For more Information
please call
1-800-Belden1
General Description:
Security, Pro Audio & Intercom Cable, Plenum-CMP, 2-18 AWG stranded bare copper pairs with FEP
insulation, Individually Beldfoil® shielded and Flamarrest® jacket
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
218 7BC - Bare Copper
Total Number of Conductors: 4
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
FEP - Fluorinated Ethylene Propylene 0.254
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding: 7
Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (mm)
Flamarrest® LS PVC - Low Smoke Polyvinyl Chloride 0.4191
Outer Jacket Ripcord: Yes
Overall Cable
Overall Nominal Diameter: 7.137 mm
Pair
Pair Color Code Chart:
Number Color
1Black and Red
2Black and White
Pair Lay Length & Direction:
Lay Length (mm)
47.625
Mechanical Characteristics (Overall)
UL Temperature Rating: 75°C
Bulk Cable Weight: 64.439 Kg/Km
Max. Recommended Pulling Tension: 523.108 N
Min. Bend Radius/Minor Axis: 69.850 mm
Page 1 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
6341PC Multi-Conductor - Pro Audio and Intercom Systems
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMP
CEC/C(UL) Specification: CMP
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: NFPA 262
C(UL) Flame Test: FT6
Plenum/Non-Plenum
Plenum (Y/N): Yes
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.52496
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
144.364
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
259.855
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
21.327
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/km)
47.246
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 47.246 Ohm/km
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
4 Amps per conductor @ 25°C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
6341PC 877U1000 1,000 FT 43.000 LB NATURAL 2 #18 FS PR FEP FLRST
6341PC 8771000 1,000 FT 45.000 LB NATURAL C 2 #18 FS PR FEP FLRST
6341PC 877500 500 FT 24.500 LB NATURAL 2 #18 FS PR FEP FLRST
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 2 Revision Date: 03-13-2013
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
Page 2 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
6341PC Multi-Conductor - Pro Audio and Intercom Systems
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
6341PC Multi-Conductor - Pro Audio and Intercom Systems