www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TDR 3 Series 3 Watt
Input Specifications
Input current at no load (nominal input voltage) 5 Vin models: 50 mA typ.
12 Vin models: 30 mA typ.
24 Vin models: 13 mA typ.
48 Vin models: 10 mA typ.
Input current at full load (nominal input voltage) 5 Vin models: 790 mA typ.
12 Vin models: 320 mA typ.
24 Vin models: 160 mA typ.
48 Vin models: 80 mA typ.
Surge voltage (1 s max.) 5 Vin models: 15 V max.
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
EMC emissions EN 55032 class A/B (with external components)
– Application note for filter class A/B proposal www.tracopower.com/overview/tdr3
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3 10 V/m, perf. criteria A
Fast transient / Surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
with external input capacitor e.g. Nippon
chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Power frequency magnetic field EN 61000-4-8, 100 A/m, perf. criteria A
Reflected ripple current 5 Vin models: 80 mAp-p typ.
(measured with input filter according class A) 12 Vin models: 40 mAp-p typ.
24 Vin models: 30 mAp-p typ.
48 Vin models: 20 mAp-p typ.
Output Specifications
Voltage set accuracy ±1 % max
Regulation – Input variation (Vin min. to Vin max.) 0.2 % max.
– Load variation (0 – 100 %) single output models: 1.0 % max.
dual output models: 1.0 % max. balanced load
– Load variation (10 – 90 %) single output models: 0.5 % max.
dual output models: 0.8 % max. balanced load
– Load cross regulation (25 / 100 %) 5.0 % max. (dual output models)
Minimum load 0 % of rated max. load
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz bandwidth) 30 mVp-p typ.
Start up time – Power On 5 ms typ.
(constant resistive load) – Remote On 5 ms typ.
Transient response setting time (25 % load step change) 250 µs typ.
Short circuit protection continuous, automatic recovery
Capacitive load 5 VDC models: 1680 µF max.
12 VDC models: 820 µF max.
15 VDC models: 680 µF max.
±12 VDC models: 470 µF max. (each output)