BURNDY Compression ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL DIE AND COLOR CODE INFORMATION BEVELED ENTRY INSPECTION WINDOW TYPES YA-L, YA-L-TC CRIMP COPPER COMPRESSION TERMINAL ELECTRO-TIN PLATED CABLE ACCOMMODATION C-9 B UL Listed 90 C, 600 Volts to 35 KV B 90 B T T T 45 L Fig. 1 Catalog Number YAV10-45-BOX YAV10-BOX YAV10R-BOX YAV10R3-BOX YAV10T2-BOX YAV10T3-45-BOX YAV10T3-BOX YAV10T4-BOX YA8CL1-BOX YA8CL1-45 YA8CL1-90 YA8CL2-BOX YA8CL2-45 YA8CL2-90 YA8CL3-BOX YA8CL3-45 YA8CL3-90 YA8CL4-BOX YA8CL4-45 YA8CL4-90 YA8CL-BOX YA8CL-45 YA8CL-90 YA6CL-BOX YA6CL-45 YA6CL-90 YA6CL1-BOX YA6CL1-45 YA6CL1-90 YA6CL3-BOX YA6CL3-45 YA6CL3-90 *** AWG Fig # 1 1 #14-#10 3 STR 3 1 #12-#10 2 SOL 1 1 1 2 3 1 2 #8 AWG 3 1 #8 WELD 2 3 37/24 1 2 #6 SOLID 3 1 2 3 1 2 3 1 2 #6 AWG 3 1 2 3 MM2 6 10 Tongue Width 8-10 .38 1/4 5/16 1/4 1/4 3/8 .47 .53 .47 .47 .56 Figure Dimensions (B) (T) .405 .058 .405 .058 .375 .058 .405 .047 .38 .047 .405 .047 .405 .047 .38 .047 1/4 .44 .44 .08 5/16 .52 .44 .06 3/8 .58 .44 .06 1/2 .71 .44 .05 8-10 .41 .44 .08 1/4 .45 .54 .08 8-10 .41 .41 .42 .54 .54 .54 .09 .09 .09 5/16 .52 .54 .07 * Use PUADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, PUADP-1 adapter not required. *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. Fig. 3 Fig. 2 Conductor Stud Hole Size L L Dieless (L) .92 1.02 .77 .83 1.12 1.10 1.10 1.18 1.26 1.24 .80 1.38 1.34 .92 1.51 1.45 1.04 1.76 1.67 1.28 1.16 1.16 .71 1.18 1.08 .81 .99 .89 .72 1.24 1.06 .93 (# of crimps) Y8MRB-1 (1) Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 - - - Y1MR (1) Y8MRB-1 (1) W8CVT (1) W8CVT (1) Y2MR (1) W8CRT (1) W8CRT (1) MY29-3 (1) X8CRT (1) X8CRT (1) MY29-11 (1) MRC840 (1) U8CRT (1) Red 49 7/16 Y1MR (1) W5CVT (1) W5CVT (1) MY29-3 (1) W5CRT (1) W5CRT (1) MY29-11 (1) X5CRT (1) X5CRT (1) MRC840 (1) X8CART (1) X8CART (1) Y2MR (1) U5CRT (1) Blue 7 7/8 The MM2 conductor size listed is for both Class 2 and Class 5 conductor. See tooling section of this catalog for complete tool and die listings. - Wire Color Die Strip Code Index Length 7/16 For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (Continued) T Catalog Number C-10 YA6CL4-BOX YA6CL4-45 YA6CL4-90 YA6CL6-BOX YA6CL6-45 YA6CL6-90 YA5CL-BOX YA5CL-45 YA5CL-90 YA4CL-BOX YA4CL-45 YA4CL-90 YA4CL1-BOX YA4CL1-45 YA4CL1-90 YA4CL3-BOX YA4CL3-45 YA4CL3-90 YA4CL4-BOX YA4CL4-45 YA4CL4-90 YA4CL6-BOX YA4CL6-45 YA4CL6-90 YA3CL YA3CL-45 YA3CL-90 YA2CL2-BOX YA2CL2-45 YA2CL2-90 YA2CL-BOX