B R U S H L E S S D C M OTO R S * B L OW E R S * C O N T R O L L E R S WE'RE BIG ON BRUSHLESS TM ROTRON Technical Products Table of Contents Introduction ............................................... 1, 2, 3 BLDC Motors 1.7" (43mm) diameter ........................................... 4, 5 2.5" (64mm) diameter ........................................... 6, 7 3.0" (79mm) diameter ........................................... 8, 9 3.55" (90mm) diameter ....................................... 10, 11 3.9" (99mm) diameter ....................................... 12, 13 5.25" (133mm) diameter ..................................... 14, 15 Low Voltage Blowers (BLDC) 2.9" (74mm) ...................................................... 16, 17 3.0" (76mm) ....................................................... 18, 19 3.3" (84mm) ....................................................... 20, 21 4.5" (114mm) ..................................................... 22, 23 5.0" (127mm) MINIJAMMER (R)............................. 24, 25 5.1" (130mm) ..................................................... 26, 27 5.7" (145mm) WINDJAMMER (R)........................... 28, 29 High Voltage Blowers (BLDC) WINDJAMMER (R) 5.7" (145mm) Thru Flow/250 Watt/120VAC ..... 30, 31 5.7" (145mm) Bypass/250 Watt/120VAC .......... 32, 33 5.7" (145mm) Thru Flow//400 Watt/240 VAC ... 34, 35 5.7" (145mm) Bypass/400 Watt/240VAC .......... 36, 37 5.7" (145mm) Bypass/800 Watt/120VAC .......... 38, 39 5.7" (145mm) Bypass/1200 Watt/240VAC ........ 40, 41 Controllers (BLDC) 5 Amp Motor/Blower .......................................... 42 10 Amp Motor/Blower .......................................... 43 20 Amp Motor ...................................................... 44 BLDC Motor/Blower Controller Part Numbers ................................ 45 Blower/Motor Sizing Sheet ............................ 46 Application Engineering Basics ................................................. 47, 48, 49, 50, 51 AMETEK Global Locations ........................ 52, 53 Contact Information ....................................... 54 The AMETEK Electromechanical Group (EMG). . . is one of the world's largest producers of high-speed electric motor products for original equipment manufacturers (OEMs). In business since 1915, EMG uses its core competencies in motion and air movement products as engineered solutions for application-specific needs. A unit of AMETEK EMG, Rotron offers Brushless DC motor-, blower-, and controller-based solutions. The standard product lines of Rotron Technical Products cover a wide range of application demands. If there is a need for a product with unique performance, mounting, environment or agency requirements, Rotron can supply the solution. Whether a customer needs a standard or special design, Rotron has the solution for your application. AMETEK offers economies of scale that only can be accomplished by a company that produces more than 23 million motor products per year. With multiplant capability and flexibility, Rotron is positioned to support our customers' global programs. AMETEK Brushless DC Motors and Blowers are an ideal choice for such varied applications as medical instruments, robotics, pumps, compressors, business equipment, fans, machine tools, tape drives, or any other precise rotary motion/air delivery applications. 1 INTRO99 Brushless DC Motors. . . offer precise control for a wide range of applications. Rotron standard motor designs offer maximum controllable performance, coupled with the reliability of brushless technology in a compact cost effective package. First introduced in 1988, the AMETEK brushless DC motor product line has continually expanded into one of the largest mixes of fractional horsepower motor products in the industry. Motor Selection. . . is made easy with the wide variety of standard products available from AMETEK. Six different motor families are available in standard configurations. These include 1.7" (43mm), 2.5" (64mm), 3.0" (76mm), 3.55" (90mm), 3.9" (99mm), and 5.25" (133mm) diameter motors, with constant torque which range from 5.75 oz. in. (4.06 Ncm) to 832 oz. in. (5.87 Nm) and horsepower ratings of .014 to 1.75. Voltage options range from 12VDC to 74VDC. The table below provides a summary of the motor products, operating voltages, speed and torque ranges sorted by motor diameter. Use this chart to compare the AMETEK products to the application needs. Detailed motor information is provided on the individual product sheets. BLDC MOTORS Motor Diameter Operating Voltage (DC) Speed Range (RPM) Torque Range (oz. in.) Controller Input at Nom. Continuous Torque Maximum Continuous 1.7" (43mm) 12, 24, 36 0 - 3,000 5.75 - 11 2.5" (64mm) 12, 24, 36 0 - 5,000 14 - 69 3.0" (76mm) 13.8, 24, 27.6 0 - 4,930 19.7 - 55 3.55" (90mm) 12, 24, 36 0 - 4,300 22 - 132 3.9" (99mm) 12. 13.8, 27.6, 74 0 - 4,500 28 - 100 5.25" (133mm) 27, 27.6, 74 0 - 4,055 192 - 832 Motor Controllers All of the AMETEK BLDC Motors require a controller to operate. The controllers require a DC input which is processed into phase drive signals. The 1.7" (43mm) and 3.0" (76mm) motors are available with integrated controllers. All other motors require an external controller. Controller details and compatibility to the different motor products are supplied in the controller section of the catalog. 2 INTRO99 Brushless DC Blowers. . . offer variable (speed) output for a wide range of vacuum or pressure applications. Standard blower designs offer brushless DC motor drives coupled to high efficiency fan systems in a compact, cost effective package. Standard models are available in a wide range of input voltages, including 12, 24, 28, and 36VDC. A complete product line of brushless DC blowers that accepts line voltage input (120VAC and 240VAC) also is available. AMETEK brushless DC blowers are not designed for, and should not be used in, life sustaining applications. AMETEK brushless DC blowers are not 100% sealed and therefore should not be used with flammable or hazardous gases. Blower Selection. . . offers a wide variety of standard products available from AMETEK. Thirteen different blower families are available in standard configurations. These include seven low voltage and six high voltage products. The low voltage products provide outputs which range from 0 to 28" H20 (pressure) at flows of 0 to 45 CFM. The high voltage products provide outputs which range from 0 to 162" H20 (pressure) at flows of 0 to 275 CFM. LOW VOLTAGE PRODUCTS Blower Diameter In. H20 (Pressure) In. H20 (Vacuum) Operating Voltage (DC) CFM Range 2.9" (74mm) 12, 24 0-22 0-3 - 3" (76mm) 12, 24 0-18 0-10 - 3.3" (84mm) 12, 24 0-7 0-27 - 4.5" (114mm) 12, 24 0-9 0-28 - 5" (127mm) 12, 24 0-45 0-24 - 5.1" (130mm) 12, 24 0-15 0-25 - 5.7" (145mm) 12, 24, 36 0-39 0-28 0-28 Blower Diameter Operating Voltage (AC) CFM Range In. H20 (Pressure) 5.7" (145mm) 120 (250 Watt) 0-115 0-76 0-65 5.7" (145mm) 120 (800 Watt) 0-242 0-115 0-106 5.7" (145mm) 240 (400 Watt) 0-115 0-144 0-135 5.7" (145mm) 240 (1200 Watt) 0-275 0-162 0-118 HIGH VOLTAGE BYPASS PRODUCTS In. H20 (Vacuum) HIGH VOLTAGE THRU-FLOW PRODUCTS In. H20 (Pressure) In. H20 (Vacuum) Blower Diameter Operating Voltage (AC) CFM Range 5.7" (145mm) 120 (250 Watt) 0-117 0-75 0-70 5.7" (145mm) 240 (400 Watt) 0-67 0-50 0-47 3 INTRO99 1.7" (43mm) Diameter, 8 Pole, Brushless DC Motor Motor Data No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power, Max. Torque Constant Voltage Constant Electrical Time Constant Mechanical Time Constant Motor Constant Rotor Inertia Terminal Resistance Terminal Inductance Thermal Resistance Length ("L" above) Weight Shaft Length ("S" above) Unit of Measure 24 VDC Part Numbers RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts out oz.-in. /amp Ncm/amp V/kRPM V/rad/sec millisecond millisecond oz.-in./(watt^.5) Ncm/(watt^.5) oz.-in.sec2 Ncm-sec^2 ohms millihenry C/W inches mm lb. kg inches 119272* 4388 .16 12.7 8.96 5.75 4.06 2425 1.0 10 7.39 5.21 5.47 0.052 .273 .202 2.37 1.67 8.00 x 10-6 0.0565 9.74 2.66 3.5 1.864 47.35 .51 0.23 .75 119275* 4308 .18 51.3 36.20 11 7.77 3000 1.75 24 7.53 5.31 5.57 0.053 .339 .134 4.12 2.91 1.60 x 10-5 0.0113 3.34 1.13 1.90 2.614 66.40 .78 0.35 1.00 mm 19.05 25.40 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES * Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers. * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales. 4 1.7M99 1.7" (43mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 5 1.7M99 2.5" (64mm) Diameter, 8 Pole, Brushless DC Motor Motor Data No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power, Max. Torque Constant Voltage Constant Electrical Time Constant Mechanical Time Constant Motor Constant Rotor Inertia Terminal Resistance Terminal Inductance Thermal Resistance Length ("L" above) Weight Shaft Length ("S" above) Unit of Measure 24 VDC Part Numbers RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts out oz.