Embedded Power for
Business-Critical Continuity
LPS250 Series
250 Watts
Special Features
• Activepowerfactorcorrection
• IECEN6100-3-2compliance
• Remotesense&remoteinhibit
• Powerfail
• Singlewirecurrentsharing
• Built-inEMIfilter
• 2:1Widerangeoutputvoltage
adjust
• 2Supervisoryoutputs5Vand12V
• Overvoltageprotection
• Overloadprotection
• Thermaloverloadprotection
• DCpowergood
• 120kHzswitchingfrequency
• Cover-C
• Optionaltopwithfancover-CF
• Optionalendfancover-CEF
Total Power: 250 Watts
Input Voltage: 85-264Vac
120-300Vdc
# of Outputs: Single
Electrical Specifications
Safety
Input
Inputrange: 85-264Vac;120-300Vdc
Frequency: 47-440Hz
Inrushcurrent: 20Amax,coldstart@25°C
Efficiency: 75% typical at full load
EMIfilter: FCC Class B conducted and radiated
CISPR22ClassBconductedandradiated
EN55022ClassBconductedandradiated
VDE0878PT3ClassBconductedandradiated
Safetyground
leakagecurrent:
<0.5mA@50/60Hz,264VACinput
Output
Maximumpower: Withcover:250Wwith30CFMforcedair.
(-C) (-CF) (CEF)
Supervisoryoutput: 5V@100mAregulated;12V@500mA
Adjustmentrange: 2:1wideratio
Hold-uptime: 20ms@250Wload,115VACnominalline
Overloadprotection: Shortcircuitprotectiononalloutputs.Caseoverloadprotected@
10-145%abovepeakrating
Overvoltageprotec-
tion:
5Voutput:5.7to6.7VDC.
Othermodels10%to25%abovenominaloutput
• VDE 0805/EN60950(IEC950)
11774-3336-1262
• UL UL1950 EI32002
• CSA CSA22.2-234Level5
LR53982C
• NEMKOEN60950/EMKO-TUE
P95102999(74-sec)203
• CB Certificate and report
2186
• CE Mark(LVD)
Rev. 07.05.12_158
LPS250 Series
1 of 3
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model Number Output Voltage Minimum Load Maximum Load with
30CFM Forced Air Peak Load 1Regulation 2Ripple P/P (PARD)3
LPS252-C 5V(3-6V) 1.50A 50A 60A ±2% 50mV
LPS253-C 12V(6-12)V 0.63A 21A 25A ±2% 120mV
LPS254-C 15(12-24V) 0.50A 16.7A 20A ±2% 150mV
LPS255-C 24V(24-48V) 0.32A 10.4A 12.5A ±2% 240mV
1.Peakcurrentlasting<30secondswithamaximum10%dutycycle.
2.At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings.
3.Peak-to-peakwith20MHzbandwidthand10µFinparallelwitha0.1µFcapacitoratratedlinevoltageandloadranges.
4.IfoptionalCForCEFfansarenotused,30CFMforcedaircoolingneedstobeprovidedandisrequiredthroughthelengthofthepowersupply.
Notconvectionrated.
5.Outputvoltageadjustmentrequiresaminimumload.
6.RemoteinhibitresetsOVPlatch
Note:-CFsuffixaddedtothemodelnumberindicatescoverwithtopfan.-CEFsuffixaddedtothemodelnumberindicatescoverwithdualend
mountedfancoverandACinlet.
Rev. 07.05.12_158
LPS250 Series
2 of 3
Operatingtemperature: 0°to50°Cambient;
derateeachoutputat2.5%perdegreefrom50°to70°C
Storagetemperature: -40°Cto+85°C
Temperaturecoefficient: ±0.4%per°C
Electromagnetic
susceptibility:
DesignedtomeetIEC801,-2,-3,-4,-5,-6,Level3
Humidity: Operating;non-condensing5%to95%
Vibration: Threeorthogonalaxes,sweepat1oct/min,5min.dwellatfourmajorresonances0.7G
peak5Hzto500Hz,operational
MTBFdemonstrated: >550,000hoursatfullloadand25°Cambientconditions
EnvironmentalSpecifications
LogicControl
Powerfailure: TTLLogicsignalgoeshigh50-150msecafter5Voutput.Itgoeslowatleast4msbeforelossof
regulation
Remoteon/off: Requiresanexternalcontact(N.OorN.C)toinhibitoutputs
DC-OK: TTLlogicgoeshigh50-150msecaftertheoutput.Itgoeslowwhenthereislossof
regulation.
Remotesense: Compensatesfor0.5Vleaddropminimum,willoperatewithoutremotesenseconnected.Reverse
connection protected
Embedded Power for
Business-Critical Continuity
Rev. 07.05.12_158
LPS250 Series
3 of 3
MechanicalDrawing
5.0 (127.0)
2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK3
SK1
12345678
3 2 1
SK5
+ve -ve
Terminal
Block TB1
O/P ADJ.
SK4
FAN
#6-32 (4 places)
5.46
(138.6)
8.52
(216.4)
M3 (4 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14) 1.30
(33.0)
Optional
(-CF)
Cover
with Fan
Optional
(-CEF)
Cover
with fans
10.32
(262.0)
SK7
FAN
AC Inlet
10.0
10.0
10.0
#6-32
M3
M3
#6-32
#6-32
Optional
(-CEF)
Cover
with fans
Optional
(-CF)
Cover
with Fan
.24 (6.1)
6-32 (2 places)
Main Output
6-32 (3 places)
PinAssignments
Connector
SK1 PIN1 Neutral
PIN2 Line
PIN3 Ground
SK3 PIN1 +Remotesense
PIN2 -Remotesense
PIN3 Remoteinhibit(N.O.)
PIN4 Remoteinhibit(N.C.)
PIN5 Common
PIN6 Currentsharing
PIN7 Power fail
PIN8 DCPowerGood
SK4 PIN1 +Fan’spowersource(12V@500mA)
Pin 2 -Fan’spowersource(12V@500mA)
SK5 PIN1
+Supervisoryoutputsupply(5V@100mA)
PIN2
-Supervisoryoutputsupply(5V@100mA)
SK7 PIN1 +Fan’spowersource(12V@500mA)
PIN2 -Fan’spowersource(12V@500mA)
MatingConnectors
SK3 Molex22-01-1084
PINS:08-70-0057
SK4 Molex22-01-3027
PINS:08-50-0114
SK5 Molex22-01-3027
PINS:08-50-0114
SK7 Molex22-01-3027
PINS:08-50-0114
EmersonNetworkPowerConnectorKit#70-841-005,includesallofthe
above
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±0.02”(±0.5mm)
3. Specificationsareatfactorysettings.
4. Toenablenormallyclosedremoteinhibit,cutjumperJ1.
5. Mountingmaximuminsertiondepthis0.12”.
6. Warranty:2year
7. Weight:2.6lb/1.19kg
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
information or for any errors or omissions.
EmersonandtheEmersonNetworkPower
logoaretrademarksofEmersonElectricCo.
©2012EmersonElectricCo.
Allrightsreserved.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-critical continuity.
ACPower
Connectivity
DCPower