REV. June 01, 2005 Page 1 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Applications
Differential and Common Mode filtering for DC-DC
converters with 48 V and 24 V input:
Telecommunications
Data communications
Distributed Power Solutions
Features
Maximum current 4 A
Maximum operating input voltage 80V
100V/50V 100ms transient withstand capability
Differential LC-filter stage
Surface mounted design
Small footprint – only 0.75 sq. in.
Low profile: 0.339” [8.61 mm] maximum
Low weight: 0.18 oz [5 g]
-40°C to 85°C ambient temperature range
No airflow required up to 3 A current @ 85°C
Enables Q
&& Family converter compliance with
EN55022 and FCC Class B requirements conducted
emissions
UL 60950 recognition in U.S. & Canada, and
DEMKO certification per IEC/EN 60950
RoHS compliant (Q4 2005)
Description
The F4804 Input Filter minimizes the conducted and radiated emissions generated by switch mode DC-DC
converters, and allows board designs utilizing Q
&& ™ Family converters to easily meet stringent Class B conducted
emissions requirements.
Using the F4804 filter as the primary power-conditioning device in front of any of the Q
&& ™ Family converters will
provide a “worry-free” EMI design. Unlike most available off-the-shelf filter modules, the F4804 contains, in
addition to common mode noise reduction components, a differential LC-filter stage, which guarantees compliance
with conducted noise standards in the whole frequency range from 150 kHz to 30 MHz, including fundamental
switching frequency and its harmonics. Test results show headroom of 15-20 dB for conducted noise quasi-peak
levels, in relation to Class B requirements; see Figs. 2-8.
F4804 filter is designed specifically for distributed power solutions in conjunction with Q
&& ™ Family DC-DC
converters. Low profile and small size (only 0.75 sq. in.) in a surface mount package helps the system designer
save real estate on the system board, and simplifies the layout.
A single F4804 filter can be used with multiple converters, and is capable of providing up to a nominal 4 A to the
converter input bus. It can provide up to 3 A at 85°C ambient with no airflow.
REV. June 01, 2005 Page 2 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Electrical Specifications
Conditions: TA=25ºC, No Airflow, Vin=48 Vdc, unless otherwise specified.
Parameter Notes Min Typ Max Units
Absolute Maximum Ratings
Input Voltage1 Continuous 0 100 Vdc
Operating Ambient Temperature -40 85 °C
Storage Temperature -55 125 °C
Electrical Characteristics
Operating Input Voltage Range1, 2 0 48 80 Vdc
Maximum Operating Current 85°C ambient, no airflow 3 3 Adc
85°C ambient, airflow 300 LFM [1.5 m/s] 4 Adc
Voltage Drop at Maximum Load 4 A 0.32 Vdc
Voltage Drop – Typical Application Loaded with Q48x30033 (3.3 V, 30 A) 4 0.16 Vdc
Efficiency at Typical Load Loaded with Q48x30033 (3.3 V, 30 A) 99.6 99.7 %
Conducted Noises, Quasi-Peak Level 5 Loaded with Q48x30033 (3.3 V, 30 A)
- Main frequency and low harmonics up
to 5 MHz 40 45 dBµV
- High frequencies up to 30 MHz 35 48 dBµV
Additional Notes:
1. Absolute maximum voltage and maximum operating voltage are for the filter itself; check maximum rating for corresponding
DC-DC converters. Filter will not be damaged with reversed input voltage.
2. Designed primarily for 48 V applications, filter can be used with both 48 V converters (operating range from 36 V to 72 V) and
24 V converters (operating range from 18 V to 36 V). Typical filter application schematic is shown on Fig. 1.
3. Maximum current at any ambient temperature without airflow can be calculated as Imax = [4 - 0.025*(Tamb-45)] A, with
constraint Imax 4 A.
4. Letter x denotes either T or S, i.e. filter module is loaded either with Q48T30033 through-hole or Q48S30033 surface
mounted converter.
5. Typical EMI plot for conducted emissions (with fully loaded Q48x30033 converter connected to the filter output, see
schematic Fig. 1) is shown on Fig. 2. Plot was taken by independent test laboratory TUV. TUV report confirms compliance
with Class B requirements according EN-55022 (CISPR-22) and FCC standards.
REV. June 01, 2005 Page 3 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Rload
Vin (+)
Vin (-)
ON/OFF
Vout (+)
Vout (-)
TRIM
SENSE (+)
SENSE (-)
QFamily
Converter
(Top View)
47uF
ceramic
C2
Cin
F4804
Vsource
++IN
-IN -OUT
+OUT
(Top View)
Input Filter
C1
+
Fig. 1: Typical F4804 application schematic with Q
&& Family converter (negative ON/OFF
logic). Values C1, C2 and Cin depend on the specific converter input and output voltage.
Fig. 2: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x30033 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 2200 pF, C2 = 3300 pF, Cin
= 47 µF.
REV. June 01, 2005 Page 4 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Fig. 3: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x30025 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 2200 pF, C2 = 3300 pF, Cin
= 47 µF.
REV. June 01, 2005 Page 5 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Fig. 4: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x30020 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 2200 pF, C2 = 3300 pF, Cin
= 47 µF.
REV. June 01, 2005 Page 6 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Fig. 5: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x30018 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 2200 pF, C2 = 3300 pF, Cin
= 47 µF.
REV. June 01, 2005 Page 7 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Fig. 6: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x30015 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 2200 pF, C2 = 3300 pF, Cin
= 47 µF.
REV. June 01, 2005 Page 8 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Fig. 7: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x15050 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 0 pF (not mounted), C2 =
1500 pF, Cin = 200 µF.
REV. June 01, 2005 Page 9 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Fig. 8: Conducted emissions plot (quasi-peak values: "x", average values: "+")
for Q48x08120 in conjunction with F4804 filter. Limits shown are for quasi-peak
(upper limit) and average (lower limit) values. C1 = 0 pF (not mounted), C2 =
1500 pF, Cin = 200 µF.
REV. June 01, 2005 Page 10 of 10 www.power-one.com
F4804 Input Filter Data Sheet
80Vdc @ 4A Output
di/dt
®
Physical Information (Actual size shown)
TOP VIEW
-IN
SIDE VIEW
+IN
-OUT
+OUT
Filter Part Numbering Ordering Information
Product
Series Input
Voltage Rated Load
Current Tape and Reel Environmental
F 48 04 - R G
Filter Module
80 V
4A
No letter Bulk
R Tape and Reel
G Green/RoHS
Compliant
Not populated Non-RoHS
Compliant
The example above describes P/N F4804-RG: 0-80 V input, 4 A @ 80 V output, tape and reel, and RoHS compliant.
Please consult factory regarding availability of a specific (including RoHS compliant) version.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
Pad/Pin Connections
Pad/Pin # Function
+IN Vin (+)
-IN Vin (-)
-OUT Vout (-)
+OUT Vout (+)
All dimensions are in inches [mm]
Connector Material: Copper
Connector Finish: Gold over Nickel
Converter Weight: 0.18 oz [5 g]
Recommended Surface-Mount Pads:
Min. 0.080” x 0.112” [2.03 x 2.84]