-in. /amp Ncm/amp V/kRPM V/rad/sec millisecond millisecond oz.-in./(watt^.5) Ncm/(watt^.5) oz.-in.sec2 Ncm-sec^2 ohms millihenry C/W inches mm lb. kg inches 119000* 5947 1.14 142 100 14 10 4928 3.7 51 5.46 3.85 4.04 0.0385 0.838 5.236 6.8 4.8 0.0017 0.0012 0.648 0.543 1.26 2.335 59.31 1.15 0.52 .750 119001 5389 1.07 179 127 21 15 4234 4.6 66 6.02 4.25 4.45 0.0425 0.886 4.129 8.1 5.7 0.0019 0.0013 0.557 0.493 1.22 2.335 59.31 1.25 0.57 .750 119002 4233 0.93 191 135 27 19 3286 4.5 66 7.67 5.42 5.67 0.0542 0.937 4.080 9.3 6.6 0.0025 0.0018 0.678 0.635 1.19 2.835 72.01 1.60 0.73 .750 119003* 5468 1.08 267 189 34 24 4228 6.8 106 5.94 4.19 4.39 0.0419 0.904 3.775 10.1 7.1 0.0027 0.0019 0.348 0.314 1.15 2.835 72.01 1.75 0.79 .750 119004 4636 0.98 282 199 41 29 3455 6.8 105 7.00 4.94 5.18 0.0494 0.938 4.006 11.1 7.9 0.0035 0.0025 0.396 0.372 1.11 3.585 91.06 2.15 0.98 1.500 119005 4019 0.91 294 208 48 34 3074 6.8 109 8.08 5.70 5.97 0.0570 0.965 3.668 12.1 8.6 0.0038 0.0027 0.444 0.429 1.08 3.585 91.06 2.25 1.02 1.500 119006 3575 0.85 302 213 55 39 2645 6.9 108 9.08 6.41 6.71 0.0641 0.986 3.217 12.9 9.1 0.0038 0.0027 0.493 0.486 1.04 3.585 91.06 2.30 1.04 1.500 119007 3191 0.81 311 219 62 44 2290 6.9 105 10.17 7.18 7.52 0.0718 1.004 3.258 13.8 9.8 0.0044 0.0031 0.541 0.543 1.00 4.085 103.76 2.70 1.22 1.875 119008* 2879 0.77 319 225 69 49 2002 6.9 102 11.27 7.96 8.34 0.0796 1.019 3.021 14.7 10.4 0.0046 0.0032 0.589 0.601 0.96 4.085 103.76 2.80 1.27 1.875 mm 19.05 19.05 19.05 19.05 38.1 38.1 38.1 47.63 47.63 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES * Motors require brushless motor controller for operation, refer to the controller section ( page 45) for applicable controllers. * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales. 6 2.5M99 2.5" (64mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 7 2.5M99 3.0" (79mm) Diameter, 4 Pole, Brushless DC Motor This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron. Motor Data Voltage Input No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power Torque Constant Voltage Constant Length ("L" above) Weight Shaft Diameter ("D" above) Shaft Length ("S" above) Drive Electronics Electronic Drive Part Number Unit of Measure Volts DC RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts oz.-in. /amp Ncm/amp V/kRPM V/rad/sec inches mm lb. kg inches mm inches mm Internal or External Part Numbers 150004 13.8 3770 0.75 169 119 19.7 13.9 2927 4.6 43 4.90 3.46 3.66 0.035 3.25 82.63 1.7 0.776 .3152 8.0060 1.87 47.50 Internal *150007 27.6 5510 1 1300 915 43 30 4930 6.9 157 7.43 5.25 5 0.048 3.77 95.76 3 1.359 .281 7.137 3.50/3.50 88.90/88.90 External 48129-03 E-11488 24.0 5400 1.5 1298 917 55 39 4400 9.9 181 6.00 4.24 4.44 0.0424 4.27 108.46 TBD .281 7.137 1.37 34.75 External 48129-11 *Part Number 150007 has a dual shaft. NOTES * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 8 3.0M99 3.0" (79mm) Diameter, 4 Pole, Brushless DC Motor External Drive Part Number 48129-03 External Drive Part Number 48129-11 This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 9 3.0M99 3.55" (90mm) Diameter, 8 Pole, Brushless DC Motor Motor Data No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power, Max. Torque Constant Voltage Constant Electrical Time Constant Mechanical Time Constant Motor Constant Rotor Inertia Terminal Resistance Terminal Inductance Thermal Resistance Length ("L" above) Weight Shaft Length ("S" above) Unit of Measure RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts out oz.-in. /amp Ncm/amp V/kRPM V/rad/sec millisecond millisecond oz.-in./(watt^.5) Ncm/(watt^.5) oz.-in.sec2 Ncm-sec^2 ohms millihenry C/W inches mm lb. kg inches mm 24 VDC Part Numbers 119050* 4319 1.48 284 201 22 16 3715 4.4 60 7.52 5.31 5.56 0.0531 1.055 14.713 11.5 8.1 0.0138 0.0097 0.425 0.449 1.21 2.500 63.50 2.10 0.95 .750 19.05 119051 5259 1.74 375 265 36 25 4342 7.6 116 6.17 4.36 4.56 0.0436 1.052 13.065 12.5 8.9 0.0145 0.0102 0.242 0.255 1.19 2.500 63.50 2.25 1.02 .750 19.05 119052 4067 1.41 428 302 49 35 3265 7.6 118 7.98 5.64 5.90 0.0564 1.140 12.005 15.0 10.6 0.0191 0.0135 0.283 0.322 1.17 3.000 76.20 2.80 1.27 .750 19.05 119053* 3434 1.24 453 320 63 44 2641 7.9 123 9.45 6.68 6.99 0.0667 1.205 10.293 16.6 11.7 0.0201 0.0142 0.323 0.389 1.15 3.000 76.20 3.00 1.36 .750 19.05 119054 2838 1.07 496 350 77 54 2174 7.8 124 11.44 8.08 8.46 0.0808 1.256 11.253 19.0 13.4 0.0286 0.0202 0.363 0.457 1.13 3.750 95.25 3.75 1.70 1.500 38.10 119055 2543 0.99 505 357 91 64 1864 8.1 126 12.77 9.02 9.44 0.0901 1.297 10.283 20.1 14.2 0.0293 0.0207 0.404 0.524 1.11 3.750 95.25 4.00 1.81 1.500 38.10 119056 2281 0.92 518 366 105 74 1605 8.3 125 14.23 10.05 10.52 0.1005 1.331 9.413 21.4 15.1 0.0303 0.0214 0.444 0.591 1.09 3.750 95.25 4.20 1.90 1.500 38.10 119057 2021 0.85 541 382 119 84 1377 8.3 121 16.06 11.34 11.88 0.1134 1.358 9.313 23.1 16.3 0.0350 0.0247 0.485 0.658 1.06 4.250 107.95 4.70 2.13 1.875 47.63 119058* 1856 0.80 549 387 132 93 1214 8.4 119 17.49 12.35 12.93 0.1235 1.382 8.754 24.1 17.0 0.0360 0.0254 0.525 0.726 1.04 4.250 107.95 4.85 2.20 1.875 47.63 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES * Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers. * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales. 10 3.55M99 3.55" (90mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK RTMD products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 11 3.55M99 3.9" (99mm) Diameter, 4 Pole, Brushless DC Motor This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron. Motor Data Voltage Input No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power Torque Constant Voltage Constant Length ("L" above) Weight Shaft Diameter ("D" above) Shaft Length ("S" above) Unit of Measure Volts DC RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts oz.-in. /amp Ncm/amp V/kRPM V/rad/sec inches mm lb. kg inches mm inches mm Drive Electronics Part Numbers 071033 12 6700 1 72 51 28 20 4500 14 94 2.42 1.71 1.79 0.0171 5.33 135.38 6.4 2.9 .2495 6.337 .83 21.08 Internal 071070 13.8 3750 2.5 210 148 60 42 2527 14.3 113 4.98 3.51 3.68 0.0351 6.08 154.43 7.3 3.3 .6250 15.8750 1.00 25.40 Internal 071031 74 3700 0.22 334 236 85 60 2700 3.2 171 27.04 19.10 20 0.1910 6.68 169.67 8.0 3.6 .312 7.925 1.65 41.91 Internal 071145 27.6 3000 0.5 453 320 100 71 2100 8 155 12.44 8.79 9.20 0.0879 7.68 195.07 9.3 4.2 .4997 12.6924 2.25 57.15 Internal NOTES * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 12 3.9M99 3.9" (99mm) Diameter, 4 Pole, Brushless DC Motor This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 13 3.9M99 5.25" (133mm) Diameter, 4 Pole, Brushless DC Motor This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron. Motor Data Voltage Input No Load Speed, Nominal No Load Current, Nominal Stall Torque, Theoretical Continuous Torque Speed @ Torque, Nominal Current @ Torque, Nominal Continuous Power Torque Constant Voltage Constant Length ("L" above) Weight Shaft Diameter ("D" above) Shaft Length ("S" above) Drive Electronics Drive Electronics Part Number Unit of Measure Volts DC RPM amps oz.-in. Ncm oz.-in. Ncm RPM amps watts oz.