WE’RE BIG ON BRUSHLESSTM
BRUSHLESS DC MOTORS • BLOWERS • CONTROLLERS
ROTRON
Technical Products
○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○ ○○○○○○
Introduction ............................................... 1, 2, 3
BLDC Motors
1.7” (43mm) diameter ........................................... 4, 5
2.5” (64mm) diameter ........................................... 6, 7
3.0” (79mm) diameter ........................................... 8, 9
3.55” (90mm) diameter ....................................... 10, 11
3.9” (99mm) diameter ....................................... 12, 13
5.25” (133mm) diameter ..................................... 14, 15
Low Voltage Blowers (BLDC)
2.9” (74mm) ...................................................... 16, 17
3.0” (76mm)....................................................... 18, 19
3.3” (84mm)....................................................... 20, 21
4.5” (114mm)..................................................... 22, 23
5.0” (127mm) MINIJAMMER ............................. 24, 25
5.1” (130mm)..................................................... 26, 27
5.7” (145mm) WINDJAMMER ........................... 28, 29
High Voltage Blowers (BLDC)
WINDJAMMER
5.7” (145mm) Thru Flow/250 Watt/120VAC ..... 30, 31
5.7” (145mm) Bypass/250 Watt/120VAC .......... 32, 33
5.7” (145mm) Thru Flow//400 Watt/240 VAC ... 34, 35
5.7” (145mm) Bypass/400 Watt/240VAC .......... 36, 37
5.7” (145mm) Bypass/800 Watt/120VAC .......... 38, 39
5.7” (145mm) Bypass/1200 Watt/240VAC ........ 40, 41
Controllers (BLDC)
5 Amp Motor/Blower .......................................... 42
10 Amp Motor/Blower .......................................... 43
20 Amp Motor ...................................................... 44
BLDC Motor/Blower
Controller Part Numbers ................................ 45
Blower/Motor Sizing Sheet ............................ 46
Application Engineering
Basics .................................................47, 48, 49, 50, 51
AMETEK Global Locations ........................ 52, 53
Contact Information ....................................... 54
Table of Contents
®
®
®
1
The AMETEK Electromechanical Group (EMG). . .
is one of the world’s largest producers of high-speed electric motor products for original equipment
manufacturers (OEMs). In business since 1915, EMG uses its core competencies in motion and air
movement products as engineered solutions for application-specific needs. A unit of AMETEK EMG,
Rotron offers Brushless DC motor-, blower-, and controller-based solutions.
The standard product lines of Rotron Technical Products cover a wide range of application demands.
If there is a need for a product with unique performance, mounting, environment or agency require-
ments, Rotron can supply the solution. Whether a customer needs a standard or special design,
Rotron has the solution for your application. AMETEK offers economies of scale that only can be
accomplished by a company that produces more than 23 million motor products per year. With
multiplant capability and flexibility, Rotron is positioned to support our customers’ global programs.
AMETEK Brushless DC Motors and Blowers are an ideal choice for such varied applications as medi-
cal instruments, robotics, pumps, compressors, business equipment, fans, machine tools, tape
drives, or any other precise rotary motion/air delivery applications.
INTRO99
2
Brushless DC Motors. . .
offer precise control for a wide range of applications. Rotron standard motor designs offer
maximum controllable performance, coupled with the reliability of brushless technology in a com-
pact cost effective package. First introduced in 1988, the AMETEK brushless DC motor product line
has continually expanded into one of the largest mixes of fractional horsepower motor products in
the industry.
Motor Selection. . .
is made easy with the wide variety of standard products available from AMETEK. Six different motor
families are available in standard configurations. These include 1.7” (43mm), 2.5” (64mm), 3.0”
(76mm), 3.55” (90mm), 3.9” (99mm), and 5.25” (133mm) diameter motors, with constant torque which
range from 5.75 oz. in. (4.06 Ncm) to 832 oz. in. (5.87 Nm) and horsepower ratings of .014 to 1.75.
Voltage options range from 12VDC to 74VDC. The table below provides a summary of the motor
products, operating voltages, speed and torque ranges sorted by motor diameter. Use this chart to
compare the AMETEK products to the application needs. Detailed motor information is provided on
the individual product sheets.
BLDC MOTORS
Motor Diameter Operating Voltage (DC) Speed Range (RPM) Torque Range (oz. in.)
