12 Watt Single Output AC to DC Switching Power Supplies PWC-12 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
12 Watts Output Power
3.3Volts(DC) to 48Volts(DC) Single Outputs
Universal Input
3,000VAC Input to Output Isolation
EN55022 Class B EMI
Model Number Output Voltage Output Amps Ripple & Noise Efficiency(Min) Efficiency(Nom)
PWC12-3.3,S,E 3.3 VDC 3.01 50mV pk-pk 70% 72%
PWC12-5,S,E 5 VDC 2.4 50mV pk-pk 72% 75%
PWC12-9,S,E 9 VDC 1.34 75mV pk-pk 75% 78%
PWC12-12,S,E 12 VDC 1.0 120mV pk-pk 75% 80%
PWC12-15,S,E 15 VDC 0.8 120mV pk-pk 75% 80%
PWC12-24,S,E 24 VDC 0.5 200mV pk-pk 77% 82%
PWC12-48,S,E 48 VDC 0.25 200mV pk-pk 77% 82%
12 Watt Single Output AC to DC Switching Power Supplies PWC-12 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
INPUT SPECIFICATIONS
Input Voltage 115-240VAC nom
90-264VAC max
Input Frequency 47-63 Hz
Input Current 0.4 Amps max @ 90VAC
0.2 Amps max @ 264VAC
Inrush Current (cold start/25°C) 20A @ 115VAC / 40A @ 230VAC
Power Consumption <0.5W @ 240VAC with no load
Leakage Current <0.25mAmps @ 264VAC, 50Hz
OUTPUT SPECIFICATIONS
Output Voltage/Current (Note 2) See Selection Chart
Preset Accuracy (Note 5) 1.5%, typ: 3.3Volts(DC)
1%, typ 5~48Volts(DC)
Load Regulation (Note 3) 1% max
Line Regulation (Note 4) 0.5% max
Ripple/Noise (Note 1,6) See Selection Chart
Over Voltage Protection Clamp
Hold Up Time 16mS, typ
Short Circuit Protection Latching, Recovering
Over Current Protection Latching, Recovering
Turn On Delay Time < 4S from AC
Rise Time From 0Volts(DC), <20mS @11VAC
Over Shoot and Under Shoot < 10% nom
GENERAL SPECIFICATIONS
Hi-pot Test 3000VAC, 60S between I/P O/P
Insulation Resistance 500Volts(DC), 1S between I/P O/P
≥20M
Switching Frequency 100 KHz, fixed, typ
Efficiency See Selection Chart
Safety UL/C-UL: UL60950-1
TUV: EN60950
CSA: C22.2 60950-1-03
CB: IEC 60950-1: 2001
CE: EN 60601-1-2
EMI CISPR EN55022B
EMS 61000-4-2;3;4;5;6;11
Burn-in 100%Burn-in with 80~100% loading &
30~40°C Environment temperature
Vibration Test 2G’S, 10~500Hz, 3axes, after 30min
test no abnormally to be found
Drop-Test 70cm, after drop test no function
abnormally to be noted
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -20 to 70°C nom input voltage range
and free-air convection cooling
See Derate Curves
Relative Humidity 0-95%
Storage Temperature -40 to +85°C
MTBF 564MHrs MIL-HDBK-217F(25°C)
PHYSICAL SPECIFICATIONS
Weight Open Frame & SIP 1.0 oz (29g)
Encapsulated: 1.94 oz. (55g)
SIze Open Frame 50.8x25.4x17.0 mm (2.0”x1.0”x0.67”)
Encapsulated 52.4x27.2x23 mm (2.06”x1.07”x0.91”)
SIP 50.8x28.5x17 mm (2.0”x1.12”x0.67”)
NOTES
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
1.Ripple & Noise dependent upon output voltage as specified per par-
ticular model.
2.Minimum load is NOT required for proper operation.
3. Load regulation is measured from 20% ti FL.
4. Line regulation is measured from 90VAC to 264VAC.
5. Preset accuracy measured at nominal load, 115VAC input.
6. O/P noise measured at directly at pins at max. load, with a 0.1uF/ce-
ramic capacitor bypass, pk-pk @ 20MHz bandwidth.
12 Watt Single Output AC to DC Switching Power Supplies PWC-12 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
MECHANICAL SPECIFICATIONS - PWC12 OPEN FRAME
12 Watt Single Output AC to DC Switching Power Supplies PWC-12 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
MECHANICAL SPECIFICATIONS - PWC12 SIP STYLE
12 Watt Single Output AC to DC Switching Power Supplies PWC-12 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
MECHANICAL SPECIFICATIONS - PWC12 ENCAPSULATED
Ambient (°C)
Ambient (°C)
12 Watt Single Output AC to DC Switching Power Supplies PWC-12 series
WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
DERATE CURVE
°C