-in. /amp Ncm/amp V/kRPM V/rad/sec inches mm lb. kg inches mm inches mm Internal or External Part Numbers 528512 27.6 4055 1.6 2403 1697 192 136 3250 23 467 9.20 6.21 6.81 0.0621 6.76 171.70 18 8.2 .3747 9.5174 1.00 25.40 Internal 071087 27 1935 0.8 4380 3094 368 260 1573 20 433 18.85 13.31 13.94 0.1331 7.86 199.64 20 9.1 .6250 15.8750 2.06 52.32 Internal 071190 27 1765 0.7 6400 4519 560 395 1445 27.5 605 20.68 14.61 15.30 0.1461 10.36 263.14 23 10.4 .7497 19.0424 3.25 82.55 Internal 524647 74 2565 0.62 18000 12707 720 508 2253 18.5 1214 39.01 27.55 28.85 0.2755 8.91 226.31 24 10.9 .7497 19.0424 7.09 180.09 External *524506 27 2000 2.5 15383 10862 832 587 1750 46.0 1090 18.25 12.89 13.50 0.1289 10.09 256.29 27 12.2 .6250 15.8750 2.05/2.05 52.07/52.07 External N/A N/A N/A 524731 524508 *Part Number 524506 has a dual shaft. NOTES * Motor design characteristics are based on an operating environment of 25C. * Nominal and maximum performance figures are based on a winding temperature of 105C. * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK RTMD products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales. 14 5.25M99 5.25" (133mm) Diameter, 4 Pole, Brushless DC Motor External Drive Part Number 524731 524508 This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 15 5.25M99 2.9" (74mm) BLDC Low-Voltage Blower Blower Data Voltage Input Unit of Measure 119495 Part Number 119496 VDC 12 24 Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Air Flow 12/24 VDC 1 1 in. H2O, Sealed 3.4 3.4 mBar 8.4 8.4 CFM 22 22 L/sec 10.4 10.4 Typical Performance Points Pressure 0 CFM in. H2O 3.4 3.4 4 CFM in. H2O 3.1 3.1 8 CFM in. H2O 2.9 2.9 12 CFM in. H2O 2.5 2.5 16 CFM in. H2O 1.8 1.8 Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 16 2.9BLV99 2.9" (74mm) BLDC Low-Voltage Blower 12/24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 17 2.9BLV99 3.0" (76mm) BLDC Low-Voltage Blower Blower Data Voltage Input Unit of Measure 119349* Part Number 119350* VDC 12 24 Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Air Flow 12/24 VDC 1 1 in. H2O, Sealed 10 10 mBar 24.9 24.9 CFM 18 18 L/sec 8.5 8.5 Typical Performance Points Pressure 0 CFM in. H2O 10 10 4 CFM in. H2O 9.1 9.1 8 CFM in. H2O 7.6 7.6 12 CFM in. H2O 5.4 5.4 16 CFM in. H2O 2.4 2.4 18 CFM in. H2O 0 0 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 18 3BLV99 3.0" (76mm) BLDC Low-Voltage Blower 12/24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 19 3BLV99 3.3" (84mm) BLDC Low-Voltage Blower Blower Data Voltage Input Unit of Measure 119497 Part Number 119498 VDC 12 24 Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Air Flow 12/24 VDC 1 1 in. H2O, Sealed 27.3 27.3 mBar 67.9 67.9 CFM 7.5 7.5 L/sec 3.5 3.5 Typical Performance Points Pressure 0 CFM in. H2O 27.0 27.0 2 CFM in. H2O 26.0 26.0 4 CFM in. H2O 20.5 20.5 6 CFM in. H2O 9.0 9.0 8 CFM in. H2O 0 0 Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 20 3.3BLV99 3.3" (84mm) BLDC Low-Voltage Blower 12/24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 21 3.3BLV99 4.5" (114mm) BLDC Low-Voltage Blower Blower Data Voltage Input Unit of Measure 119494 Part Number 119395 VDC 12 24 Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Air Flow 12/24 VDC 1 1 in. H2O, Sealed 28.4 28.4 mBar 70.7 70.7 CFM 9.1 9.1 L/sec 4.3 4.3 Typical Performance Points Pressure 0 CFM in. H2O 28.4 28.4 2 CFM in. H2O 26.2 26.2 4 CFM in. H2O 22.4 22.4 6 CFM in. H2O 15.3 15.3 8 CFM in. H2O 5.6 5.6 10 CFM in. H2O 0 0 Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Speed is controlled by input voltage. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 22 4.5BLV99 4.5" (114mm) BLDC Low-Voltage Blower 12/24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 23 4.5BLV99 5.0" (127mm) BLDC Low-Voltage Blower Blower Data Voltage Input Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Drive Electronics 12/24 VDC Part Number Standard Flow Unit Measure 119380 119381 M 119382 E VDC 12 in. H2O 1 12 mBar CFM L/sec Internal or External High Output 119383 119384 M 119385 E 119375 119378 M 119379 E 12 24 24 24 24 1 12 1 12 1 12 1 24 1 24 30 34 30 34 30 34 30 34 60 45 60 45 16 External 16 Internal 16 External 16 Internal 21 External 21 Internal Typical Performance Points Pressure Air Flow 0 CFM 10 CFM in. H2O in. H2O 12.5 11.7 12.5 11.7 12.5 11.7 12.5 11.7 24.3 22.0 24.3 22.0 20 CFM 30 CFM in. H2O in. H2O 7.6 2.3 7.6 2.3 7.6 2.3 7.6 2.3 18.4 10.8 18.4 10.8 40 CFM in. H2O 3.5 3.5 NOTES: Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max. Speed Control: Internal - E (Electrical): Pulse Width Modulated or Analog input voltage (User Supplied), 0 to 5 Volts DC Nominal M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. External - These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and speed control. AMETEK blower controller part numbers 48069 for 12VDC blowers and 48070 for 24 VDC blowers are design for use with the above blowers. 24 5BLV99 5.0" (127mm) BLDC Low-Voltage Blower 12/24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 25 5BLV99 5.1" (130mm) BLDC Low-Voltage Blower Blower Data Voltage Input Unit of Measure 119396 Part Number 119397 VDC 12 24 Stages Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Air Flow 12/24 VDC in. H2O, Sealed 1 1 25.70 25.70 mBar 64 64 CFM 15.30 15.30 L/sec 7.22 7.22 Typical Performance Points Pressure 0 CFM in. H2O 25.7 25.7 2 CFM in. H2O 23.8 23.8 4 CFM in. H2O 21.7 21.7 6 CFM in. H2O 19.5 19.5 8 CFM in. H2O 16.5 16.5 10 CFM in. H2O 12.0 12.0 12 CFM in. H2O 7.1 7.1 14 CFM in. H2O 2.2 2.2 16 CFM in. H2O 0 0 Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection. Input voltages listed in the chart above indicate the controller input voltage requirement. Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max. Speed Control: Via 0.5 VDC analog signal or potentiometer setting at controller. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 26 5.1BLV99 5.1" (130mm) BLDC Low-Voltage Blower 12/24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 27 5.1BLV99 5.7" (145mm) BLDC Low-Voltage Blower Blower Data Voltage Input Stages Vacuum, Max. (Sealed Vacuum) Pressure, Max. (Sealed Pressure) Flow Rate, Max. (Open Flow) Length Dimension "L" Unit of Measure 24 VDC Part Numbers in. H2O mBar 116521* 24 1 6 15 116522 24 2 20 50 116450* 24 3 24 60 in. H2O, sealed mBar 8.2 20 22 55 26 64 CFM L/sec inches mm 39 18 2.65 67.31 35 17 3.66 92.96 38 18 4.56 115.82 VDC Typical Performance Points Pressure Air Flow 0 CFM in. H2O 8.2 35.7 26.0 5 CFM in. H2O 8.0 18.1 23.0 10 CFM in. H2O 7.6 15.5 22.0 15 CFM in. H2O 7.2 12.8 20.5 20 CFM in. H2O 6.3 10.0 17.5 25 CFM in. H2O 5.0 6.3 13.0 30 CFM in. H2O 3.3 4.0 8.5 35 CFM in. H2O 1.7 0.10 3.0 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection. Input voltages listed in the chart above indicate the controller input voltage requirement. Input current: 6-10 Amps, Current is dependent on blower model. Temperature: Working Air: 0o C to 45C, Ambient Air: 0o C to 45C, Storage Air: -40o C to 85C Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamp leakage max. Speed Control: Speed control is achieved at the blower controller. Refer to the controller section (PAGE 45) of this catalog for proper controller operation. NOTES: * This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications. * AMETEK Rotron products are not designed for and should not be used in medical life support applications. * AMETEK reserves the right to revise its products without notification. * The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 28 5.7BLV99 5.7" (145mm) BLDC Low-Voltage Blower 24 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 29 5.7BLV99 5.7" (145mm) BLDC Thru Flow Blower 250 WATT, 120 VOLT Part Number Blower Data Unit of Measure Standard Flow High Flow 116626 M 116627 M 116628 M 116644 M 116645 M 116646 M 116629 E* 116630 E* 116631 E 116647 E 116648 E 116649 E 2 50 3 70 1 24 2 34 3 45 Stages Vacuum, Max. (Sealed Vacuum) in. H2O 1 29 Pressure, Max. (Sealed Pressure) mBar in. H2O 72 32 124 52 174 75 60 27 84 37 112 50 mBar CFM 79 67 129 62 186 46 67 117 92 90 124 80 Inlet/Outlet Diameter L/sec inches 32 1.25 29 1.25 22 1.25 55 1.75 42 1.75 38 1.75 Length (Dimension "I" above) mm inches 31.75 0.74 31.75 1.65 31.75 2.5 44.45 0.76 44.45 1.88 44.45 1.75 Length (Dimension "L" above) mm inches 18.80 3.21 41.91 4.12 63.50 5.02 19.30 3.28 47.75 4.33 44.45 5.34 mm 81.53 104.65 127.51 83.31 109.98 135.64 Flow Rate, Max. (Open Flow) Typical Performance Points Air Flow Pressure 0 CFM in. H2O 32.0 52.2 75.0 27.0 37.1 50.0 10 CFM 20 CFM in. H2O in. H2O 30.0 28.1 44.5 42.3 52.2 34.2 26.1 25.3 34.1 31.7 46.3 42.0 30 CFM 40 CFM in. H2O in. H2O 24.3 19.0 31.8 21.8 21.5 8.0 23.3 23.0 28.9 25.9 35.9 28.6 50 CFM 60 CFM in. H2O in. H2O 12.5 6.0 11.7 21.4 18.0 21.4 17.8 21.9 15.6 70 CFM 80 CFM in. H2O in. H2O 16.7 13.9 12.4 5.7 7.5 0 90 CFM 100 CFM in. H2O in. H2O 10.2 6.1 .09 110 CFM in. H2O 2.6 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. 30 5.7/250TFBHV99 5.7" (145mm) BLDC Thru Flow Blower 250 WATT, 120 VOLT Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403. Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 31 5.7/250TFBHV99 5.7" (145mm) BLDC Bypass Blower 250 WATT, 120 VOLT Part Number Blower Data Unit of Measure Standard Flow High Flow 116634 M* 116633 M 116632 M* 116637 M* 116636 M* 116635 M 116640 E* 116639 E 116638 E* 116643 E* 116642 E* 116641 E 2 48 3 65 1 26 2 57.5 3 42 Stages Vacuum, Max. (Sealed Vacuum) in. H2O 1 29 Pressure, Max. (Sealed Pressure) mBar in. H2O 72 32 119 56 161 76 64 27 143 68.0 104 46 mBar CFM 79 68 139 63 188 49 67 115 169 110 114 80 Inlet/Outlet Diameter L/sec inches 32 1.25 30 1.25 23 1.25 54 1.75 52 1.75 38 1.75 Length (Dimension "I" above) mm inches 31.75 0.33 31.75 1.25 31.75 2.14 44.45 0.47 44.45 1.53 44.45 2.53 Length (Dimension "L" above) mm inches 8.38 5.08 31.75 6.35 54.36 6.89 11.94 5.22 38.86 6.27 64.26 7.28 mm 129.03 161.29 175.01 132.59 159.26 184.91 Flow Rate, Max. (Open Flow) Typical Performance Points Air Flow Pressure 0 CFM in. H2O 31.8 56.1 76.2 27.1 48.1 46.0 10 CFM 20 CFM in. H2O in. H2O 28.7 27.7 48.0 44.3 60.3 44.1 25.0 24.4 44.0 41.6 42.8 39.2 30 CFM 40 CFM in. H2O in. H2O 24.7 20.1 38.1 28.9 28.9 16.1 22.9 21.2 37.9 32.2 34.9 30.0 50 CFM 60 CFM in. H2O in. H2O 14.5 7.3 18.2 4.2 19.1 17.2 25.8 20.5 24.3 16.2 70 CFM 80 CFM in. H2O in. H2O 15.0 12.2 15.8 7.1 9.8 90 CFM in. H2O 8.0 100 CFM in. H2O 5.5 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. 32 5.7/250BHV99 5.7" (145mm) BLDC Bypass Blower 250 WATT, 120 VOLT Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #640250-6 (to be supplied by customer), mates with post header assembly. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 33 5.7/250BHV99 5.7" (145mm) BLDC Thru Flow Blower Blower Data 400 WATT, 240 VOLT Part Number Standard Flow Unit of Measure 117629 E* Stages 117630 E* 1 2 Vacuum, Max. (Sealed Vacuum) in. H2O 28 47 mBar 69 117 Pressure, Max. (Sealed Pressure) in. H2O 31 50 mBar 77 124 Flow Rate, Max. (Open Flow) CFM L/sec 67 32 65 31 Length (Dimension "I" above) inches .69 1.60 mm 17.53 40.64 Length (Dimension "L" above) Air Flow inches 3.21 4.12 mm 81.53 104.65 Typical Performance Points Pressure 0 CFM in. H2O 31.1 50.5 10 CFM in. H2O 26.8 45.4 20 CFM in. H2O 23.8 40.9 30 CFM in. H2O 20.5 33.7 40 CFM in. H2O 15.8 25.3 50 CFM in. H2O 10.0 16.0 60 CFM in. H2O 4.4 6.46 70 CFM in. H2O *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 240 Volts AC RMS +/- 10%, 60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. 34 5.7/400TFBHV99 5.7" (145mm) BLDC Thru Flow Blower 400 WATT, 240 VOLT Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 35 5.7/400TFBHV99 5.7" (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT Part Number Blower Data Unit of Measure Stages Standard Flow High Flow 117634 M* 117633 M 117632 M* 117637 M* 117636 M* 117635 M* 117640 E* 117639 E 117638 E* 117643 E* 117642 E* 117641 E* 1 2 3 1 2 3 Vacuum, Max. (Sealed Vacuum) in. H2O mBar 28 69 45 112 60 149 23 57 39 97 53 131 Pressure, Max. (Sealed Pressure) n. H2O mBar 30 74 51 126 70 174 25 62 45 112 61 151 Flow Rate, Max. (Open Flow) CFM L/sec 69 33 62 29 58 27 114 54 97 46 86 41 Inlet/Outlet Diameter inches mm 1.25 31.75 1.25 31.75 1.25 31.75 1.75 44.45 1.75 44.45 1.75 44.45 Length (Dimension "I" above) inches mm 2.53 64.26 1.25 31.75 2.14 54.36 .47 11.94 1.53 38.86 2.53 64.26 Length (Dimension "L" above) inches mm 5.08 129.03 5.99 152.15 6.89 175.01 5.22 132.59 6.27 159.26 7.28 184.91 Typical Performance Points Air Flow Pressure 0 CFM 10 CFM in. H2O in. H2O 30.3 27.9 51.0 44.2 69.9 59.9 24.8 23.6 44.6 41.0 61.5 55.8 20 CFM 30 CFM in. H2O in. H2O 26.2 23.6 41.8 35.9 52.8 44.1 22.6 21.5 39.8 35.8 51.5 46.0 40 CFM 50 CFM in. H2O in. H2O 19.0 13.3 27.8 16.6 32.1 18.1 19.5 17.9 32.0 28.0 40.1 34.2 60 CFM 70 CFM in. H2O in. H2O 7.0 3.7 3.7 16.1 13.8 23.9 17.9 28.2 19.6 80 CFM 90 CFM in. H2O in. H2O 12.0 8.7 12.1 0 8.1 100 CFM 110 CFM in. H2O in. H2O 6.7 0 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. 36 5.7/400BHV99 5.7" (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184. Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp housing #1-480763-0 (to be supplied by customer), mates with post header assembly. *IEC 801 testing has been completed, and specific data can be provided upon request. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 37 5.7/400BHV99 5.7" (145mm) BLDC Bypass Blower Blower Data Unit of Measure 800 WATT, 120 VOLT Part Number High Flow Standard Flow Ultra Flow 117418 M* 119102 M* 119104 M* 117417 E* 119101 E* 119103 E* 119105 E* 1 41 2 71 1 26 Stages Vacuum, Max. (Sealed Vacuum) in. H2O 3 106 Pressure, Max. (Sealed Pressure) mBar in. H2O 263 115 102 44 176 76 64 29 mBar CFM 285 67 109 161 188 119 72 242 Inlet/Outlet Diameter L/sec inches 32 1.25 76 1.75 56 1.75 114 2.75/2.50 Length (Dimension "I" above) mm inches 31.75 2.12 44.45 .47 44.45 1.53 69.85/63.50 .71 Length (Dimension "L" above) mm inches 53.85 6.87 11.94 5.30 38.86 6.35 18.03 5.46 mm 174.50 134.62 161.29 138.68 Flow Rate, Max. (Open Flow) Typical Performance Points Air Flow Pressure 0 CFM in. H2O 115.8 44.1 76.2 29.3 20 CFM 40 CFM in. H2O in. H2O 86.6 54.9 41.8 39.2 68.4 57.2 27.5 26.1 60 CFM 80 CFM in. H2O in. H2O 18.3 34.1 29.0 43.5 33.2 23.5 21.6 100 CFM 120 CFM in. H2O in. H2O 23.3 14.4 19.8 0 17.6 15.8 140 CFM 160 CFM in. H2O in. H2O 7.0 0 180 CFM 200 CFM in. H2O in. H2O 8.2 5.5 220 CFM 240 CFM in. H2O in. H2O 2.8 1.2 14.1 11.2 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz Input current: 10 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. 38 5.7/800BHV99 5.7" (145mm) BLDC Bypass Blower 800 WATT, 120 VOLT Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under Licence No. R9571008; Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350810-1(to be supplied by customer), mates with post header assembly. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 39 5.7/800BHV99 5.7" (145mm) DC Bypass Blower Blower Data Unit of Measure 1200 WATT, 240 VOLT Part Number High Flow Standard Flow Ultra Flow 117416 M* 119152 M* 119154 M* 117415 E* 119151 E* 119153 E* 119155 E* 1 50 2 91 1 33 Stages Vacuum, Max. (Sealed Vacuum) in. H2O 3 135 Pressure, Max. (Sealed Pressure) mBar in. H O 335 144 124 54 226 97 82 39 Flow Rate, Max. (Open Flow) mBar CFM 357 82 134 190 241 156 97 307 Inlet/Outlet Diameter L/sec inches 39 1.25 90 1.75 74 1.75 145 2.75/2.50 Length (Dimension "I" above) mm inches 31.75 2.12 44.45 .47 44.45 1.53 69.85/63.50 .70 Length (Dimension "L" above) mm inches 53.85 6.87 11.94 5.11 38.86 6.35 17.78 5.47 mm 174.50 128.77 161.29 138.94 2 Typical Performance Points Air Flow Pressure 0 CFM 20 CFM in. H2O in. H2O 144.3 129.1 54.0 53.9 97.0 92.5 39.2 38.0 40 CFM 60 CFM in. H2O in. H2O 102.9 60.8 51.1 47.0 85.8 75.9 37.5 35.3 80 CFM 100 CFM in. H2O in. H2O 10.8 43.2 37.0 62.3 40.5 33.5 31.4 120 CFM 140 CFM in. H2O in. H2O 29.4 22.3 32.1 15.0 28.0 25.4 160 CFM 180 CFM in. H2O in. H2O 14.2 200 CFM 220 CFM in. H2O in. H2O 16.1 13.1 240 CFM 260 CFM in. H2O in. H2O 10.0 7.4 280 CFM 300 CFM in. H2O in. H2O 4.3 1.0 21.5 18.5 *These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information. NOTES: Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz Input current: 5 amps AC RMS maximum Temperature: Working Air: 0o C to 50C, Ambient Air: 0o C to 50C, Storage Air: -40o C to 85C Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. 40 5.7/1200BHV99 5.7" (145mm) DC Bypass Blower 1200 WATT, 240 VOLT NOTES (continued): Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly. *IEC 801 testing has been completed, and specific data can be provided upon request. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 41 5.7/1200BHV99 5 Amp BLDC Blower Controller Blower Contollers Controller Data 48132 Max Continuous Current 5A Input Voltage Range 11-52 VDC Controller PWM Frequency 25 kHz Analog Speed Input 0-5 VDC 600 or 1200 Electrical Hall Spacing Waveform 8-Step Trapezoidal Current Limit Protection Yes Rotation CW / CCW NOTES: Temperature: Operating: 0o C to 50C, Storage Air: -40o C to 85C Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by adjusting the potentiometer when J6 is in position 1 to 2. Current Control: Trip point is at 5 Amp maximum. J1-1 Vin J4-1 Motor Phase A J1-2 Vin Return (Gnd) J4-2 Motor Phase C J1-3 Analog Speed In J4-3 Hall - (Gnd) J4-4 Hall 1 J4-5 Hall 2 J4-6 Hall 3 J4-7 Hall + (+12V) Caution should be taken. Misplacement of jumper setting will destroy the control. Jumper Settings: J4-8 Motor Phase B J6 Set to position 1-2 for internal speed adjust. Set to position 2-3 for analog speed input voltage. J3 Disable or enable to determine forward/reverse rotation. J2 Disable for 60 electrical spacing. Enable for 120 electrical spacing. J5 Set position 1-2 for 16-52 VDC Set position 2-3 for 11-16 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 42 5BC99 10 Amp BLDC Blower Controller Blower Contollers Controller Data 48133 Max Continuous Current 10 A Input Voltage Range 11-52 VDC Controller PWM Frequency 25 kHz Analog Speed Input 0-5 VDC 600 or 1200 Electrical Hall Spacing Waveform 8-Step Trapezoidal Current Limit Protection Yes Rotation CW / CCW NOTES: Temperature: Operating: 0o C to 50C, Storage Air: -40o C to 85C Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by adjusting the potentiometer when J6 is in position 1to 2. Current Control: Trip point