Intelligent Flag I/II V600-HA Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems * Doesn't need a program and can be used like a sensor. * Advanced line construction at minimal cost. * Saves space. * Precise installation not required (Transmission distance: 100 mm max.). * A verification function provided on multi-functional type. * Addition of 16-bit models to the series responds to applications from Kanban to quality control. * Equipped with a wiring reduction mode and communications parity check function (16-bit models). * Both NPN and PNP output available. * FCC certified. Ordering Information/Specifications Amplifier Type Item Model Power supply Read-only (8-bit) V600-HAR91 V600-HAR81 Multi-functional (8-bit) V600-HAM91 Read-only (16-bit) V600-HAM81 V600-HAR92 24 VDC 10%, ripple (p-p): 10% Current consumption 130 mA max. Input Transistor output or contact output Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit) OFF voltage: 15 to 30 VDC ON voltage: 0 to 5 VDC Input impedance: 8.2 k Applied voltage: 30 VDC max. Output NPN open collector output, 20 mA max. at 30 VDC, residual voltage: 2 V max. PNP open collector output, 20 mA max. at 30 VDC, residual voltage: 2 V max. NPN open collector output, 20 mA max. at 30 VDC, residual voltage: 2 V max. Transistor output OFF voltage: 15 to 30 VDC Input impedance: 8.2 k Short-circuit current: 3 mA (typical) (for 0-V short-circuit of INHIBIT/TRG) ON voltage: 0 to 5 VDC Applied voltage: 30 VDC max. PNP open collector out- NPN open collector output, 20 mA put, 20 mA max. at 30 max. at 30 VDC, residual voltage: 2 V VDC, residual voltage: 2 V max. max. Diagnostic functions Checks for CPU errors and transmission errors Insulation resistance 50 M max. (at 500 VDC) between cable terminals and case Dielectric strength 2 500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.) Intelligent Flag I/II V600-HA Type Item Model Read-only (8-bit) V600-HAR91 V600-HAR81 Multi-functional (8-bit) V600-HAM91 Read-only (16-bit) V600-HAM81 V600-HAR92 Vibration resistance Destruction: 10 to 150 Hz, 0.3-mm double amplitude, with 4 sweeps of 8 min each in Destruction: 10 to 150 Hz, 1.5-mm 3 directions double amplitude, with 4 sweeps of 8 min each in 3 directions Shock resistance Destruction: 294 m/s2, 3 times each in 6 directions Ambient temperature -10 to 55C (with no icing) Ambient humidity 35% to 85% (with no condensation) Storage temperature -25 to 65C Degree of protection IEC60529: IP40 Ground Ground to 100 or less. Material ABS resin (case) Cable length Standard, 0.5 m with a dedicated connector (See note.) Weight Approx. 170 g Approx. 180 g Note: The connector is not waterproof. If there is a possibility that the connector may be exposed to water, keep it inside the control box. Be sure to use the connector together with the separately sold interface cable. Functions V600-HAR91/-HAR81 (Read-only type) Write Reads the 8-bit data (1 byte) of the set address and outputs to the 8 data output lines. Writes on the set address the 8-bit (1 byte) data designated via the 8 data input lines. V600-HAM91/-HAM81 (Multi-functional type) Verify The amplifier has the following three basic functions. Read Reads the 8-bit (1 byte) data of the set address and outputs to the 8 data output lines. Reads the 8-bit data (1 byte) of the set address, compares with the 8bit (1 byte) data input via the 8 verification data input lines, and outputs the verification result. V600-HAR92 (Read-only type) Reads the 16-bit data (2 bytes) of the set address and outputs to the 16 data output lines. Interface Cable Amplifier V600-HAR91/81 (Connector: 20 pin) V600-HAM91/81 V600-HAR92 (Connector: 26 pin) Cable length Interface Cable 2m V600-A60R 5m V600-A61R 10 m V600-A62R 2m V600-A60M 5m V600-A61M 10 m V600-A62M Note: The interface cable connector is not waterproof. If there is a possibility that the connector may be exposed to water, keep it inside the control box. The maximum