pwC-12 1 2 Wa t t S i n g l e Output AC to DC Switching Power Supplies series 12 Watts Output Power 3.3Volts(DC) to 48Volts(DC) Single Outputs Universal Input 3,000VAC Input to Output Isolation EN55022 Class B EMI Model Number Output Voltage PWC12-3.3,S,E PWC12-5,S,E PWC12-9,S,E PWC12-12,S,E PWC12-15,S,E PWC12-24,S,E PWC12-48,S,E 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC 48 VDC WWW.ASTRODYNE.COM Output Amps 3.01 2.4 1.34 1.0 0.8 0.5 0.25 Ripple & Noise 50mV pk-pk 50mV pk-pk 75mV pk-pk 120mV pk-pk 120mV pk-pk 200mV pk-pk 200mV pk-pk Efficiency(Min) 70% 72% 75% 75% 75% 77% 77% Efficiency(Nom) 72% 75% 78% 80% 80% 82% 82% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 2 Wa t t S i n g l e Output AC to DC Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Input Frequency Input Current Inrush Current (cold start/25C) Power Consumption Leakage Current 115-240VAC nom 90-264VAC max 47-63 Hz 0.4 Amps max @ 90VAC 0.2 Amps max @ 264VAC 20A @ 115VAC / 40A @ 230VAC <0.5W @ 240VAC with no load <0.25mAmps @ 264VAC, 50Hz OUTPUT SPECIFICATIONS Output Voltage/Current (Note 2) Preset Accuracy (Note 5) Load Regulation (Note 3) Line Regulation (Note 4) Ripple/Noise (Note 1,6) Over Voltage Protection Hold Up Time Short Circuit Protection Over Current Protection Turn On Delay Time Rise Time Over Shoot and Under Shoot See Selection Chart 1.5%, typ: 3.3Volts(DC) 1%, typ 5~48Volts(DC) 1% max 0.5% max See Selection Chart Clamp 16mS, typ Latching, Recovering Latching, Recovering < 4S from AC From 0Volts(DC), <20mS @11VAC < 10% nom GENERAL SPECIFICATIONS Hi-pot Test Insulation Resistance Switching Frequency Efficiency Safety 3000VAC, 60S between I/P O/P 500Volts(DC), 1S between I/P O/P 20M 100 KHz, fixed, typ See Selection Chart UL/C-UL: UL60950-1 TUV: EN60950 All specifications are typical at nominal input, full load, and 25C unless otherwise noted WWW.ASTRODYNE.COM EMI EMS Burn-in Vibration Test Drop-Test pwC-12 series CSA: C22.2 60950-1-03 CB: IEC 60950-1: 2001 CE: EN 60601-1-2 CISPR EN55022B 61000-4-2;3;4;5;6;11 100%Burn-in with 80~100% loading & 30~40C Environment temperature 2G'S, 10~500Hz, 3axes, after 30min test no abnormally to be found 70cm, after drop test no function abnormally to be noted ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Relative Humidity Storage Temperature MTBF -20 to 70C nom input voltage range and free-air convection cooling See Derate Curves 0-95% -40 to +85C 564MHrs MIL-HDBK-217F(25C) PHYSICAL SPECIFICATIONS Weight SIze Open Frame Encapsulated SIP Open Frame & SIP 1.0 oz (29g) Encapsulated: 1.94 oz. (55g) 50.8x25.4x17.0 mm (2.0"x1.0"x0.67") 52.4x27.2x23 mm (2.06"x1.07"x0.91") 50.8x28.5x17 mm (2.0"x1.12"x0.67") Notes 1.Ripple & Noise dependent upon output voltage as specified per particular model. 2.Minimum load is NOT required for proper operation. 3. Load regulation is measured from 20% ti FL. 4. Line regulation is measured from 90VAC to 264VAC. 5. Preset accuracy measured at nominal load, 115VAC input. 6. O/P noise measured at directly at pins at max. load, with a 0.1uF/ceramic capacitor bypass, pk-pk @ 20MHz bandwidth. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 2 Wa t t S i n g l e Output AC to DC Switching Power Supplies pwC-12 series MECHANICAL SPECIFICATIONS - PWC12 Open Frame WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 2 Wa t t S i n g l e Output AC to DC Switching Power Supplies pwC-12 series MECHANICAL SPECIFICATIONS - PWC12 SIP STYLE WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 2 Wa t t S i n g l e Output AC to DC Switching Power Supplies pwC-12 series MECHANICAL SPECIFICATIONS - PWC12 Encapsulated Ambient (C) WWW.ASTRODYNE.COM Ambient (C) ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 2 Wa t t S i n g l e Output AC to DC Switching Power Supplies pwC-12 series derate curve C WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458