YA2CL-45 YA2CL-90 YA2CL4-BOX YA2CL4-45 YA2CL4-90 YA2CL6-BOX YA2CL6-45 YA2CL6-90 YA1CL2 YA1CL2-45 YA1CL2-90 YA1CL-BOX YA1CL-45 YA1CL-90 YA1CL4-BOX YA1CL4-45 YA1CL4-90 YA1CL6-BOX YA1CL6-45 YA1CL6-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG Stud Hole Size Tongue Width 3/8 .63 #6 AWG #5 AWG #4 AWG # 3 STR # 2 SOL #2 AWG #1 AWG 25 1/2 .75 1/4 .44 1/4 .50 8-10 .50 5/16 .58 3/8 .58 1/2 .71 5/16 .55 1/4 .61 5/16 .61 35 3/8 .61 1/2 .73 1/4 .68 5/16 .68 50 3/8 .68 1/2 .73 * Use PUADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, PUADP-1 adapter not required. T 45 L L Fig. 1 Fig. 2 Conductor *** MM2 B 90 B T Figure Dimensions (B) (T) (L) 1.28 .54 .06 1.17 1.05 1.60 .54 .12 1.54 1.30 1.65 .81 .07 1.31 .81 1.74 .81 .09 1.44 .84 1.58 .81 .09 1.28 .75 1.92 .81 .08 1.68 .96 1.92 .81 .08 1.68 1.08 2.20 .81 .06 2.02 1.32 1.88 .88 .09 1.76 .98 1.88 .88 .11 1.55 .89 1.93 .88 .11 1.62 1.01 2.06 .88 .11 1.74 1.14 2.32 .88 .09 2.17 1.37 1.81 .88 .10 1.70 .91 1.94 .88 .01 1.82 1.03 2.06 .88 .10 1.95 1.16 2.37 .88 .09 2.22 1.40 Dieless (# of crimps) L Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 W5CVT (1) W5CVT (1) Y1MR (1) W5CRT (1) W5CRT (1) MY29-3 (1) X5CRT (1) X5CRT (1) MY29-11 (1) X8CART (1) X8CART (1) MRC840 (1) Y2MR (1) W5CRT (1) W5CRT (1) W5CVT (1) X5CRT (1) X5CRT (1) W5CVT (1) W4CVT (1) W4CVT (1) W4CRT (1) W4CRT (1) X4CRT (1) X4CRT (1) Y1MR (2) MY29-3 (1) MY29-11 (1) MRC840 (1) Y2MR (2) W3CRT (1) W3CRT (1) Y644M (1) W2CVT (1) W2CVT (1) W2CRT (1) W2CRT (1) X2CRT (1) X2CRT (1) Y1MR (2) MY29-3 (1) W1CVT (1) W1CVT (1) MY29-11 (1) W1CRT-1 (1) W1CRT-1 (1) MRC840 (1) X1CRT-1 (1) X1CRT-1 (1) Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. Wire Color Die Strip Code Index Length U5CRT (1) UBCABT (1) Blue 7 7/8 U5CRT (1) Blue 7 7/8 U4CRT (1) U6CABT (1) Gray 8 7/8 U3CRT (1) White 9 15/16 U2CRT (1) Brown 10 15/16 U1CRT-1 (1) U4CABT (1) Green 11 15/16 For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (Continued) T Catalog Number YA25L2-BOX YA25L2-45 YA25L2-90 YA25L4-BOX YA25L4-45 YA25L4-90 YA25L6-BOX YA25L6-45 YA25L6-90 YA25L-BOX YA25L-45 YA25L-90 YA26L2-BOX YA26L2-45 YA26L2-90 YA26L3-BOX YA26L3-45 YA26L3-90 YA26L-BOX YA26L-45 YA26L-90 YA26L60 YA26L60-45 YA26L60-90 YA26L6-BOX YA26L6-45 YA26L6-90 YA26L7-BOX YA26L7-45 YA26L7-90 YA26LNT516 YA27L2-BOX YA27L2-45 YA27L2-90 YA27L3 YA27L3-45 YA27L3-90 YA27L4-BOX YA27L4-45 YA27L4-90 YA27L-BOX YA27L-45 YA27L-90 YA27LNT38 YA28L17-BOX YA28L17-45 YA28L17-90 YA28L2-BOX