47
REED SWITCH
ORD213
Super Ultraminiature
J2R0012-38-22
GENERAL DESCRIPTION
The ORD213 is a small single-contact reed switch designed for general control of low-level
loads less than 24 V. The reed contacts are sealed within the glass tube within inert gas to maintain
contact reliability.
FEATURES
(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive
any influence from the external atmospheric environment.
(2) Quick response
(3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed
switches are suited to applications in radio frequency operation.
(4) Reed switches are compact and light weight.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become
proximity switches.
EXTERNAL DIMENSIONS (Unit: mm)
APPLICATIONS
l Automotive electronic devices
l Control equipment
l Communication equipment
l Measurement equipment
l Household appliances
n
n
n
n
35.8±0.3
MAX 7.0
MAX f1.8
f0.3
48
AT
50
10 20 30 40 50 60 100 120 140 160 180
AT
40
30
20
10
0
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
mW
l ORD213
n
Parameter
Pull-in Value (PI)
Drop-out Value (DO)
Contact resistance (CR)
Breakdown voltage
Insulation resistance
Electrostatic capacitance
Contact rating
Maximum switching voltage
Maximum switching current
Maximum carry current
Rated value
1040
1.0
0.1
0.3
Unit
AT
AT
mW
VDC
W
pF
VA
V
A
A
24 ( )
DC
AC
5min
200max
150min
109min
0.4max
(1) Drop-out Value vs. Pull-in Value (2) Contact resistance
(Measurement length: 22mm)
Cumulative frequency percent (%)
Drop-out Value
Pull-in Value Contact resistance
ELECTRICAL CHARACTERISTICS
49
0.4
0.3
0.2
0.1
0
pF
AT
DCV
400
300
200
100
0
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
10
10
10
11
10
12
10
13
10
14
W
ORD213 l
10 20 30 40 50 60
(DC 100V)
(3) Breakdown voltage (4) Insulation resistance
Cumulative frequency percent (%)
Breakdown voltage
Insulation resistance
Pull-in Value
AT
10 20 30 40 50 60
Pull-in Value
(1MHz)
(5) Electrostatic capacitance
Electrostatic capacitance
50
AT
ms
0.5
0.4
0.3
0.2
0.1
0
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0ms
15
10
5
0
µs
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1 Hz
l ORD213
10 20 30 40 50 0.1 0.2 0.3 0.4
9000 10000 11000 12000


Parameter
Operate time
Bounce time
Release time
Resonant frequency
Maximum operating frequency
ms
ms
ms
Hz
Hz
0.3max
0.3max
0.05max
11000
±
2000
500
Rated value Unit
(1) Operate time (2) Bounce time
(25 Hz: 100AT energized)
(25Hz: 100AT energized)
Operate time
Cumulative frequency percent (%)
Pull-in Value Bounce time
(3) Release time (4) Resonant frequency
(25Hz: 100AT energized)
Release time
Cumulative frequency percent (%)
Resonant frequency
Drop-out Value
AT
10 20 30 40 50
nOPERATING CHARACTERISTICS
51
AT
mW
ORD213 l
60
50
40
30
20
10
0
200
150
100
PI
CR
DO
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
02468
10kg
40
30
20
10
0
10
20
30
40 20 0 20 40 60 80 100 120
CR
DO
PI
nMECHANICAL CHARACTERISTICS
(2) Lead tensile strength(1) Lead tensile test (static load)
(2.27kg-10sec)
Pull-in ValueDrop-out Value
Cumulative frequency percent (%)
Contact resistance
Breaking load
Before test After test
n
(1) Temperature characteristics
Rate of change percent
Temperature
ENVIRONMENTAL CHARACTERISTICS
52
(2) Temperature cycle (3) Temperature and humidity cycle
(4) High temperature storage test (5) Low temperature storage test
AT
mW
(-55°C to 125°C)
Before test After test Before test After test
Before test After test Before test After test
-10°C to 65°C
80% to 98%
60


50


40


30


20


10


0


200


150


100
Pull-in Value • Drop-out ValueContact resistancePull-in Value • Drop-out ValueContact resistance
Pull-in Value • Drop-out ValueContact resistance Pull-in Value • Drop-out ValueContact resistance
PI
CR
DO
AT
mW
60


50


40


30


20


10


0


200


150


100
PI
CR
DO
AT
mW
60


50


40


30


20


10


0


200


150


100
PI
CR
DO
AT
mW
lORD213
60


50


40


30


20


10


0


200


150


100
PI
CR
DO
(+125-500H) (-40℃-500H)
53
1500
1000
500
G
AT
mW
60
50
40
30
20
10
0
200
150
100
AT
PI
CR
DO
mW
ORD213 l
60
50
40
30
20
10
0
200
150
100
AT
PI
CR
DO
1002030405060
(6) Shock test
(7) Vibration test
2) Misoperation area
Pull-in Value • Drop-out Value
Acceleration
Misoperation
area
Contact resistancePull-in Value • Drop-out ValueContact resistance
Before test After test
Pull-in Value
Before test After test
(20G: 101000Hz)
(30G: 11ms)
1) Electrical characteristics
(openclose)
54
nLIFE EXPECTANCY DATA: ORD213
Load conditions
Voltage: 5VDC
Current: 100µA , 1mA , 5mA
Load: Resistive load
5
10
1
99.9
90
70
50
30
0.1
%
5mA 1mA 100 Am
l ORD213
No failure
Cumulative failure rate
Load conditions
Voltage: 12VDC
Current:
5mA , 10mA , 100mA
Load: Resistive load
Cumulative failure rate
Load conditions
Voltage: 24VDC
Current: 1mA , 10mA , 50mA
Load: Resistive load
Cumulative failure rate
Number of operations * Arrow indicates number
of operations where test
was completed.
50mA 10mA 1mA
No failure
10
99.9
90
70
50
30
0.1
%
Number of operations * Arrow indicates number
of operations where test
was completed.
100mA 10mA 5mA
No failure
10
99.9
90
70
50
30
0.1
%
Number of operations * Arrow indicates number
of operations where test
was completed.
0235710
5
23 5710
6
23 5710
7
23 5710
8
0235710
5
23 5710
6
23 5710
7
23 5710
8
0235710
5
23 5710
6
23 5710
7
23 5710
8