Controller Input at Nom. Continuous Tor que Maximum Continuous
1.7” (43mm) 12, 24, 36 0 - 3,000 5.75 - 11
2.5” (64mm) 12, 24, 36 0 - 5,000 14 - 69
3.0” (76mm) 13.8, 24, 27.6 0 - 4,930 19.7 - 55
3.55” (90mm) 12, 24, 36 0 - 4,300 22 - 132
3.9” (99mm) 12. 13.8, 27.6, 74 0 - 4,500 28 - 100
5.25” (133mm) 27, 27.6, 74 0 - 4,055 192 - 832
Motor Controllers
All of the AMETEK BLDC Motors require a controller to operate. The controllers require a DC
input which is processed into phase drive signals. The 1.7” (43mm) and 3.0” (76mm) motors
are available with integrated controllers. All other motors require an external controller. Con-
troller details and compatibility to the different motor products are supplied in the controller
section of the catalog.
INTRO99
3
Brushless DC Blowers. . .
offer variable (speed) output for a wide range of vacuum or pressure applications. Standard blower
designs offer brushless DC motor drives coupled to high efficiency fan systems in a compact, cost
effective package. Standard models are available in a wide range of input voltages, including 12, 24,
28, and 36VDC. A complete product line of brushless DC blowers that accepts line voltage input
(120VAC and 240VAC) also is available. AMETEK brushless DC blowers are not designed for, and
should not be used in, life sustaining applications. AMETEK brushless DC blowers are not 100%
sealed and therefore should not be used with flammable or hazardous gases.
Blower Selection. . .
offers a wide variety of standard products available from AMETEK. Thirteen different blower families
are available in standard configurations. These include seven low voltage and six high voltage
products. The low voltage products provide outputs which range from 0 to 28” H20 (pressure) at
flows of 0 to 45 CFM. The high voltage products provide outputs which range from 0 to 162” H20
(pressure) at flows of 0 to 275 CFM.
LOW VOLTAGE PRODUCTS
Blower Diameter Operating Voltage (DC) CFM Range In. H20 (Pressure) In. H20 (Vacuum)
2.9” (74mm) 12, 24 0-22 0-3 -
3” (76mm) 12, 24 0-18 0-10 -
3.3” (84mm) 12, 24 0-7 0-27 -
4.5” (114mm) 12, 24 0-9 0-28 -
5” (127mm) 12, 24 0-45 0-24 -
5.1” (130mm) 12, 24 0-15 0-25 -
5.7” (145mm) 12, 24, 36 0-39 0-28 0-28
HIGH VOLTAGE BYP ASS PRODUCTS
Blower Diameter Operating Voltage (AC) CFM Range In. H20 (Pressure) In. H20 (Vacuum)
5.7” (145mm) 120 (250 Watt) 0-115 0-76 0-65
5.7” (145mm) 120 (800 Watt) 0-242 0-115 0-106
5.7” (145mm) 240 (400 Watt) 0-115 0-144 0-135
5.7” (145mm) 240 (1200 Watt) 0-275 0-162 0-118
HIGH VOLTAGE THRU-FLOW PRODUCTS
Blower Diameter Operating Voltage (AC) CFM Range In. H20 (Pressure) In. H20 (Vacuum)
5.7” (145mm) 120 (250 Watt) 0-117 0-75 0-70
5.7” (145mm) 240 (400 Watt) 0-67 0-50 0-47
INTRO99
4
Motor Data Unit of Part Numbers
Measure 119272* 119275*
No Load Speed, Nominal RP M 4388 4308
No Load Current, Nominal amps .16 .18
Stall Torque, Theoretical oz.-in. 12.7 51.3
Ncm 8.96 36.20
Continuous Torque oz.-in. 5.75 11
Ncm 4.06 7.77
Speed @ To rque, Nominal RP M 2425 3000
Current @ Torque, Nominal amps 1.0 1.75
Continuous Power, Max. watts out 1 0 2 4
Torque Constant oz.-in. /amp 7.39 7.53
Ncm/amp 5.21 5.31
Voltage Constant V/kRPM 5.47 5.57
V/rad/sec 0.052 0.053
Electrical Time Constant millisecond .273 .339
Mechanical Time Constant millisecond .202 .134
Motor Constant oz.-in./(watt^.5) 2.37 4.12
Ncm/(watt^.5) 1.67 2.91
Rotor Inertia oz.-in.sec28.00 x 10-6 1.60 x 10-5
Ncm-sec^2 0.0565 0.0113
Terminal Resistance ohms 9.74 3.34
Terminal Inductance millihenry 2.66 1.13
Thermal Resistance ºC/W 3.5 1.90
Length (“L” above) inches 1.864 2.614
mm 47.35 66.40
Weight lb. .51 .78
kg 0.23 0.35
Shaft Length (“S” above) inches .75 1.00
mm 19.05 25.40
1.7” (43mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC
NOTES
* Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers.
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
1.7M99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
5
1.7” (43mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will
vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support
applications. AMETEK reserves the right to revise its products without notification.
