber specifications at front of this section S) Standard P) Premium Q) High Performance T) Super Fiber Size: A) SM B) 50m C) 62.5m E) 100m F) 200m G) 200/230m PCS J) 200/230m HCS XX) Special-Specify Color Coding All BICC General cables, unless customized, follow the industry standard color code system for easy identification. Cables with 12 or fewer individual components will follow the color sequence: Blue, Orange, Green, Brown, Slate White, Red, Black, Yellow, Violet, Pink, Aqua. For cables having more than 12 fibers, grouping is done following the same sequence for the subgroup and for the fibers within it. Example: 24 fiber loose tube cable with six fibers in each of four tubesTube colors will be blue, orange, green and brown. Each tube will have one each of fibers in the first six colors (blue, orange, green, brown, slate, white). Fibers are then identified by tube color/fiber colorblue/white being the white fiber in the blue tube. When cables have more than 144 fibers, a black stripe is added to each of the first six colors in order to make 18 recognizable subgroups. In some cable designs, jacketed subgroups may be numbered for identification in lieu of color coding. FOR ADDITIONAL INFORMATION ON THIS OR OTHER PRODUCTS AND THEIR AVAILABILITY, PLEASE CONTACT FIBER OPTIC CENTER, INC. Fiber Optic Center, Inc., 23 Centre Street, New Bedford, MA, 02740-6322, USA Website: www.focenter.com e-mail: sales@focenter.com, Toll Free: (800) IS-FIBER, (800) 473-4237, Tel: (508) 992-6464, Fax: (508) 991-8876