is at 10 Amp maximum. J1-1 Vin J4-1 Phase C J1-2 Gnd J4-2 Phase B J1-3 Analog Speed In J4-3 Phase A J4-4 Hall - (Gnd) J4-5 Hall + (+12V) J4-6 Hall 1 J4-7 Hall 2 Caution should be taken. Misplacement of jumper setting will destroy the control. Jumper Settings: J4-8 Hall 3 J6 Set to position 1-2 for internal speed adjust. Set to position 2-3 for analog speed input voltage. J3 Disable or enable to determine forward/reverse rotation. J2 Disable for 60 electrical spacing. Enable for 120 electrical spacing. J5 Set position 1-2 for 16-52 VDC Set position 2-3 for 11-16 VDC This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 43 5BC99 20 Amp BLDC Motor Controller Motor Contoller Controller Data 48134 Max Continuous Current 20 A Input Voltage Range 11-52 VDC Controller PWM Frequency 25 kHz Analog Speed Input 0-5 VDC 600 or 1200 Electrical Hall Spacing Waveform 8-Step Trapezoidal Current Limit Protection Yes Rotation CW / CCW NOTES: Temperature: Operating: 0o C to 50C, Storage Air: -40o C to 85C Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is achieved by adjusting the potentiometer when J6 is in position 1 to 2. Current Control: Trip point is at 20 Amp maximum. Caution should be taken. Misplacement of jumper setting will destroy the control. Jumper Settings: J4-6 Brake J4-12 Analog/In J1-1 Vin J4-5 Hall + J4-11 Freq. Out J1-2 Phase A J4-4 Hall 3 J4-10 For./Rev. J1-3 Phase B J4-3 Hall 2 J4-9 Output Enable J1-4 Phase C J4-2 Hall 1 J4-8 Vref J1-5 Ground J4-1 Gnd J4-7 Ground J5 Set to position 1-2 for 16-52 VDC operation. Set to position 2-3 for 11-16 VDC operation. J6 Set to position 1-2 for internal speed adjust. Set to position 2-3 for analog speed input voltage. J3 Disable or enable to determine forward/reverse rotation. J2 Disable for 60 electrical spacing. Enable for 120 electrical spacing. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. 44 20MC99 BLDC Motor/Blower Controller Numbers Motor/Blower Part Numbers Controller Part Numbers Mating Cable From Controller to Blower/Motor Input Power Cable 119272 48134 N/A 119275 48134 119000 48134 119001 48134 119002 Cable mm 39831 457.212.7 inches 18.00.50 N/A 39817 457.2 12.7 18.00.50 N/A N/A 39817-1 609.612.7 24.00.50 39831 or 39817* N/A 39817-2 304.812.7 12.00+.50 39831 or 39817* N/A 39851 152.412.7 6.00.50 48134 39831 or 39817* N/A 39851-1 304.83.0 12.00.12 119003 48134 39831 or 39817* N/A 39851-2 457.23.0 18.00.12 119004 48134 39831 or 39817* N/A 39851-3 609.63.0 24.00.12 119005 48134 39831 or 39817* N/A 39685 145.03.0 5.71.12 119006 48134 39831 or 39817* N/A 39685-1 292.13.0 11.50.12 119007 48134 39831 or 39817* N/A 39685-2 241.33.0 9.50.12 119008 48134 39831 or 39817* N/A 39685-3 304.812.7 12.00.50 119050 48134 39831 or 39817* N/A 39685-4 457.212.7 18.00.50 119051 48134 39831 or 39817* N/A 39685-5 609.612.7 24.00.50 119052 48134 39831 or 39817* N/A 39773 368.312.7 14.50.50 119053 48134 39831 or 39817* N/A 39773-1 304.812.7 12.00.50 119054 48134 39831 or 39817* N/A 39773-2 457.212.7 18.00.50 119055 48134 39831 or 39817* N/A 39773-3 609.612.7 24.00.50 119056 48134 39831 or 39817* N/A 119057 48134 39831 or 39817* N/A 119058 48134 39831 or 39817* N/A 119375 48133 39851 39773 119380 48133 39851 39773 119383 48133 39851 39773 119381 N/A N/A 39773 119382 N/A N/A 39773 119384 N/A N/A 39773 119385 N/A N/A 39773 119378 N/A N/A 39773 119379 N/A N/A 39773 119396 48134 N/A N/A 119397 48134 N/A N/A 116521 48133 N/A 39773 116522 48133 N/A 39773 116450 48133 N/A 39773 117007** 48132 39685 39773 117011** 48132 39685 39773 119319** 48132 39685 39773 119317** 48132 39685 39773 * Cable 39831 transfers hall signals from the motor to the controller. Cable 39817 does the same, but also provides cabling for analog input, tach output, braking, forward/reverse, enable/disable, and voltage reference of a nominal 6.25 VDC at a maximum of 10 mAmp. ** Earlier versions of the 5.0" Minijammer blower. 45 MBCP99 PLEASE COMPLETE THIS FORM AND FAX IT TO (330) 678-8227, ATTENTION: ROTRON MARKETING DEPARTMENT DATE COMPANY ADDRESS CITY STATE ZIP NAME TITLE DEPT. TELEPHONE FAX Complete applicable side for additional information. Blower Sizing Motor Sizing Purpose of product which blower is to be incorporated in Purpose of product which motor is to be incorporated in Describe general operation Describe general operation Estimated annual requirements Estimated annual requirements Power Supply VDC Power Supply VAC VDC Other Air Flow Requirements To CFM Speed Requirements Pressure Requirements To In. H2O Maximum Continuous Performace Requirement Standard Operating Point: Pressure or Vacuum In. H2O, Flow CFM Surrounding Temperature: Min. o F o Max. Speed RPM Torque Oz. In. Power HP To RPM Dimension, Max.: F Diameter Inches, Length Inches Humidity Surrounding Temperature: Agency Requirements: ISO9001 UL TUV CSA Min. Other o F Humidity Expected Life Hours Expected Life Hours Production Delivery Date Production Delivery Date Expected Price Range Expected Price Range If Replacement Current Manufacturer If Replacement Current Manufacturer Model Model 46 Max. o F Throughout our catalog, you will find terminology used for air moving selection and product sizing. Below are a few of the key terms: Flow Specific Gravity * Volume Rate/Time * AMETEK charts are in SCFM, m3/min, or L/S * SCFM = Standard Cubic Feet Per Minute (American) * Air density = 0.075 lb/cubic foot * M3/min = Cubic Meters Per Minute (Metric) * L/sec = Liters Per Second (Metric) * 1 m3/min = 35.3 SCFM * 1 L/sec = 2.119 SCFM * See Standard Engineering Conversions for other flows on pg. 44 * Density Ratio Relative to Air * Standard Air SG = 1.0 * Methane SG = 0.55 Velocity * * * * Distance/Time or Flow/Area FPM = Feet Per Minute (American) M/min = Meters Per Minute (Metric) See Standard Engineering Conversion Chart for other velocities on pg. 44 Pressure Drop/Back Pressure/Impedance Pressure * Friction causes air to slow down and lost energy is measured in pressure drop terms * Typical pressure drop areas include piping, elbows, accessories and system * Each fixed system has a fixed system impedance caused by a single or multiple pressure drop points * Changing the system impedance will cause the blower's work point to change * Force/Area * AMETEK charts are in In. H2O (IWG), PSIG, MM of Water, IHG, or mbar * IWG = Inches of Water Gauge (American) * PSIG = Pounds Per Square Inch Gauge (American) * mm of Water = Millimeter of Water Gauge (Metric) * IHG = Inches of Mercury Gauge (American) * mbar = Millibar Gauge (Metric) * PSIA = Pounds Per Square Inch Absolute (American) * 27.7 IWG = 1 PSIG * 703.58 MM of Water = 1 PSIG * 2.036 IHG = 1 PSIG * 0.069 Bars = 69 mbar = 1 PSIG * Standard Atmosphere = 0 PSIG = 14.7 PSIA * See Basic Fan Laws Chart for correcting pressure due to speed or density changes Density * Weight/Volume * Standard Air = 0.075 lb/cubic foot 47 AE99 Standard Engineering Conversions MULTIPLY Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres Atmospheres BY 76.0 29.92 406.8348 10,333 1.013 x 105 14.70 760 TO OBTAIN Cms. of Mercury Inches of Mercury Inches of Water Kgs./Sq. Meter Pascals Pounds/Sq. Inch Torrs MULTIPLY Kgs./Cubic Meter Kilometers Kilowatts Kilowatts Kilowatts Kilowatts Kilowatt-Hours BY 0.06243 3281 56.92 737.6 1.341 14.34 3415 TO OBTAIN Pounds/Cubic Foot Feet British Thermal Units/Min. Foot-Pounds/Sec. Horsepower Kg.-Calories/Min. British Thermal Units Bars Bars Bars Bars British British British British British 0.9869 1. x 10 5 1.020 x 104 14.50 0.2520 777.5 1054 107.5 2.928 x 10-4 Atmospheres Dynes/Sq. Cm. Kgs./Square Meter Pounds/Sq. Inch Kilogram-Calories Foot-Pounds Joules Kilogram-Meters Kilowatt-Hours Liters Liters Liters Liters Liters/Minute Log 10 N Log N or Ln N 10 3 61.02 10 -3 .2642 .0353 2.303 0.4343 Cubic Centimeters Cubic Inches Cubic Meters Gallons Cubic Feet/Minute Log EN or Ln N Log 10 N Centimeters of Mercury Centimeters of Mercury Centimeters of Mercury Centimeters of Mercury Centimeters/Second Centimeters/Second Cubic Centimeters Cubic Centimeters Cubic Centimeters Cubic Centimeters Cubic Feet Cubic Feet Cubic Feet Cubic Feet Cubic Feet Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Feet/Minute Cubic Inches Cubic Inches Cubic Inches Cubic Meters Cubic Meters Cubic Meters Cubic Meters/Hour Cubic Meters/Minute 0.01316 0.0372 136.0 0.1934 1.969 0.6 3.531 x 10-5 6.102 x 10-2 10-6 10-3 2.832 x 104 1728 0.02832 0.03704 28.32 472.0 1.6992 .02832 28.32 0.4720 62.4 16.39 5.787 x 10-4 1.639 x 10-5 105 35.31 61,023 .5885 35.3107 Atmospheres Inches of Water Kgs./Square Meter Pounds/Sq. Inch Feet/Minute Meters/Minute Cubic Feet Cubic Inches Cubic Meters Liters Cubic Cms. Cubic Inches Cubic Meters Cubic Yards Liters Cubic Cms./Sec. Cubic Meters/Hour Cubic Meters/Minute Liters/Minute Liters/Second Lbs. of Water/Min. Cubic Centimeters Cubic Feet Cubic Meters Cubic Centimeters Cubic Feet Cubic Inches Cubic Feet/Minute Cubic Feet/Minute Meters Meters Meters Meters Meters Miles Miles Miles Millibars Mms. of Mercury Mms. of Mercury Mms. of Mercury 100 3.2808 39.37 10 -3 10 3 5280 1.6093 1760 .4019 0.0394 1.3595-3 0.01934 Centimeters Feet Inches Kilometers Millimeters Feet Kilometers Yards Inches of Water Inches of Mercury Kgs./Square Cm. Pounds/Square Inch Newton Meters .7376 Pound-Force-Foot Ounce - Force - Inch Ounce - Force - Inch Ounce - Force - Inch 0.706 7.06 x 10 -3 5.21 x 10 -3 Newton - Centimeter Newton - Meter Pound - Force - Foot .004 28.87 473,179 16 444,823 453.6 16 14,544 27.68 0.1198 Inches of Water Cubic Inches Cubic Centimeters Ounces (U.S. fluid) Dynes Grams Ounces British Thermal Units (mean) Cubic Inches Gallons Feet Feet Feet Feet Feet of Air (1 atmosphere 60 O F) 30.48 12 0.3048 1/3 Centimeters Inches Meters Yards 5.30 x 10 -4 Pounds/Square Inch Pascals Pints (Liq.) Pints (U.S. liquid) Pints (U.S. liquid) Pounds Pounds Pounds Pounds of Carbon to CO 2 Pounds of Water Pounds of Water Pounds of Water Evaporated at 212 O F Pounds/Cubic Foot Pounds/Cubic Foot Pounds-Force-Foot Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch Pounds/Square Inch 970.3 16.02 4.882 1.3558 0.06804 27.7 2.036 703.1 6.895 x 103 51.715 British Thermal Units Kgs./Cubic Meter Kgs./Square Meter Newton Meters Atmospheres Inches of Water Inches of Mercury Kgs./Square Meter Pascals Millimeters of Mercury at 0 O C Gallons Grams/Cu. Cm. 3.785 62.43 Liters Pounds/Cubic Foot Horsepower Horsepower Horsepower Horsepower Horsepower-Hours 42.44 33,000 10.70 745.7 2547 British Thermal Units/Min. Foot-Pounds/Min. Kg. Calories/Min. Watts British Thermal Units Inches Inches Inches of Mercury Inches of Mercury Inches of Mercury Inches of Mercury Inches of Mercury Inches of Water Inches of Water Inches of Water Inches of Water Inches of Water Inches of Water Inches of Water 2.540 10 3 0.03342 13.60 345.3 25.40 0.4912 0.002458 0.07355 25.40 2.4884 248.8 5.204 0.03613 Centimeters Mils Atmospheres Inches of Water Kgs./Square Meter Mms. of Mercury Pounds/Square In. Atmospheres Inches of Mercury Kgs./Square Meter Millibars Pascals Pounds/Square Ft. Pounds/Square In. Square Centimeters Square Centimeters Square Centimeters Square Feet Square Feet Square Inches Square Inches Square Inches Square Inches Square Inches Square Kilometers Square Kilometers Square Meters Square Meters 1.973 x 105 1.076 x 10-3 0.1550 929.0 0.09290 1.273 x 106 6.452 6.944 x 10-3 106 645.2 10.76 x 106 1.196 x 106 10.764 1.196 Circular Mils Square Feet Square Inches Square Centimeters Square Meters Circular Mils Square Centimeters Square Feet Square Mils Square Millimeters Square Feet Square Yards Square Feet Square Yards 1 1.8 1 5/9 Abs. Temp. (O C) Temp. ( OF) Abs. Temp. ( OF) Temp. ( OC) 0.05692 10 7 44.26 1.341 x 10-3 0.01434 3.415 1.341 x 10-3 British Thermal Units/Min. Ergs/Second Foot-Pounds/Min. Horsepower Kg.-Calories/Min. British Thermal Units Horsepower/Hours Thermal Thermal Thermal Thermal Thermal Units Units Units Units Units Temp. Temp. Temp. Temp. ( O C) +273 ( OC) +17.8 ( OF) +460 ( O F) -32 Watts Watts Watts Watts Watts Watts-Hours Watts-Hours 48 AE99 Density Correction Chart 49 AE99 Physical Laws for Blower Applications In the following formulae these symbols are used: "Standard Air"-Air at 68O F (absolute temperature 528O) and 29.92" Hg. (barometric pressure at sea level). The density of such air is 0.075 lbs./cu. ft. and the specific volume is 13.29 cu. ft./lb. The specific gravity is 1.0. P-Pressure in pounds per square inch (PSI) or inches of mercury column (inches Hg) CFM-Volume in cubic feet per minute RPM-Speed in revolutions per minute The outlet pressure of a blower depends on the condition of the air or gas at the inlet. The inlet condition is influenced by: D-Density in pounds per cubic foot (lbs./cu. ft.) H-Height of air or gas column (ft.) a-Specific gravity (the ratio of density of the gas to density of standard air) SG-Specific Gravity (ratio of density of gas to the density of air) b-Altitude (location of blower) c-Temperature of inlet air Basic Fan Laws Chart VARIABLE VOLUME WHEN SPEED CHANGES Varies DIRECT with Speed Ratio CFM2 = CFM1 WHEN DENSITY CHANGES ( RPM2 RPM1 PRESSURE HORSEPOWER Varies with SQUARE of Speed Ratio Varies with CUBE of Speed Ratio ) Does Not Change P2 = P1 ( RPM2 RPM1 ) 2 HP2 = HP1 Varies DIRECT with Density Ratio P2 = P1 ( RPM2 RPM1 ) 3 Varies DIRECT with Density Ratio ( ) D2 HP2 = HP1 D1 ( ) D2 D1 Volume The Volume changes in direct ratio to the speed. V1 = Original Volume (1000 CFM) Example - A blower is operating at 3500 RPM and delivering 1000 CFM. If the speed is reduced to 3000 RPM, what is the new volume? V2 = New Volume RPM1 = Original Speed (3500 RPM) RPM2 = New Speed (3000 RPM) V2 = V1 3000 = 1000 x ( ( RPM ) ) = 1000 x .857 = 857 CFM 3500 RPM 2 1 1 1 Pressure Pressure (barometric) varies in direct proportion to altitude. Let: V1 = Volume of standard air (1000 CFM) Example - A blower is to operate at an elevation of 6000 feet and is to deliver 3 PSI pressure. What pressure (standard air) blower is required? 29.92 Pressure = 3 x = 3.75 or 3 3/4 PSI 23.98 V2 = Volume of thinner air Hg1 = Barometric pressure sea level (29.92) Hg2 = Barometric pressure 6000' (23.98) V2 = V1 x Hg1 = 1000 x 29.92 = 1248 CFM 23.98 Hg2 If it is desired to determine what pressure a 3 PSI (standard air) blower will deliver at 6000 feet - 23.98 Pressure = 3 x = 2.4 or about 2 1/2 PSI 29.92 The pressure changes as the square of the speed ratio. Example - A blower is operating at a speed of 3500 RPM and delivering air at 5.0 PSI pressure. If the speed is reduced to 3000 RPM, what is the new pressure? When a blower is to operate at a high altitude it is frequently specified that the blower be capable of handling a given volume of "standard air". It is then necessary to determine the equivalent volume of air at the higher altitude. P1 = Original Pressure (5 PSI) P2 = New Pressure Example - A blower is to operate 6000 feet altitude and is to handle 1000 CFM of standard air. What is the CFM of air the blower must handle at 6000 feet altitude? RPM1 = Original Speed (3500 RPM) RPM2 = New Speed (3000 RPM) RPM2 2 3000 = 5x P2 = P 1 RPM1 3500 ( 50 ) ( 2 ) = 5 x .735 = 3.68 PSI AE99 The Air Density varies in inverse proportion to the absolute temperature. Pressure varies in direct proportion to the density. Example - A 3 PSI (standard air) blower is to be used to handle gas having a specific gravity of 0.5. What pressure does the blower create when handling the gas? Example - A blower is to handle 200O F air at 3 PSI pressure. What pressure (standard air) blower is required? Let: P1 = Pressure hot air (3 PSI) Let: Pa Pg SG P2 = Pressure standard air AT1 = Absolute temperature hot air (200+460=660O F) Pg = Pa x SG = 3 x .5 = 1.5 PSI AT2 = Absolute temperature standard air (68+460=528O F) P 2 = P1 x AT1 AT 2 =3x 660 528 = Air pressure (3 PSI) = Gas pressure = Specific gravity of gas (0.5) If we are required to handle a gas having a specific gravity of 0.5 at 1.5 PSI pressure, we can determine the standard air pressure blower as follows: = 3.75 or 3 3/4 PSI Let: Pa = Pg = 1.5 = 3 PSI SG .5 A blower is capable of delivering 3 PSI pressure with standard air. What pressure will it develop handling 200O F inlet air? P1 = P2 x AT2 = 3 x 528 = 2.4 or about 2 1/2 PSI 660 AT1 Horsepower The horsepower changes as the cube of the speed ratio. Horsepower vs. Specific Gravity & Ratio of Density. The horsepower varies in direct proportion to the specific gravity (ratio of density of gas to density of air). Example - A blower is operating at a speed of 3500 RPM and requiring 50 horsepower. If the speed is reduced to 3000 RPM, what is the new required horsepower? Example - A standard air blower requires a 10 HP motor. What horsepower is required when this blower is to handle a gas whose specific gravity is 0.5? HP1 = Original Horsepower (50) HP2 = New Horsepower RPM1 = Original Speed (3500 RPM) RPM2 = New Speed (3000 RPM) HP2 = HP1 x ( RPM2 RPM1 3 ) = 50 x ( 3000 3500 HP = 10 x 0.5 = 5 horsepower It is possible that several of the above modifications may be required on one installation. Therefore, it may be necessary to use various combinations of these formulae. 