YA28L2-45 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 AWG Stud Hole Size Tongue Width 1/4 .75 3/8 .75 1/0 AWG 2/0 AWG 1/2 .75 5/16 .75 1/4 .83 5/16 .83 3/8 .83 70 3/4 .96 1/2 .83 5/8 .88 5/16 .62 1/4 1.00 5/16 .91 3/0 AWG 3/8 .91 1/2 .91 3/8 .76 5/8 1.02 4/0 AWG 1/4 * Use PUADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, PUADP-1 adapter not required. T 45 L L Fig. 1 Fig. 2 Conductor *** MM2 B 90 B T 1.02 Figure Dimensions (B) (T) (L) 1.84 .88 .12 1.76 .94 2.09 .88 .12 2.01 1.19 2.34 .88 .12 2.26 1.44 1.96 .88 .12 1.88 1.07 1.94 .94 .12 1.78 .96 2.06 .94 .12 1.91 1.09 2.19 .94 .12 2.03 1.21 2.96 .94 .12 2.77 1.89 2.44 .94 .12 2.28 1.46 2.69 .94 .11 2.50 1.71 .94 .13 2.62 2.04 1.00 .13 1.91 .99 2.16 1.00 .13 2.03 1.12 2.29 1.00 .13 1.91 .99 2.54 1.00 .13 2.41 1.49 1.00 .12 2.71 .88 .14 2.64 1.79 1.96 .88 .14 1.89 Dieless (# of crimps) MY29-3 (1) MY29-11 (1) MRC840 (2) Y644M (1) L Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length W25VT (2) W25VT (2) W25RT (2) W25RT (2) X25RT (2) X25RT (2) U25RT (1) U2CABT (1) Pink 12 15/16 W26VT (2) W26VT (2) W26RT (2) W26RT (2) X26RT (2) X26RT (2) U26RT (1) Black 13 1 W27VT (2) W27VT (2) W27RT (2) W27RT (2) X27RT (3) X27RT (3) U27RT (1) Orange 14 1-1/16 W28VT (2) W28VT (2) W28RT (2) W28RT (2) X28RT (3) X28RT (3) U28RT (1) Purple 15 *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. 1-1/8 For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. C-11 BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (Continued) T C-12 Catalog Number YA28L2-90 YA28L3-BOX YA28L3-45 YA28L3-90 YA28L4-BOX YA28L4-45 YA28L4-90 YA28L56-BOX YA28L56-45 YA28L56-90 YA28L-BOX YA28L-45 YA28L-90 YA28LNT38 YA29L2 YA29L2-45 YA29L2-90 YA29L4 YA29L4-45 YA29L4-90 YA29L7 YA29L7-45 YA29L7-90 YA29LTC78 YA29LTC78-45 YA29LTC78-90 YA29LNT38 YA29L-BOX YA29L-45 YA29L-90 YA30L YA30L-45 YA30L-90 YA30L1 YA30L1-45 YA30L1-90 YA30L24 YA30L24-45 YA30L24-90 YA30L27 YA30L27-45 YA30L27-90 YA30L28 YA30L7 YA30L7-45 YA30L7-90 YA31L YA31L-45 YA31L-90 Fig # AWG 3 1 2 3 1 2 3 4/0 AWG 1 2 3 1 2 3 1 1 2 3 1 2 3 1 2 250 kcmil 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 2 3 1 2 3 300 kcmil 350 kcmil 150 185 Stud Hole Size 1/4 Tongue Width 1.02 5/16 1.02 3/8 1.02 3/4 1.05 1/2 1.02 3/8 .76 1/4 1.11 3/8 1.11 5/16 1.11 7/8 1.11 3/8 .96 1/2 1.11 1/2 1.20 5/16 1.20 3/8 1.20 7/8 1.20 3/4 1.20 5/8 1.20 1/2 1.29 * Use PUADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, PUADP-1 adapter not