Embedded Power for Business-Critical Continuity Rev. 10.26.11_131 LCM600 Series 1 of 6 LCM600 600 Watts Bulk Front End Total Power: 600 W # of Outputs: Single Output: 3.3 to 60 V Optional 5.0 V standby Electrical Specifications Special Features * 600 W output power * Low Cost * 2.4" x 4.5" x 7.5" * 7.41 W/cu-in * Industrial/Medical safety * -40 C to 70 C with derating * Optional 5 V @ 2 A Housekeeping * High Efficiency: 89% typical * Variable speed "Smart Fans" * DSP controlled front end * Conformal coat option * 20% adjustment range * Margin programming * OR-ing FET * Terminal block input option Input Input range: 85 - 264 Vac (Operating) 115/230 Vac (Nominal) Input through standard IEC connector Frequency: 47 - 440 Hz, Nominal 50/60 Input fusing: Internal 10 A fuses, both lines fused Inrush current: Power factor: Harmonics: Input current: Hold up time: Efficiency: Leakage current: 25 A peak, either hot or cold start 0.99 typical, meets EN61000-3-2 Meets IEC 1000-3-2 requirements 8 A RMS max input current, at 100 Vac 20 ms minimum for Main O/P, at full rated load > 88% at full load < 0.3 mA at 264 Vac ON/OFF power switch: N/A Power line transient: Isolation: MOV directly after the fuse Compliance PRI-Chassis 2500 Vdc Basic PRI-SEC 2500 Vdc Reinforced SEC-Chassis 500 Vdc LCM600Q Efficiency Without the 5 Vsb and 24 V ORing FETS * EMI Class B * EN61000 Immunity 92.00 90.00 Safety * UL 60950-1 508/1598/1433 60601-1 * CSA 60950-1 * VDE 60950-1 60601 * China CCC * CB Scheme Report/Cert Efficiency % 88.00 86.00 100 Vac 230 Vac 84.00 82.00 80.00 78.00 76.00 25 50 75 Loading % 100 Embedded Power for Business-Critical Continuity Rev. 10.26.11_131 LCM600 Series 2 of 6 Output Output rating: See table 1 85 - 264 Vac Set point: Total regulation range: 0.5% 85 - 264 Vac Combined line/load/transient when measured at output terminal Main output 2% 5 Vsb 1% 600 W maximum Main output @ 0.0 A 5 Vsb @ 0.0 A 1% max p-p 50 mV max p-p Rated load: Minimum load: Output noise (PARD): Derate linear to 50% from 50 C to 70 C No loss of regulation Output voltage overshoot: Transient response: < 300 Sec Max units in parallel: Short circuit protection: Protected, no damage to occur Remote sense: Main output 5 Vsb output Measured with a 0.1 F Ceramic and 10 F Tantalum Capacitor on any output, 20 MHz No overshoot/undershoot outside the regulation band during on or off cycle 50% load step @ 1 A/s Step load valid between 10% to 100% of output rating Recovery time to within 1% of set point at onset of transient Up to 10 Bounce mode Compensation up to 500 mV Output isolation: Standard per safety requirements Forced load sharing: Overload protection (OCP): To within 10% of all shared outputs 105% to 125% 120% to 170% Overvoltage protection (OVP): 125% to 145% 110% to 125% Overtemp protection: 10 - 15 C above safe operating area Analog sharing control Main output 5 Vsb output 12 V output 5 Vsb output Both PFC and output converter monitored Environmental Specifications Operating temperature: -40 C to +70 C, linear derating to 50% from 50 C to 70 C Storage temperature: -40 C to +85 C Humidity: 20 to 90%, non-condensing. Operating. Conformal coat option available Fan noise: Altitude: < 45 dBA, 80% load at 30 C Operating - 15,000 feet Storage - 30,000 feet MIL-STD-810F 516.5, Procedure I, VI. Storage MIL-STD-810F 514.5, Cat. 4, 10. Storage Shock: Vibration: Ordering Information Current Model Number* Output Nominal Output Voltage Set Point Set Point Tolerance Adjustment Range Min Max Output Ripple P/P Power Max. Combined Line/ Load Regulation Status LCM600C LCM600E 3V 5V 3V 5V 0.5% 0.5% 2.0 - 4.0 V 4.0 - 6.0 V 0A 0A 150 A 120 A 50 mV 50 mV 600 W 600 W 2% 2% Coming Soon Coming Soon LCM600L 12 V 12 V 0.5% 9.6 - 14.4 V 0A 52 A 120 mV 600 W 2% Released LCM600N 15 V 15 V 0.5% 12.0 - 19.5 V 0A 44 A 150 mV 600 W 2% Coming Soon LCM600Q 24 V 24 V 0.5% 19.2 - 28.8 V 0A 27 A 240 mV 600 W 2% Released LCM600U 36 V 36 V 0.5% 28.8 - 43.2 V 0A 16.7 A 240 mV 600 W 2% Released LCM600W 48 V 48 V 0.5% 38.4 - 57.6 V 0A 14 A 280 mV 600 W 2% Released *Note: Add "-T" for terminal block instead of IEC input. Embedded Power for Business-Critical Continuity Rev. 10.26.11_131 LCM600 Series 3 of 6 Pin Assignment Signals Name Description Pin Number(s) +Vout Power rail SK4 GND Power GND SK5 Signals Name Description A2 EEPROM Address 1 -VPROG Return connection of external supply for Margin Programming 2 A1 EEPROM Address 3 -Vsense Remote Sense Return 4 ISHARE Load share voltage 5 A0 EEPROM Address 6 SDA1 Serial Data Signal (I2C) 