1.7M99
6
Motor Data Unit of Part Numbers
Measure 119000* 119001 119002 119003* 119004 119005 119006 119007 119008*
No Load Speed, Nominal RP M 5947 5389 4233 5468 4636 4019 3575 3191 2879
No Load Current, Nominal amps 1.14 1.07 0.93 1.08 0.98 0.91 0.85 0.81 0.77
Stall Tor que, Theoretical oz.-in. 14 2 17 9 1 91 26 7 2 82 2 94 3 02 31 1 3 19
Ncm 100 127 135 189 199 208 213 219 225
Continuous Torque oz.-in. 14 21 27 34 41 48 55 62 69
Ncm 10 15 19 24 29 34 39 44 49
Speed @ T o rque, Nominal RP M 4928 4234 3286 4228 3455 3074 2645 2290 2002
Current @ Torque, Nominal amps 3.7 4.6 4.5 6.8 6.8 6.8 6.9 6.9 6.9
Continuous Power , Max. watts out 5 1 6 6 6 6 10 6 1 05 109 1 08 10 5 1 02
Torque Constant oz.-in. /amp 5.46 6.02 7.67 5.94 7.00 8.08 9.08 10.17 11.27
Ncm/amp 3.85 4.25 5.42 4.19 4.94 5.70 6.41 7.18 7.96
Voltage Constant V/kRPM 4.04 4.45 5.67 4.39 5.18 5.97 6.71 7.52 8.34
V/rad/sec 0.0385 0.0425 0.0542 0.0419 0.0494 0.0570 0.0641 0.0718 0.0796
Electrical Time Constant millisecond 0.838 0.886 0.937 0.904 0.938 0.965 0.986 1.004 1.019
Mechanical Time Constant millisecond 5.236 4.129 4.080 3.775 4.006 3.668 3.217 3.258 3.021
Motor Constant oz.-in./(watt^.5) 6.8 8.1 9.3 10.1 11.1 12.1 12.9 13.8 14.7
Ncm/(watt^.5) 4.8 5.7 6.6 7.1 7.9 8.6 9.1 9.8 10.4
Rotor Inertia oz.-in.sec20.0017 0.0019 0.0025 0.0027 0.0035 0.0038 0.0038 0.0044 0.0046
Ncm-sec^2 0.0012 0.0013 0.0018 0.0019 0.0025 0.0027 0.0027 0.0031 0.0032
Terminal Resistance ohms 0.648 0.557 0.678 0.348 0.396 0.444 0.493 0.541 0.589
Terminal Inductance millihenry 0.543 0.493 0.635 0.314 0.372 0.429 0.486 0.543 0.601
Thermal Resistance ºC/W 1.26 1.22 1.19 1.15 1.11 1.08 1.04 1.00 0.96
Length (“L” above) inches 2.335 2.335 2.835 2.835 3.585 3.585 3.585 4.085 4.085
mm 59.31 59.31 72.01 72.01 91.06 91.06 91.06 103.76 103.76
Weight lb. 1.15 1.25 1.60 1.75 2.15 2.25 2.30 2.70 2.80
kg 0.52 0.57 0.73 0.79 0.98 1.02 1.04 1.22 1.27
Shaft Length (“S” above) inches .750 .750 .750 .750 1.500 1.500 1.500 1.875 1.875
mm 19.05 19.05 19.05 19.05 38.1 38.1 38.1 47.63 47.63
2.5” (64mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC
NOTES
* Motors require brushless motor controller for operation, refer to the controller section ( page 45) for applicable controllers.
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
2.5M99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
7
2.5” (64mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will
vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support
applications. AMETEK reserves the right to revise its products without notification.
2.5M99
8
Motor Data Unit of Part Numbers
Measure 150004 *150007 E-11488
Voltage Input Volts DC 13.8 27.6 24.0
No Load Speed, Nominal RP M 3770 5510 5400
No Load Current, Nominal amps 0.75 1 1.5
Stall Tor que, Theoretical oz.-in. 169 1300 1298
Ncm 119 915 917
Continuous T orque oz.-in. 19.7 43 55
Ncm 13.9 30 39
Speed @ T o rque, Nominal RP M 2927 4930 4400
Current @ Torque, Nominal amps 4.6 6.9 9.9
Continuous Power watts 43 157 181
Torque Constant oz.-in. /amp 4.90 7.43 6.00
Ncm/amp 3.46 5.25 4.24
Voltage Constant V/kRPM 3.66 5 4.44
V/rad/sec 0.035 0.048 0.0424
Length (“L” above) inches 3.25 3.77 4.27
mm 82.63 95.76 108.46
Weight lb. 1.7 3 TBD
kg 0.776 1.359
Shaft Diameter (“D” above) inches .3152 .281 .281
mm 8.0060 7.137 7.137
Shaft Length (“S” above) inches 1.87 3.50/3.50 1.37
mm 47.50 88.90/88.90 34.75
Drive Electronics Internal or External Internal External External
Electronic Drive Part Number 48129-03 48129-11
NOTES
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
3.0M99
3.0” (79mm) Diameter, 4 Pole, Brushless DC Motor
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
*Part Number 150007 has a dual shaft.