required. T 45 L L Fig. 1 Fig. 2 Conductor *** MM2 B 90 B T Figure Dimensions (B) (T) (L) .88 .14 1.04 2.08 .88 .14 2.01 1.16 2.21 .88 .14 2.14 1.29 2.90 .88 .13 2.81 1.97 2.46 .88 .14 2.39 1.54 .88 .16 2.79 2.17 1.06 .16 2.07 1.08 2.42 1.06 .16 2.32 1.33 2.30 1.06 .16 2.20 1.20 3.36 1.06 .14 3.23 2.26 1.06 .16 2.96 2.67 1.06 .16 2.57 1.58 2.69 1.03 .16 2.60 1.61 2.31 1.03 .16 2.22 1.24 2.44 1.03 .16 2.35 1.36 3.37 1.03 .16 3.29 2.30 1.03 .16 3.12 2.94 1.03 .16 2.85 1.86 2.75 1.06 .18 2.75 1.65 Dieless (# of crimps) L Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length MY29-3 (1) W28VT (2) W28VT (2) MY29-11 (1) W28RT (2) W28RT (2) MRC840 (2) X28RT (2) X28RT (3) Y644M (1) U28RT (1) Purple 15 1-1/8 MY29-3 (1) W29VT (2) MY29-11 (1) X29RT (4) Y644M (1) W29VT (2) W29RT (2) X29RT (4) U29RT (1) Yellow 16 1-1/8 W30VT (2) W30VT (2) W30RT (2) U30RT (2) U28ART (2) White 17 1-1/16 W31VT (2) W31VT (2) W31RT (2) U31RT (2) U29ART (2) Red 18 1-3/16 Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (Continued) T Catalog Number YA31L11 YA31L11-45 YA31L11-90 YA31L36 YA31L36-45 YA31L36-90 YA31L7 YA31L7-45 YA31L7-90 YA31LNT38 YA32L YA32L-45 YA32L-90 YA32L1 YA32L1-45 YA32L1-90 YA32L14 YA32L14-45 YA32L14-90 YA32LTC78 YA32LTC78-45 YA32LTC78-90 YA33L YA33L-45 YA33L-90 YA34L YA34L-45 YA34L-90 YA34L20 YA34L20-45 YA34L20-90 YA34L37 YA34L37-45 YA34L37-90 YA34L6 YA34L6-45 YA34L6-90 YA34L8 YA34L8-45 YA34L8-90 YA34L9 YA34L9-45 YA34L9-90 YA35L YA35L-45 YA35L-90 YA36L11 YA36L YA36L-45 YA36L-90 Fig # AWG 1 2 3 1 2 350 kcmil 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 2 3 185 Stud Hole Size Tongue Width 3/8 1.29 7/8 1.29 5/8 1.29 3/8 96 5/8 1.38 1/2 1.40 400 kcmil 450 kcmil 500 kcmil 600 kcmil 3/8 1.38 7/8 1.40 5/8 1.48 5/8 1.55 1 1.55 3/8 1.55 240 550 kcmil 300 T 45 L L Fig. 1 Fig. 2 Conductor *** MM2 B 90 B T 1/2 1.55 3/4 1.55 7/8 1.55 5/8 1.65 1/2 1.74 5/8 1.74 * Use PUADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, PUADP-1 adapter not required. Figure Dimensions (B) (T) (L) 2.50 1.06 .18 2.42 1.40 4.02 1.06 .18 4.02 3.94 3.00 1.06 .18 3.00 1.90 1.06 .18 3.37 3.18 1.19 .19 3.08 1.95 2.93 1.19 .19 2.83 1.70 2.68 1.19 .19 2.58 1.45 3.62 1.19 .19 3.52 2.38 3.57 1.50 .21 3.30 2.00 3.37 1.27 .23 3.30 2.03 4.05 1.27 .23 3.99 2.72 2.87 1.27 .23 2.80 1.53 3.12 1.27 .23 3.05 1.78 3.55 1.27 .23 3.49 2.22 3.80 1.27 .23 3.74 2.47 3.81 1.69 .25 3.67 2.08 1.38 .27 3.29 3.72 1.38 .27 3.51 2.11 Dieless (# of