MG CONNECTOR
Contact
Tab-on terminal
Terminal (without tabs)
Terminal (with tabs)
1
MG connector is designed for connecting
copper magnetic wire and used in various
insulation coating.
Insertion of various magnetic wires is easy
and efficient, and MG connector provides
excellent electrical connection.
MG connector typical connection method
and kind
• No coating removing treatment in advance
• Stable connection
• Reliable electrical performance
Standards ––––––––––––––––––––––
0Recognized E70188
* Compliant with RoHS.
* Refer to "General Instruction and Notice when using
Terminals and Connectors" at the end of this catalog.
* Contact JST for details.
2
3.4
3
7.6
15.9
3.45
3
7.85
7.1
3
12.85
24.2
#187...for 0.5mm thick tabs
#250...for 0.8mm thick tabs
―
―
―
適用電線範囲(参考)
AWG #
27〜23
22〜20
19〜16
19〜16
30〜27
27〜23
22〜20
19〜17
Conductor O.D. (mm)
0.36〜0.57
0.64〜0.81
0.91〜1.29
0.91〜1.29
0.25〜0.36
0.36〜0.57
0.64〜0.81
0.91〜1.15
10,000
10,000
10,000
5,000
10,000
10,000
10,000
10,000
Material and Finish
Q´ty /reel
Copper alloy, copper-undercoated, tin-plated
Applicable wire (Reference)Model No.
Type
With tabs
Without tabs
Tin-plated
MGT-10T-187
MGT-15T-187
MGT-24T-187
* MGT-24T-250
* MGT-6TN
* MGT-10TN
* MGT-15TN
* MGT-24TN
SMG-21T
Contact
Crimping
machine
Crimp applicator with dies
AP-K2N MKS-L MK/SMG-21
MK/SMG-21-B
Crimp applicator Dies
APLMKSMG21
APLMKSMG21-B
Applicator
3.45
1.5
1.53.15
6
13.45
Model No. mm2AWG #
* SMG-21T 0.33〜0.83 22〜18
Material and Finish
Copper alloy, copper-undercoated, tin-plated
Applicable wire Insulation O.D.
(mm)
Q´ty /
reel
1.5〜2.9 6,000
5.5min
9min
5.2 min
7.6 min
9.5min
14 min
Name
Type 1
Type 2
Applicable terminal Material
MGT-10T-187
MGT-15T-187
MGT-24T-187
* MGT-6TN
* MGT-10TN
* MGT-15TN
* MGT-24TN
* MGT-24T-250
Glass filled engineering plastics
Type 1 Type 2
MG CONNECTOR
With tab/#187 With tab/#250 Without tab
RoHS compliance MGT-( )T-187 displays (SN) on a label.
Note: 1. The applicable wire size above serves as a basic guideline. Before use, performance of this connector must be tested with the wire and housing that is to be used.
2. *Marked products are not UL approved.
Note: 1. Contact JST for details.
2. *Marked products are not UL approved.
RoHS compliance
Note: *Marked product is not UL approved.
Terminal
Contact
Recommended housing