7 +VPROG SCL1 +Vsense 5VSB GND 5VSB G_DCOK_C GPIOA6 Positive connection of external supply for Margin Programming Serial Clock Signal (I2C) Remote Sense Positive 5V standby 5V standby Return 5V standby Global DCOK Collector EEPROM Write Protect 8 9 10 11 12 13 14 15 G_DCOK_E Global DCOK Emitter (GND) 16 GND Return Ground for output signal and I2C communication 17 G_ACOK_C Global ACOK Collector 18 INH_EN Turn Off Main Output 19 G_ACOK_E Global ACOK Emitter (GND) 20 SK2 Pin Number Note: Mating connector for SK2 is LANDWIN CI0120P1HD0-LF PSU Front View Signal Output Signal Connectors (SK2) LED Indicators 2 provided are clearly visible up to a 45 degree offset from vertical with office environment ambient lighting. The status is reflected in the indicator color. The DC_OK LED is bicolor. It shall light green if the DC output is within specification, and amber if the output falls out of specification. The AC_OK LED is Green if the AC is within specification and off when out of specification. Note: With 5 V standby, Amber also indicates that PSU is in standby mode/output off. Control Signals AC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided. DC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided. PS_INHIBIT/ENABLE Signal 0.0 - 0.5 V contact closure, output OFF Embedded Power for Business-Critical Continuity Rev. 10.26.11_131 LCM600 Series 4 of 6 Mechanical Drawing - IEC Input Weight: 2.84 lbs (1.29 Kg) 3.5 REF 190.5 0.5 114.3 0.5 PN 4176621060X (PRNTG FRMT LCM600) PROVISION FOR FUTURE LABEL REQUIREMENTS AIRFLOW DIRECTION IEC320 AC INLET CONNECTORS LED (DC OK/FAIL) (8X) MOUNTING LOCATIONS AT THIS SIDE & OPPOSITE SIDE M4.0 X .7P THREAD 61.0 0.5 LED (AC OK) (2X) 47.0 0.5 (2X) 22.0 0.5 SK1 NEG (SK5) (2X) 6.0 0.5 POS (SK4) (2X) PN 39120205381 (SCREW-PP MC M3.5 X 6 W/ETW) FOR 24, 36, 48 V (4X) PN 39120205381 (SCREW-PP MC M3.5 X 6 W/ETW) FOR 3, 5, 12 & 15 V (2X) 10.0 0.5 (2X) 17.65 0.5 (2X) 182.5 0.5 (2X) 177.5 0.5 11.15 0.5 (2X) 94.45 0.5 (4X) MOUNTING LOCATIONS AT THIS SIDE M4.0 X .7P THREAD Embedded Power for Business-Critical Continuity Rev. 10.26.11_131 LCM600 Series 5 of 6 Mechanical Drawing - Terminal Block Input Weight: 2.84 lbs (1.29 Kg) 190.5 0.5 9.5 16.9 19.2 REF 9.5 GROUND 32.8 LIVE 12.8 114.3 0.5 NUETRAL PRODUCT LABEL LCM600Q-401 SCREW-MC PHILIP PAN WITH EXT-T WASHER M3.5 x P0.6 x 6 (15.75 ) (2X) 22 0.5 POS - SK4 NEG - SK5 SK2 SIGNAL CONNECTOR - 20 WAY (2X) 6 0.5 (2X)182.5 0.5 (2X)177.5 0.5 11.15 0.5 (2X) 94.45 0.5 (2X)10 0.5 17.65 0.5 LED (AC OK) (8X) MOUNTING LOCATIONS BOTH SIDES M4x0.7P THREAD 41.7 61 0.5 LED (DC/OK FAIL) AIRFLOW DIRECTION (2X) 47 0.5 INPUT TERMINAL BLOCK PROVISION FOR FUTURE LABEL REQUIREMENTS (4X) MOUNTING LOCATIONS M4x0.7P THREAD Embedded Power for Business-Critical Continuity Accessories Americas Rev. 10.26.11_131 LCM600 Series 6 of 6 PIN 20 PIN 19 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 PIN 2 PIN 3 PIN 1 Europe (UK) 300 5 mm Order kit part number 73-788-001 for control connector interface with .3m wires attached Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 PIN 20 PIN 19 Asia (HK) PIN 3 PIN 1 For global contact, visit: PIN 2 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 www.Emerson.com/EmbeddedPower techsupport.embeddedpower Order kit part number 73-788-002 for control connector interface with unloaded housing and 20 pins @emerson.com Miscellaneous Specifications Burn-In 100% Burn-in at 45 C, at 80 - 90 % load. Duration of burn-in determined by Quality Assurance Procedures MTBF While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6 specification @ 25 C and 40 C, ambient, at full load. With the power supply installed in a system in a 25 C ambient environment and operating at full load, capacitor life shall be 10 years, minimum for ALL electrolytic capacitors contained within this power supply. The power supply shall demonstrate a MTBF level of > 500,000 hours. Connectivity DC Power Embedded Computing Embedded Power Monitoring Quality Assurance Full QAV testing shall be conducted in accordance with Emerson Network Power Standards with reports available upon request. Warranty Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power shall warrant the power supply to be free of defects in materials and workmanship for a minimum period of three years from the date of shipment, when operated within specifications. The warranty shall be fully transferable to the end owner of the equipment powered by the supply. EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2011 Emerson Electric Co.