50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
1 / 7
LWC050 Series
*Product images are for illustrative purposes
only and may vary from actual design.
Features
Power Rating: 50W
Input Voltage: 100-277Vac
Constant current design
Fixed output current(350mA-4170mA)
Efficiency to 91%
Dimmable with 0-10V dimming(optional)
UL Class 2(some models)
SCP, OTP, and OVP
IP67
5-year warranty
Surge Immunity: 4kV contact discharge (6kV optional)
Sign Components Manual (SAM)
Application
Indoor and outdoor applications
Model List*(See part number scheme for model number details)
(X=Dimming options: 0=Non-dimming, 2=2-wire dimming, 3=3-wire dimming)
Technical Data
Model Number
Input
Voltage Range
Output
Power
Output
Voltage
Output
Current Min.
Output
Current Max.
Power Factor
(277V)
LWC050-035S14XT
100~277Vac
50W
93-143V
350mA
350mA
0.9
LWC050-045S14XT
100~277Vac
50W
72-111V
450mA
450mA
0.9
LWC050-054S14XT
100~277Vac
50W
60-93V
540mA
540mA
0.9
LWC050-070S14XT
100~277Vac
50W
46-71V
700mA
700mA
0.9
LWC050-105S34XT*
100~277Vac
50W
31-48V
1050mA
1050mA
0.9
LWC050-140S24XT**
100~277Vac
50W
23-36V
1400mA
1400mA
0.9
LWC050-167S24XT**
100~277Vac
50W
20-30V
1670mA
1670mA
0.9
LWC050-210S24XT**
100~277Vac
50W
16-24V
2100mA
2100mA
0.9
LWC050-240S24XT**
100~277Vac
50W
14-21V
2400mA
2400mA
0.9
LWC050-280S24XT**
100~277Vac
50W
12-18V
2800mA
2800mA
0.9
LWC050-333S24XT**
100~277Vac
50W
10-15V
3330mA
3330mA
0.9
LWC050-417S24XT**
100~277Vac
50W
8-12V
4170mA
4170mA
0.9
Load Regulation
±5%
Line Regulation
±2%
Current range
±5%
Turn-on Delay time
2 sec. (Typ.) Measured at 110Vac input. / 1 sec. (Typ.) Measured at 220Vac input
Ripple & Noise (pk-pk)
3% Vo Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF
ceramic capacitor and a 10 uF electrolytic capacitor
Input voltage range
100~277Vac
50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
2 / 7
LWC050 Series
Technical Data(cont.)
Notes:
1. Unless specified, all the test results are measured in the 25°C ambient temperature.
2. *Class 2 Output (US & Canada).
3. **Class 2 Output (US)
4. Power factor minimum at 70% load
Safety Compliance
Frequency
50~63Hz
Inrush current
75A at 230Vac input, 25°C Cold Start
AC Current (Typ.)
0.56A measured at full load and 100Vac input / 0.25 measured at full load and 220Vac input
THD
< 20% measured at 100-277 Vac, from 75% to 100% Load
Leakage current
0.25 mA Measured at 277Vac 60Hz Input
Short circuit protection
Protection type: hiccup mode, recovers automatically after fault condition is removed
Over temperature
protection
110°C Maximum temperature of components inside the case Auto recovers after cooling
(Optional)
Over voltage protection
Latch mode, recycle AC to restart
Operating temperature
-40 ~ 70°C
Storage temperature
-40 ~ 85°C
Maximum case
Temperature
90°C (See Mechanical Drawing for exact location)
Humidity operational
10% ~ 100%RH
Humidity storage
5% to 100%RH
MTBF
252,000 hours For 1400 mA output model, measured at 110V input, 80%Load and 25°C
ambient temperature (MIL-HDBK-217F)
Life rating
87,000 hours For 1400 mA output model, measured at 220V input, 80%Load and 45°C
ambient temperature
Length (L)
7.3” (185.9mm)
Width (W)
1.8” (46.2mm)
Height (H)
1.27” (32.3mm)
Weight
625g
Safety Standard
UL8750, Compliance to UL1012 UL1310. CAN/CSA-C22.2 No. 223, CSA-C22.2 No. 107.1, CSA-
C22.2 No. 250.0-13-12, EN61347.1, EN61347-2-13 and EN60529
EMI Conduction &
Radiation
Meet EN55015 FCC Part 15 Class B
EMS Immunity
EN 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN
61000-4-6, EN 61000-4-8, EN 61000-4-11, EN 61547
Surge
EN61000-4-2 4kV contact discharge (6kV optional available)
50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
3 / 7
LWC050 Series
Dimming
The Dimmer control may be operated from a potentiometer, an input signal of 0 10 Vdc or a PWM signal.
Notes:
1. If the dimming function is not used, please open the yellow, purple and grey.
2. Io is actually output current and Ir is rated current without dimming.
3. Do not connect the dimming return to the output; otherwise the driver will not work normally.
Parameter
Min.
Typ.
Max.
10V output voltage
9.8V
10V
10.2V
10V output source current
0mA
-
10mA
Voltage on the 0-10v input pin
500mV
-
12V
Source current on 0-10V input pin
0mA
-
1mA
50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
4 / 7
LWC050 Series
Power Factor vs Load
Lifetime vs Case Temperature
50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
5 / 7
LWC050 Series
Efficiency vs Load
Derating Curve
Output Power
Efficiency
50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
6 / 7
LWC050 Series
Mechanical Diagram Non-Dimming
Mechanical Diagram Dimming
50W, 100-277Vac Input, Constant Current LED Driver
Technical Sales / Customer Service: +1-818-338-7788 • Email: sales@autec.com
31328 Via Colinas Suite 102 Westlake Village, CA 91362 USA www.autec.com
7 / 7
LWC050 Series
*Product images are for illustrative purposes only and may vary from actual design.
*Specifications are subject to change without notice. Autec is not responsible for issues arising from errors or
omissions.
X=Dimming options
0=Non dimming
2=2-wire dimming 0-10V
3=3-wire dimming 0-10V
Part Number Scheme
L W C 050-XXX S X 4 X T
L=LED Driver Series
C=Constant current
X=Output class
1=Non Class 2
2=Class 2 US & Canada
3=Class 2 US only
S=Single Output
050=Output Power(Watts)
W=Input Voltage100-277Vac
120VAC
XXX=Rated Current
Ex.) 035=350mA
417=4170mA
Surge Protection
4=4kv(standard)
6=6kv(optional)
T=Thermal Switch
Blank=no thermal
protection