3 ) = 50 x .630 = 31.5 horsepower 51 AE99 AMETEK Global Operations AMETEK Aerospace AMETEK elektromotory s.r.o. SENSORS/MONITORING SYSTEMS * www.ametek.com/aerospace 50 Fordham Road * Wilmington, MA 01887 U.S.A. Tel: 978-988-4101 * Fax: 978-988-4944 ul. Beloveska 318 * Nachod 54701 Czech Republic Tel: 420-441-23877 * Fax: 420-441-23111 Shaded pole induction motors for heating and ventilation, thru-flow and bypass vacuum cleaner motors, and universal series drive motors. Sensors and interconnects for engines, airframes, launch vehicles and satellites, including fuel flow, temperature, speed, pressure and liquid level. Monitoring systems, including vibration. Digital bus adapters. AMETEK GmbH AVIONICS * www.ametek.com/aerospace 900 Clymer Avenue * Sellersville, PA 18960 U.S.A. Tel: 215-257-6531 * Fax: 215-257-1888 Weilimdorfer Str. 47 * D-70825 Korntal-Munchingen Germany Tel: +49-711-838-7876 * Fax: +49-711-838-7862 Sales for Electromechanical Group--Europe. Data acquisition and interface units for avionics systems. Engine indicating systems. RVSM altimeters. Fuel/hydraulic/water quality measuring systems. AMETEK Italia S.r.l. GULTON-STATHAM Products * www.gultonstatham.com 1644 Whittier Avenue * Costa Mesa, CA 92627 U.S.A. Tel: 949-642-2400 * Fax: 949-642-9490 CIARAMELLA * www.ametek.it Via De Barzi * Robecco Sul Naviglio 20087 Italy Tel: +39-02-946931 * Fax: +39-02-94970518 Pressure, proximity and position sensors for aircraft, engines, airborne and land-based launch vehicles, satellites, and industrial applications angle of attack sensors and stall warning computers. Mud density and smart recording transmitters for oil and gas drilling. Universal series drive motors for outdoor power equipment, small household appliances, floor care and personal care products, and special applications. VACUUM Products * www.ametek.it Via De Gasperi 18/A * Ripalta Cremasca 26010 Italy Tel: +39-0373-2101 * Fax: +39-0373-268200 SERVICE OPERATIONS Distribution and Warehousing Operation * www.ametek.com/aerospace Wilmington Service Center * 50 Fordham Road * Wilmington, MA 01887 U.S.A. Tel: Warehouse 978-988-4100, Service: 978-988-4729 Fax: Warehouse: 978-988-4720, Service: 978-988-4408 Thru-flow and bypass vacuum motors for household, commercial, industrial canister, and upright vacuum cleaners. AMETEK Lamb Electric Distribution of aerospace and industrial instruments, sensors, and spare parts. Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No. A8PR-221J. www.ameteklamb.com 627 Lake Street * Kent, OH 44240 U.S.A. Tel: 330-673-3451 * Fax: 330-673-8994 Seattle Support Center * www.ametek.com/aerospace 4560 150th Avenue NE * Redmond, WA 98052 U.S.A. Tel: 425-881-1172 * Fax: 425-881-7292 Motors and motor-blower systems for industrial, commercial, and household vacuum cleaners, ACUSTEK(R) motors, related floor-care equipment, and other applications such as paint sprayers, material transport, spas, and outdoor power equipment, requiring a vacuum, pressure, or drive source. Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No. HU6R600N. AMETEK Chemical Products AMETEK Motors Shanghai Co. Ltd. HAVEG * www.ametek.com/haveg * E-mail: haveg@ametek.com 900 Greenbank Road * Wilmington, DE 19808 U.S.A. Tel: 302-995-0400, 800-441-7777 * Fax: 302-995-0491 #1 AMETEK Road * Jiu Ting Economic Development Zone, Shanghai 201615 China Tel: 86-21-5763-2408 * Fax: 86-21-5763-2411 SILTEMP(R), ULTISIL(R), HAVEGLASTM high-thermal-resistance fabrics for welding blankets, furnace curtains, and insulation. FLEXSIL(R) molten metal filters. Corrosion-resistant HAVEG(R) tanks, towers, valves, and piping. Fluoropolymer tubing and Heat Exchangers of TEFLON*. Fractional horsepower electric motors and blowers for Asian and worldwide markets. AMETEK Power and Industrial Products WESTCHESTER PLASTICS * www.ametek-westchesterplas.com Green Acres Industrial Park * Nesquehoning, PA 18240 U.S.A Tel: 570-645-2191 * Fax: 570-645-8564 www.ametek.com/power * E-mail: power.industrial@ametek.com 50 Fordham Road * Wilmington, MA 01887 U.S.A. Tel: 978-988-4101 * Fax: 978-988-4179 Custom color compounding of elastomers, blends, reactive modifiers and other thermoplastic resins. Small scale pilot runs through commercial production runs. Custom color matching services. Temperature, pressure, speed and flame sensors and interconnects for land, marine, and utility gas turbines and industrial boilers and burners. Gulton-Statham pressure, mud density, and smart recording transmitters for oil and gas drilling. AMETEK Dixson AMETEK Precision Instruments Europe GmbH DIXSON * www.ametekdixson.com 287 27 Road * Grand Junction, CO 81503 U.S.A. Tel: 888-302-0639, 970-242-8863 * Fax: 970-245-6267 Rudolf-Diesel-Strasse 16 * D-40670 Meerbusch Germany Tel: +49-2159-9136-0 * Fax: +49-2159-9136-39 OEM instrumentation and data collection units for the heavy duty vehicular market. Industrial bargraph panel meters for commercial and nuclear applications. Process controls and controllers for the fast-food preparation industry. Sales for Electronic Instruments Group--Europe and for AMETEK Rotron Technical Motor Division--Europe. AMETEK Precision Instruments France SARL NATIONAL CONTROLS CORP. (NCC) * www.nationalcontrols.com 1725 Western Drive * West Chicago, IL 60185 U.S.A. Tel: 630-231-5900, 800-323-2593 * Fax: 630-231-1377 3 Avenue des Coudriers, Z.A. de l'Observatoire * Montigny Le Bretonneux 78180 France Tel: 33 1 30 64 89 70 * Fax: 33 1 30 64 89 79 Time delay relays, temperature monitors and controls, solid state relays and voltage monitors, liquid level controls, and dust collectors/controls for the food industry, refrigeration, HVAC, test chambers, and other industrial applications. Sales for Electronic Instruments Group--France and for AMETEK Rotron Technical Motor Division--France. AMETEK Precision Instruments (UK) Ltd. PANALARM * www. panalarm.com 1725 Western Drive * West Chicago, IL 60185 U.S.A. Tel: 847-675-2500 * Fax: 847-675-3011 www.ametek.co.uk * E-mail: sales@ametek.co.uk 2 Queens Drive, Kings Norton Business Centre * Kings Norton, Birmingham B30 3HH England Tel: 44-121-246-2260 * Fax: 44-121-246-2270 Process monitoring annunciators, control room graphic displays, and high-speed event recorders for petrochemical refineries, electrical generation and distribution, airport and train event monitoring, water and wastewater treatment plants. Sales for Electronic Instruments Group--United Kingdom and Ireland. Sales for Panalarm annunciator products--Europe, Middle East, Africa, Pakistan and India. Sales for Thermox products--United Kingdom and Ireland. AMETEK Corporate Office www.ametek.com Station Square * Paoli, PA 19301 U.S.A. Tel: 610-647-2121, 800-473-1286 * Fax: 610-296-3412 52 AMETEK Process & Analytical Instruments AMETEK Specialty Metal Products PROCESS INSTRUMENTS * www.ametekpi.com 455 Corporate Blvd. * Newark, DE 19702 U.S.A. Tel: 302-456-4400, 800-222-6789 * Fax: 302-456-4444 METAL STRIP and SPECIALTY WIRE * www.ametekmetals.com 21 Toelles Road * Wallingford, CT 06492 U.S.A. Tel: 203-265-6731, 800-233-2266 * Fax: 203-265-6407 Continuous on-line photometric and trace moisture analyzers used for advanced process control, emissions monitoring, and product quality improvement. Markets include chemical manufacturing, semiconductor, and special packaging. Wrought powder metallurgy for engineered custom metal strip and wire including SEALVAR(R) iron-nickel cobalt, custom shaped wire, metal matrix composites including HIVOLTM silicon carbide aluminum, and fully dense components (FDC). FDC include vacuum sputtering targets for thin film deposits through the ISOFORMTM technology using the Pneumatic Isostatic Forging process. Product applications include satellites, land-and sea-based radar systems, computers, chip mounting, heat sinks, and reflective coatings. THERMOX Business Unit * www.thermox.com 150 Freeport Road * Pittsburgh, PA 15238 U.S.A. Tel: 412-828-9040 * Fax: 412-826-0399 THERMOX(R) oxygen analyzers for flue gas and industrial gas applications, combustion analyzers for measuring oxygen and combustibles in a single analyzer, CO monitors, and premix gas analyzers. AMETEK Shanghai (SPL) WESTERN RESEARCH * www.ametekpi.com 8 Manning Close N.E. * Calgary, Alberta T2E7N5 Canada Tel: 403-235-8400 * Fax: 403-248-3550 Representative Office of AMETEK Singapore Pte. Ltd. Room 16B5, Harvest Bldg. * #585 Long Hua Xi Road, Shanghai 200232 China Tel: 86-21-6428-4067, 86-21-6469-8814 * Fax: 86-21-6487-5329 AMETEK Singapore Pte. Ltd. Sulfur Recovery Unit process monitoring, control, and emissions analyzers to measure air demand, SO2, H2S, NOx concentrations. Dewpoint monitors, tunable diode laser spectrometers, and temperature monitors. 10 Ang Mo Kio Street 65 * #05-12 TECHPOINT 569059 Singapore Tel: 65-484-2388 * Fax: 65-481-6588 * E-mail: aspl@ametek.com.sg Sales for all AMETEK products--Pacific Rim. AMETEK Rotron AMETEK Test and Calibration Instruments COMMERCIAL BRUSHLESS Products * www.ametektmd.com 627 Lake Street * Kent, OH 44240 U.S.A. Tel: 330-673-3452 * Fax: 330-678-8227 CHATILLON(R) Force Measurement Products * www.chatillon.com 8600 Somerset Drive * Largo, FL 33773 U.S.A. Tel: 727-536-7831, 800-527-9999 * Fax: 727-539-6882 Brushless DC motors, WINDJAMMER(R) and MINIJAMMER(R) motor-blowers, and low-voltage controllers for computers, business machines, medical devices, pumps and compressors, industrial equipment, and such mass-transit vehicles as transit buses, rail cars, and locomotives. Force gauges, universal testing machines, and material test instruments, automated testing software, gripping fixtures and accessories. AMETEK Denmark A/S * www.ametek.com/tci Gydevang 32-34, PO Box 30 * DK-3450 Allerod Denmark Tel: 45-4816-8000 * Fax: 45-4816-8080 MIL-AERO Products * www.rotron.com 9 Hasbrouck Lane * Woodstock, NY 12498 U.S.A. Tel: 914-679-2401 * Fax: 914-679-7080 JOFRA temperature and pressure calibrators and FRODE PEDERSEN sensors (also markets other AMETEK instrument products throughout Europe). AC and brushless DC fans and blowers, heat exchanger and blower systems, fault detection devices, and electronic power conversion devices for the military and aerospace markets. Repair of products manufactured by AMETEK Rotron Technical Motor Division. FAA Repair Station No. AN1R014K. LLOYD INSTRUMENTSTM Material Testing Products www.lloyd-instruments.co.uk 12 Barnes Wallis Road, Segensworth East * Fareham, Hampshire PO15 5TT England Tel: 44-1489-574221 * Fax: 44-1489-885118 INDUSTRIAL Products and BIOFILTRATION Products * www.rotron.com 75 North Street * Saugerties, NY 12477 U.S.A. Tel: 914-246-3401 * Fax: 914-246-3802 Materials testing machines, force gauges and test stands, melt flow indexers, friction testers, melt viscometer, density column, plastic film impact testers, and heat distortion equipment (HDT/VICAT). Industrial Products: Regenerative air blowers for pressure and vacuum applications up to 1800 SCFM and 10 PSIG servicing the Industrial, Environmental, Instrumentation, & Telecommunication markets. Typical applications include solution agitation & aeration, pneumatic conveying, part hold-down and pick up, part blow off, gas & fume extraction, and process gas handling. BiofiltrationProducts: Patented modular Biofiltration systems that remove noxious odors and vapors from gaseous exhaust and air supply systems in commercial, municipal wastewater, and industrial applications. MANSFIELD & GREEN Products * www.ametek.com/tci 8600 Somerset Drive * Largo, FL 33773 U.S.A. Tel: 727-536-7831, 800-527-9999 * Fax: 727-539-6882 Electronic tachometers and stroboscopes, force and torque gauges, deadweight testers, pressure calibrators, diaphragm seals, and air/noise monitoring instruments. AMETEK U.S. Gauge AMETEK Sensor Technology U.S. GAUGE Products * www.ametekusg.com 900 Clymer Ave. * Sellersville, PA 18960 U.S.A. Tel: 215-257-6531 * Fax: 215-257-3058 PATRIOT Products * www.patriotsensors.com 1080 N. Crooks Road * Clawson, MI 48017-1097 U.S.A. Tel: 248-435-0700 * Fax: 248-435-8120 Pressure and temperature gauges for industrial use, process industries, and OEM applications. Pressure gauges for compressed gas, welding, and medical applications. Solid front pressure gauges and diaphragm seals for chemical, petrochemical, and other process industries. Hunter Spring NEG'ATOR(R) and SPIR'ATOR(R) constant force springs and spring powered retracting reels. Position sensors including rotary cam limit switches, programmable limit switches, linear position sensors and rotary encoders; programmable controller bus cards including ultra-high speed programmable limit switches and electronic encoders for linear and rotary inputs; stamping press automation including shut height monitors; specialty products including cable and hose carrier systems. Point level sensor products including conductivity sensors, conductivity relays and magnetic probes; continuous level sensors including magnetostrictive probes for tank gauging and leak monitoring. PMT Products * www.ametekusg.com 820 Pennsylvania Blvd. * Feasterville, PA 19053 U.S.A. Tel: 215-355-6900, 888-625-5895 * Fax: 215-355-2937 Pressure transducers and transmitters for industrial markets, pressure gauges, switches, transmitters, displays and cylinder sales for UHP semiconductor manufacturing markets, level measurement systems, pneumatic controllers, and gas energy content (BTU) meters. DREXELBROOK Products * www.drexelbrook.com 205 Kieth Valley Road * Horsham, PA 19044 U.S.A. Tel: 215 674-1234* Fax: 215 674-2731 RF and ultrasonic level sensors in a broad range of packages for chemical, petrochemical, water, waste water, food, beverage and pharmaceutical monitoring; continuous and point level sensors; IS and EX applications; line powered, low voltage, 4-20mA loop powered, HART and other networked outputs. Clarifier and sludge blanket sensor systems for wastewater applications. Level sensors for aerospace applications. AMEKAI Taiwan Co., Ltd. 2-Floor, No. 214 Alley 1 * Lane 138, Chang-An Street * Pan-Chiao, Taipei Taiwan Tel: 886-2-2954-1765 * Fax: 886-2-2951-3443 Joint venture with Taiwanese partner. General industrial use mechanical pressure gauges for Asian and worldwide markets. AMETEK Specialty Metal Products AMEKAI Meters (XIAMEN) Co., Ltd. CLAD METALS and METAL POWDERS * www.ametekmetals.com Route 519 * Eighty Four, PA 15330 U.S.A. Tel: 724-225-8400 * Fax: 724-225-6622 1-2 Floors, Chuang Xin Bldg., Torch High Technology Industrial Zone Innovate City, Xiamen, Fujian 361006 China Tel: 86-592-603-0565 * Fax: 86-592-603-0570 Stainless steel and nickel clad alloys used in high-quality cookware, sterilizers and chemical processing equipment. Stainless steel, cobalt, and nickel alloy metal powders for powder metallurgy, hardfacing, metal injection molding, polymer filtration, and plastic compounding. Joint venture with Chinese partner. General industrial use mechanical pressure gauges for Asian and worldwide markets. 53 Contact Information ROTRON Technical Products 627 Lake Street Kent, OH 44240 Main Tel: (330) 673-3452 Fax: (330) 678-8227 www.ametektmd.com e-mail: info@ametektmd.com AMETEK GmbH Weilimorder Str. 47 70825 Korntal-Munchingen Germany Main Tel: 49-711-838-7876 Fax: 49-711-838-7862 Distributors Allied Electronics 1-800-433-5700 www.allied.avnet.com Grainger 1-800-323-0620 www.grainger.com 54 AMETEK, Inc. AMETEK is a leading global manufacturer of electrical and electromechanical products for niche markets. Listed on the New York Stock Exchange (AME) since 1930, AMETEK's annual sales are approaching $1 billion. Operations are in North America, Europe, and Asia, with about one-third of sales to markets outside the United States. AMETEK is serving its customers with investments in new products, global and market expansion, strategic acquisitions, and operational excellence. The Company's operating groups are Electronic Instruments and Electromechanical. Rotron The Electromechanical Group (EMG) is one of the world's largest producers of high-speed electric motor products for original equipment manufacturers (OEMs). In business since 1915, EMG is using its core competencies to enhance its worldwide presence. A business unit of AMETEK EMG, Rotron has facilities in California, New York, North Carolina, and Ohio. Rotron serves the military, aerospace, medical, transportation, office equipment, industrial, and environmental markets worldwide. Rotron supports its customers with more than 650 employees that are organized in three business segments: * Technical Products * Military & Aerospace Products * Industrial Products Technical Products Rotron's standard product lines of brushless DC motors, blowers, and controllers offer a wide range of application demands. Brushless DC motors and blowers are an ideal choice for such varied applications as medical instruments, robotics, pumps, compressors, office equipment, fans, machine tools, tape drives, or any other precise rotary motion/air delivery applications. If there is a need for a product with unique performance, mounting environment, or agency requirements, Rotron can supply the solution. ROTRON Technical Products 627 Lake Street, Kent, Ohio 44240 Telephone: 330-673-3452 * Fax: 330-678-8227 * www.ametektmd.com (c)2000, by AMETEK, Inc. 5M200N (140044)