crimps) L Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length C-13 W31VT (2) W31VT (2) W31RT (2) U31RT (2) U29ART (2) Red 18 1-3/16 W32VT (2) W32VT (2) W32RT (2) U32RT (2) U30ART (2) Blue 19 W33VT (2) W33VT (2) W33RT (2) U33RT (2) Gray 326 1-9/16 W34VT (2) W34VT (2) W34RT (2) U34RT (2) U31ART (2) Brown 20 1-7/16 - - U35RT (2) Yellow 21 1-3/4 - - U36RT (2) Green 22 1-3/4 1-1/4 Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (Continued) T Fig # 1 2 3 1 2 3 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 Stud Hole Size Tongue Width 600 kcmil 300 7/8 1.74 650 kcmil 5/8 1.80 700 kcmil 5/8 1.84 5/8 1.91 7/8 1.91 750 kcmil 1-1/4 1.91 3/8 1.12 1/2 1.91 5/8 1.98 5/8 2.01 5/8 2.19 1/2 1 2.49 2.19 1250 kcmil 3/4 2.46 1300 kcmil 3/4 2.53 1500 kcmil 3/4 2.69 1750 kcmil 3/4 2.90 2000 kcmil 3/4 3.10 800 kcmil 400 850 kcmil 1000 kcmil 500 * Use PUADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, PUADP-1 adapter not required. T 45 L L Fig. 1 Fig. 2 Conductor Catalog Number C-14 YA36LTC78 YA36LTC78-45 YA36LTC78-90 YA37L YA37L-45 YA37L-90 YA37L1 YA38L YA38L-90 YA38L-45 YA39L YA39L-45 YA39L-90 YA39L2 YA39L2-45 YA39L2-90 YA39L9 YA39L9-45 YA39L9-90 YA39LNT38 YA39L6 YA39L6-45 YA39L6-90 YA40L YA40L-45 YA40L-90 YA41L YA41L-45 YA41L-90 YA44L YA44L-45 YA44L-90 YA44L2 YA44L23 YA-45L YA-45L-45 YA-45L-90 YA-453L YA-453L-45 YA-453L-90 YA46L YA46L-45 YA46L-90 YA47L YA47L-45 YA47L-90 YA48L YA48L-45 YA48L-90 B 90 B T Figure Dimensions (B) (T) (L) 3.97 1.38 .27 3.95 2.55 3.57 3.55 1.39 .27 2.14 3.76 3.66 1.45 .27 3.60 2.15 3.67 1.42 .27 3.61 2.17 4.10 1.42 .27 4.05 2.61 4.85 1.42 .27 4.80 3.36 1.42 .27 4.70 3.41 1.42 .27 3.36 1.92 3.81 1.42 .30 3.69 2.21 4.15 1.88 .31 4.03 2.23 4.04 1.65 .33 4.01 2.32 1.65 .33 3.98 1.65 .33 4.73 4.68 2.00 .38 4.64 2.62 4.71 2.00 .39 4.68 2.65 4.78 2.00 .40 4.75 2.71 5.05 2.19 .42 5.00 2.79 5.19 2.25 .46 5.19 2.89 Dieless (# of crimps) Y644M (1) L Fig. 3 Installation Tooling Mechanical Hydraulic MD6, OUR840, BCT500HS, Y35,Y39,Y750, MD7-34R Y500CTHS Y46*, PAT750 Wire Color Die Strip Code Index Length - - U36RT (2) U32ART (2) Green 22 1-3/4 - - U37RT (2) Orange 23 1-15/16 - - U38RT (2) Pink 400 1-15/16 - - U39RT (2) P39RT (2) ** Black 24 1-15/16 - - P40RT(3) ** Orange 25 1-15/16 - - - Gold 26 1-15/16 - - P44RT(3) ** White 27 1-15/16 - - P45RT(3) ** Yellow 29 2-1/16 - - - Orange 30 2-1/16 - - P46RT (3) ** - Green 31 2-1/16 Gray 33 2-1/4 Brown 34 2-1/4 *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions.