tfs70Q.doc Version 1.0 06.01.02
__________________________________________________________________________________
VI TELEFILTER Filter specification TFS 70 Q 1/3
__________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Vectron International, Inc.
Potsdamer Straße 18 267 Lowell Road
D 14 513 TELTOW / Germ any Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter. co m E-Mail: vti@vtinh. co m
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
1. Measurem ent condi ti on
Ambi ent tem perature TA: 23 °C
Input power level: 0 dBm (typ.) Max 10 dBm.
Terminat i ng i mpedances at fc: for input: 50
 0 pF.
for output: 50
 0 pF.
Package, pin connection and 50
matching network
see page 2
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFD 70 Q is the m inim um of the pass band attenuati on amin. The minim um of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and l ower frequencies at
the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference
frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature
range is not included in the production tolerance scheme.
Data typ. value tolerance / li m it
____________________________________________________________________________________________________________________________________________________________________________________________________________
Insertion lo ss (Ref erence level) ae20 dB max 22 dB
____________________________________________________________________________________________________________________________________________________________________________________________________________
Reference frequency fc at ambient temperat ure (fCAT) 70,00 MHz 70,0±0,3 MHz
____________________________________________________________________________________________________________________________________________________________________________________________________________
1 dB - band width 11,96 MHz
3 dB - band width 13,67 MHz
20 dB - band width 18,00 MHz
40 dB - band width 20,15 MHz
____________________________________________________________________________________________________________________________________________________________________________________________________________
Amplitude ripple (p-p): fc ... fc ± 5,6 MHz 0,2 dB max 1,0 dB
____________________________________________________________________________________________________________________________________________________________________________________________________________
Relative attenuation arel
fcfc ± 5,6 MHz - max 1 dB
fc ± 5,6 MHz fc ± 6, 5 MHz - max 3 dB
fc - 30 MHz fc - 11 MHz 55 dB m i n 40 dB
fc + 11 MHz fc + 30 MHz 50 dB m i n 40 dB
fc - 70 MHz fc - 30 MHz 60 dB -
fc + 30 MHz fc + 70 MHz 45 dB -
____________________________________________________________________________________________________________________________________________________________________________________________________________
Group delay 720 ns max 1,5 µs
____________________________________________________________________________________________________________________________________________________________________________________________________________
Group delay ripple (p-p): fc ... fc ± 7,5 MHz ± 15 ns ± max 20 ns
____________________________________________________________________________________________________________________________________________________________________________________________________________
Deviation from l i n ear phase (p-p): fc ... fc ± 7,5 MHz 2,3°
____________________________________________________________________________________________________________________________________________________________________________________________________________
Triple transit attenuation com pared to main signal 50 dB
____________________________________________________________________________________________________________________________________________________________________________________________________________
Input/Output return loss with matching network (S11/S22): 1,5/1,5 dB
____________________________________________________________________________________________________________________________________________________________________________________________________________
Crosstalk 56 dB
_________________________________________________________________________________________________________________________________________________________________________________________________________
Temperature coefficient of frequency ( Tcf ) -72 ppm/K
____________________________________________________________________________________________________________________________________________________________________________________________________________
Frequency deviation of fc over temperature fc(Hz) = Tcf(ppm /K) x (T - TA) x fCAT (MHz)
Operating temperature range - 25 °C ... + 80 °C
Storage temperature range - 40 °C ... + 85 °C
____________________________________________________________________________________________________________________________________________________________________________________________________________
Generated:
Checked/Approved:
tfs70Q.doc Version 1.0 06.01.02
__________________________________________________________________________________
VI TELEFILTER Filter specification TFS 70 Q 2/3
__________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Vectron International, Inc.
Potsdamer Straße 18 267 Lowell Road
D 14 513 TELTOW / Germ any Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter. co m E-Mail: vti@vtinh. co m
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
3. Package
tft L6
14 Input
1 Input RF Return
7 Output
8 Output RF Return
13 Package Ground
TFS 70 Q
49
1,2,6,7
72
Air reflow temperature conditions
tfs70Q.doc Version 1.0 06.01.02
__________________________________________________________________________________
VI TELEFILTER Filter specification TFS 70 Q 3/3
__________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Vectron International, Inc.
Potsdamer Straße 18 267 Lowell Road
D 14 513 TELTOW / Germ any Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter. co m E-Mail: vti@vtinh. co m
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
1st and 2nd air reflow profile
Name: pre-heating periods main-heating periods peak temperature
Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C
Time: 60 sec. - 90 sec. 20 sec. - 25 sec.
Chi p-mount ai r reflow profil e
tim e / sec.
temperature / °C
0
20
40
60
80
100
120
140
160
180
200
220
240
260
0 20 40 60 80 100 120 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec. temperature / °C time / sec. temperature / °C
0 23 140 160
10 34 150 161
20 46 160 164
30 60 170 170
40 80 180 180
50 103 190 205
60 121 195 230
70 134 200 255
80 143 205 230
90 150 210 205
100 154 215 180
110 156 220 165
120 158 230 140
130 159 240 120