cable length is 10 m. Intelligent Flag I/II V600-HA 3 Sensor Model V600-HS51 V600-HS61 V600-HS63 V600-HS67 Shape Item Transmission frequency 530 kHz Ambient temperature -10 to 60C Storage temperature -25 to 75C Ambient humidity 35% to 95% Insulation resistance 50 M (at 500 VDC) between cable terminal and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between cable terminal and case (leakage current: 1 mA max.) Degree of protection IEC60529: IP67 Vibration resistance Destruction: 10 to 2,000 Hz, 3-mm double amplitude, with Destruction: 10 to 500 Hz, 2-mm double amplitude, with 3 2 sweeps of 15 min each in 3 directions sweeps of 11 min each in 3 directions Shock resistance Destruction: 981 m/s2, 3 times each in 3 directions (18 times total) Cable length 2 m (fixed) Wireless transmission error direction 16-bit CRC (Cyclic Redundancy Check) in both directions Indicator --- Power: green Weight Approx. 70 g Approx. 190 g -10 to 70C Destruction: 490 m/s2, 3 times each in 3 directions (18 times total) Approx. 540 g Transmission Distance Specifications Recommended Combinations Amplifier Data Carrier Memory EEPROM (Batteryless type) Memory SRAM (Built-inbattery type) V600-HAR91/-HAR81/-HAM91/-HAM81/-HAR92 Sensor V600-HS51 V600-HS61 V600-HS63 V600-HS67 V600-D23P53 0.5 to 3.0 mm 0.5 to 3.0 mm --- --- V600-D23P54 0.5 to 5.0 mm 0.5 to 5.5 mm --- --- V600-D23P55 0.5 to 7.0 mm 0.5 to 7.0 mm 0.5 to 9.5 mm --- V600-D23P61 0.5 to 8.0 mm 0.5 to 9.0 mm 2 to 16 mm --- V600-D23P66N --- --- 5 to 30 mm 5 to 35 mm V600-D23P66SP --- --- 5 to 25 mm 5 to 30 mm V600-D23P71 --- --- 5 to 35 mm 10 to 70 mm V600-D23P72 --- 0.5 to 18 mm 5 to 35 mm 10 to 50 mm V600-D8KR12 5 to 15 mm 5 to 18 mm 5 to 45 mm 10 to 60 mm V600-D8KR13 --- --- 10 to 30 mm 10 to 40 mm V600-D8KR04 --- --- 10 to 65 mm 10 to 100 mm V600-D2KR16 --- --- 2 to 15 mm --- Note: 1. The specifications take fluctuations in ambient temperature and slight differences between products into account. 2. The read distance and write distance are the same. 3. Sensor Installation Conditions * V600-HS51:When flush-mounted in iron Axial offset from the Data Carrier: 2.0 mm * V600-HS61: When surface-mounted on metal (ferrous) Axial offset from the Data Carrier: 2.0 mm * V600-HS63: When surface-mounted on metal (ferrous) Axial offset from the Data Carrier: 10.0 mm * V600-HS67: When surface-mounted on metal (ferrous) Axial offset from the Data Carrier: 10.0 mm 4. Data Carrier Installation Conditions * V600-D23P53/-P54: When flush-mounted in iron * V600-D23P55/-P66N/-P66SP/-P71/-P72: When surface-mounted on resin (no metal on the backside) * V600-D23P61: When surface-mounted on metal (ferrous) * V600-D8KR12/-13/-04: When surface-mounted on metal (ferrous) * V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface 5. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces. 6. The Data Carrier is stationary. 4 Intelligent Flag I/II V600-HA System Configuration Host Sensor (Cable length: fixed to 2 m) Programmable Controller, I/O terminal, B7A, CompoBus/S, etc. Sensor Controller Terminal block wiring Connector connection Interface cable V600-A6R V600-A6M Amplifier (Cable length: Connector pins: 20 fixed to 0.5 m, with connector) Cable lengths: 2 m, 5 m, interface 10 m Connector connection Amplifier Power supply 24 VDC V600 -HAR91/ HAR81 Connector connection Connector pins: 26 Cable lengths: 2 m, 5 m, 10 m Connector Connector connection connection Power supply 24 VDC V600 -HAM91/ HAM81 Connector connection Power supply 24 VDC V600 -HAR92 Connector connection Sensor V600-HS51 V600-HS61 V600-HS63 V600-HS67 Interface cable available in three lengths: 2 m, 5 m, and 10 m (10 m max.) Wireless transmission Wireless transmission Data Carrier V600 V600 V600 V600 V600 V600 V600 -D23P53 -D23P54 -D23P55 -D23P61 -D23P66N -D23P66SP -D23P71 V600 V600 V600 V600 -D23P72 -D8KR12 -D8KR04 -D2KR16 Intelligent Flag I/II V600-HA 5 Characteristic Data (Typical) Transmission Range Combinations with the V600-HS51 Sensor V600-HS51 & V600-D23P53 V600-HS51 & V600-D23P54 Y Y Y Y Y 12 X 8 V600-HS51 & V600-D23P55 Y 15 X X 8 10 4 5 4 -8 -4 0 4 8 X V600-HS51 & V600-D23P61 -4 0 8 4 12 -15 X -10 -5 0 X 5 10 10 10 15 X -30 -20 -10 0 20 10 X Y X 20 5 15 30 X 20 0 10 Y Y 30 10 -5 5 V600-HS51 & V600-D8KR12 Y Y 15 -10 -8 V600-HS51 & V600-D23P66N Y -15 -12 30 X -30 -20 -10 0 10 20 30 X Combinations with the V600-HS61 Sensor V600-HS61 & V600-D23P53 V600-HS61 & V600-D23P54 Y Y V600-HS61 & V600-D23P55 Y 15 12 8 Y Y Y X X X 8 10 4 5 4 -8 -4 0 4 8 X V600-HS61 & V600-D23P61 -12 -8 -4 0 4 8 12 X V600-HS61 & V600-D23P72 Y Y Y -15 -10 -5 5 10 Y X Y Y 30 X X 15 15 V600-HS61 & V600-D8KR12 30 20 0 X 20 20 10 10 10 5 -25 -20 -15 -10 6 -5 0 5 10 15 20 25 X -30 Intelligent Flag I/II V600-HA -20 -10 0 10 20 30 X -30 -20 -10 0 10 20 30 X Combinations with the V600-HS63 Sensor V600-HS63 & V600-D23P55 V600-HS63 & V600-D23P61 Y V600-HS63 & V600-D23P66N 30 Y Y Y Y 50 X Y 40 30 X 20 20 10 10 X 30 20 -30 -20 -10 0 20 10 30 X V600-HS63 & V600-D23P66SP Y -40 -30 -20 -10 0 10 20 30 40 X V600-HS63 & V600-D23P71 40 -50 -40 -30 -20 -10 10 20 30 40 Y Y 50 X Y 60 60 X X X 30 0 V600-HS63 & V600-D23P72 Y Y 50 10 40 40 20 20 20 10 -50 -40 -30 -20 -10 0 10 20 30 40 50 X V600-HS63 & V600-D8KR12 -60 -40 -20 0 20 40 -40 -20 Y 80 20 40 Y 60 X Y 60 X X X 60 40 0 V600-HS63 & V600-D2KR16 Y 60 -60 X V600-HS63 & V600-D8KR04 Y Y 60 40 40 20 -60 -40 -20 20 20 0 20 40 60 X -80 -60 -40 -20 0 20 40 60 80 X -80 -60 -40 Intelligent Flag I/II -20 0 20 V600-HA 40 60 80 X 7 Combinations with the V600-HS67 Sensor V600-HS67 & V600-D23P66N V600-HS67 & V600-D23P66SP Y Y Y 80 60 V600-HS67 & V600-D23P71 Y 100 Y 80 60 X Y 80 X X 60 40 40 20 20 40 -80 -60 -40 -20 0 20 40 60 80 X V600-HS67 & V600-D23P72 -80 -60 -40 -20 20 0 20 40 60 80 X -100 -80 -60 -40 -20 V600-HS67 & V600-D8KR12 Y Y Y 80 40 60 80 100 X Y Y Y 80 X 60 X 20 V600-HS67 & V600-D8KR13 80 100 0 X 60 60 40 40 20 20 40 20 -100 -80 -60 -40 -20 0 20 40 60 80 100 X -80 -60 -40 -20 0 20 40 60 -80 80 X -60 -40 -20 0 20 40 60 80 X V600-HS67 & V600-D8KR04 Y Y 120 X 80 40 -120 -80 -40 0 40 120 X 80 Transmission Time The transmission time refers to the time required for communications between the Sensor and the Data Carrier. It is used for calculating the travel speed of the auto command. DC speed Distance travelled in the transmission range (conveyor = Transmission time speed) Model V600-HAR91/-HAR81/-HAM91/-HAM81 Read Mode type Data Carrier type DATA READ mode, VERIFY READ mode V600-HAR92 Write BYTE mode Read BIT SET mode, BIT CLEAR mode DATA READ mode EEPROM 75 ms 138 ms 150 ms 77 ms SRAM 60 ms 95 ms 107 ms 62 ms Example: Combinations with the V600-HAR91, V600-HS63, and V600-D8KR04 Sensors. Y Note: 1. The DC speed varies depending on transmission distance Y and the axial offset. It is recommended that you refer to the transmission range graphs and use the product where the range is the largest. 2. This calculation is intended as a guideline only. Perform a test with the actual product prior to use. 3. This equation does not include transmission error processing. Y 80 X 60 40 20 -80 -60 -40 -20 0 20 40 60 80 X DC speed 75 x 10-3 (m) 75 (mm) = 75 (m/min) = (conveyor = 60 x 10-3 x 1/60 (min) 60 (ms) speed) 8 Intelligent Flag I/II V600-HA Circuit Configuration V600-HAR91 V600-HAM91 V600-HAR81 V600-HAM81 Input Circuit Input Circuit +DC 24 V Tr ON/ OFF IN 8.2 k IN Main circuit Main circuit 8.2 k Tr 0V 0V Output Circuit Output Circuit +DC OUT Main circuit Main circuit OUT 0V 0V V600-HAR92 Input Circuit 24 V 8.2 k ON/ OFF IN Main circuit Tr 0V Output Circuit OUT Main circuit 0V Precautions Cautions !Caution Be sure to house the V600-HA@91/-HA@81/-HA@92 together with their connectors and cable in control boxes when using them and do not expose them to water, oil, dust, metal powder, corrosive gas, or organic solvent, otherwise they may malfunction, suffer damage, or burn. !Caution The connectors of the V600-HA@91/-HA@81/-HA@92 can be mounted to metal plates, provided that there is an insulation plate with a thickness of 1.5 mm minimum between each of the connectors and metal plates. Input/Output The following OMRON products cannot be connected to this product. * CVM1-OD219, C20H, C28H, C40H, or C60H Programmable Controllers * Sensor Controllers other than from the S3D2 Series When using a contact output, pay careful attention to chattering and to the minimum switching current. Also note that the minimum switching current may be specified for some solid-state outputs. When connecting an inductive load or an electrical device that tends to generate noise to the output, connect a diode in parallel with the load. Connect the cathode side of the diode to the positive side of the power source. L Open collector output Diode DC power supply The Data Input and Data Output lines are set to "1" when the transistor turns ON and to "0" when it turns OFF. Do not use a solid-state output with the following ratings with the V600-HAM91/-HAM81, otherwise an external input error may result. 1. Maximum switching current: 1 A min. 2. Minimum switching current: 10 mA min. 3. Response time (ON to OFF): 3 ms min. Diode Peak inverse voltage Minimum of three times of the load voltage Average rectified current: 1 A Intelligent Flag I/II V600-HA 9 Power Supply Voltage I/O Interface Requirements Do not impose any voltage exceeding the rated voltage range. Doing so, or applying alternating current (100 VAC) may cause the product to explode or burn. 1. The TRG input must be 10 ms min. 2. The INHIBIT input must be 20 ms min. 3. Minimum of 5 ms is required as the transfer time of the Read/ Write Selection Input (W/R). 4. The read data output must be read after the Normal End Output is set to ON. Load Short-circuiting Do not short-circuit the load connected to the product or connect to the power supply. Doing so may cause the product to explode or burn. Connecting the Sensor Hold the black part of the connector, line up the notch and push it in until it clicks. Wiring Avoid wiring mistakes such as incorrect polarity in the power supply. Wiring mistakes may cause the product to explode or burn. Correct Use Grounding The FG line is provided for grounding to the earth. When using the Amplifier in an environment where it is exposed to large amounts of noise or if the V600-HA@91/-HA@81/-HA@92 Amplifier malfunctions, provide a Class-3 ground (ground resistance of 100 or less). Note that sharing the grounding wire with other equipment or grounding to the beam of a building will adversely affect the grounding effect. V600-HA91/81/92 FG Other equipment OK Less than 100 V600-HA91/81/92 FG Other equipment NG Compatibility with the SRAM Memory Type Data Carrier 1. If the Data Carrier is stationary in the transmission area for a long time when using the V600-HA@91/81 in the AUTO mode, or when using the V600-HAR92, it will drastically reduce the battery life. Therefore, stop the oscillation in the sensor either by turning off the power of the V600-HA@91/81/92 Amplifier or by setting the Inhibit input to ON. 2. Use a Data Carrier that has the oscillation frequency of 530 kHz. Note that the following models manufactured before February 1991 cannot be used. * V600-D2KR01 * V600-D2KR02 Less than 100 Mounting Precautions When Using the AUTO Mode Amplifier Spacing When installing V600-HA@91/V600-HA@81/V600-HA@92 Amplifiers in a row, provide a minimum space of 10 mm between Amplifiers in order to prevent them from being affected by the heat produced by each Amplifier. If transmitting to the Data Carrier while it is traveling under the AUTO mode, conduct tests to make sure that the travel speed and installation conditions are fully satisfied. 10 mm min. V600-HA91/81/92 When housing the Amplifiers in a box, provide a fan or ventilation opening for radiating the heat. When wiring power cables, which carry large current such as motor drive cables, near the V600-HA@91/81/92 Amplifiers, conduct necessary tests to make sure that the installation conditions are fully satisfied. 10 Intelligent Flag I/II V600-HA Dimensions Note: All units are in millimeters unless otherwise indicated. Amplifier V600-HAR91/-HAR81 25 * Enlarged Section of Mounting Hole 4.4 30 5.5 30 Two, mounting holes * Mounting Hole Dimensions 55 30u 21 6 2-M4 17.5 28.3 36.3 61.8 98 68.5 80 89 890.2 35.2 210.2 Vinyl-insulated round cord 5.8-mm dia., 13-conductor cable, standard length: 0.5 m 500 mm 28.1 XG4E-2031 8.2 44.7 25 Intelligent Flag I/II V600-HA 11 V600-HAM91/-HAM81 25 * Enlarged Section of Mounting Hole 4.4 30 5.5 30 Two mounting holes * Mounting Hole Dimensions 55 30 21 6 2-M4 17.5 28.3 36.3 44.3 52.3 61.8 98 89 68.5 75 80 890.2 35.2 210.2 Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m 500 mm 28.1 XG4E-2631 8.2 52.3 25 12 Intelligent Flag I/II V600-HA V600-HAR92 25 * Enlarged Section of Mounting Hole 4.4 30 5.5 30 Two, mounting holes * Mounting Hole Dimensions 55 30 21 6 2-M4 17.5 28.3 36.3 44.3 61.8 98 68.5 89 75 80 890.2 35.2 210.2 Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m 500 mm 28.1 XG4E-2631 52.3 8.2 25 Sensor V600-HS51 2 lock washers Vinyl-insulated round cord (4-mm dia.) Connector 2 lock nuts M12X1 13.7 dia. 9.6 dia. 7 Case: Brass Transmission window: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) 49.5 33 35 V600-HS61 30.5 18 4.5 8.5 120.2 49.5 18 Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) 13.7 dia. Connector Detection surface 10 2-3.5X5 (mounting holes) Vinyl-insulated round cord (4-mm dia.) 6.5 Intelligent Flag I/II V600-HA 13 V600-HS63 2-R5 4-R1 40 Two, 4.5-dia. mounting holes Vinyl-insulated round cord 6-mm dia (7/0.18-mm dia.), 8-conductor cable, Bushing 10 standard length: 2 m Connector 28 13.8 dia. 51.5 5 27 5 5 6 53 Power indicator (green) 20 13 18 23 11 Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) V600-HS67 Four, 4.5-dia. mounting holes 100 900.2 5 5 50 50 Connector Power indicator (green) 25 100 13.8 dia. 900.2 51.5 Bushing Vinyl-insulated round cord (6-mm dia.) 10 Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) 10 14 30 20 11 Interface Cable V600-A6@R (for V600-HAR91/-HAR81)) 10.6 +5 330 0 +100 L 0 205 205 7.6 30 205 305 37.6 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 13-conductor cable, standard length: 2 m 14 Intelligent Flag I/II V600-HA XG5M-2032-N Connector V600-A6@M (for V600-HAM91/-HAM81/-HAR92) 10.6 +5 330 0 +100 L 0 205 205 7.6 30 205 305 37.6 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length: 2 m Model L (m) V600-A60R/60M 2 V600-A61R/61M 5 V600-A62R/62M 10 Intelligent Flag I/II XG5M-2632-N Connector V600-HA 15 Terms and Conditions WARRANTY, LIMITATIONS OF LIABILITY of all possible uses of this product, nor is it intended to imply that the uses listed may be suitable for this product: WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. APPLICATION CONSIDERATIONS SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the product in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use which apply to the product. This information by itself is not sufficient for a complete determination of the suitability of the product in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. DISCLAIMERS PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. Complete terms and conditions for product purchase and use are on Omron's website at www.omron.com/oei - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 OMRON ELECTRONICS LLC OMRON CANADA, INC. OMRON ON-LINE One Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Toronto, Ontario M1B 5V8 847-843-7900 416-286-6465 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca For US technical support or other inquiries: 800-556-6766 Cat. No. GC RFID 4 16 Intelligent Flag I/II 5/03 V600-HA Specifications subject to change without notice Printed in USA