9
3.0” (79mm) Diameter, 4 Pole, Brushless DC Motor
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will
vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support
applications. AMETEK reserves the right to revise its products without notification.
3.0M99
External Drive Part Number
48129-03 External Drive Part Number
48129-11
10
Motor Data Unit of Part Numbers
Measure 119050* 119051 119052 119053* 119054 119055 119056 119057 119058*
No Load Speed, Nominal RPM 4319 5259 4067 3434 2838 2543 2281 2021 1856
No Load Current, Nominal amps 1.48 1.74 1.41 1.24 1.07 0.99 0.92 0.85 0.80
Stall Tor que, Theoretical oz.-in. 28 4 37 5 4 28 45 3 4 96 505 51 8 541 5 49
Ncm 201 265 302 320 350 357 366 382 387
Continuous Torque oz.-in. 22 36 49 63 77 91 105 119 132
Ncm 16 25 35 44 54 64 74 84 93
Speed @ T o rque, Nominal RP M 3715 4342 3265 2641 2174 1864 1605 1377 1214
Current @ Torque, Nominal amps 4.4 7.6 7.6 7.9 7.8 8.1 8.3 8.3 8.4
Continuous Power , Max. watts out 6 0 116 118 12 3 12 4 12 6 12 5 121 11 9
Torque Constant oz.-in. /amp 7.52 6.17 7.98 9.45 11.44 12.77 14.23 16.06 17.49
Ncm/amp 5.31 4.36 5.64 6.68 8.08 9.02 10.05 11.34 12.35
Voltage Constant V/kRPM 5.56 4.56 5.90 6.99 8.46 9.44 10.52 11.88 12.93
V/rad/sec 0.0531 0.0436 0.0564 0.0667 0.0808 0.0901 0.1005 0.1134 0.1235
Electrical Time Constant millisecond 1.055 1.052 1.140 1.205 1.256 1.297 1.331 1.358 1.382
Mechanical Time Constant millisecond 14.713 13.065 12.005 10.293 11.253 10.283 9.413 9.313 8.754
Motor Constant oz.-in./(watt^.5) 11.5 12.5 15.0 16.6 19.0 20.1 21.4 23.1 24.1
Ncm/(watt^.5) 8.1 8.9 10.6 11.7 13.4 14.2 15.1 16.3 17.0
Rotor Inertia oz.-in.sec20.0138 0.0145 0.0191 0.0201 0.0286 0.0293 0.0303 0.0350 0.0360
Ncm-sec^2 0.0097 0.0102 0.0135 0.0142 0.0202 0.0207 0.0214 0.0247 0.0254
Terminal Resistance ohms 0.425 0.242 0.283 0.323 0.363 0.404 0.444 0.485 0.525
Terminal Inductance millihenry 0.449 0.255 0.322 0.389 0.457 0.524 0.591 0.658 0.726
Thermal Resistance ºC/W 1.21 1.19 1.17 1.15 1.13 1.11 1.09 1.06 1.04
Length (“L” above) inches 2.500 2.500 3.000 3.000 3.750 3.750 3.750 4.250 4.250
mm 63.50 63.50 76.20 76.20 95.25 95.25 95.25 107.95 107.95
Weight lb. 2.10 2.25 2.80 3.00 3.75 4.00 4.20 4.70 4.85
kg 0.95 1.02 1.27 1.36 1.70 1.81 1.90 2.13 2.20
Shaft Length (“S” above) inches .750 .750 .750 .750 1.500 1.500 1.500 1.875 1.875
mm 19.05 19.05 19.05 19.05 38.10 38.10 38.10 47.63 47.63
NOTES
* Motors require brushless motor controller for operation, refer to the controller section (page 45) for applicable controllers.
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
3.55M99
3.55” (90mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
11
3.55” (90mm) Diameter, 8 Pole, Brushless DC Motor 24 VDC
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will
vary depending on the operating environment and application. AMETEK RTMD products are not designed for and should not be used in medical life support
applications. AMETEK reserves the right to revise its products without notification.
3.55M99
12
Motor Data Unit of Part Numbers
Measure 071033 071070 071031 071145
Voltage Input Volts DC 12 13.8 74 27.6
No Load Speed, Nominal RP M 6700 3750 3700 3000
No Load Current, Nominal amps 1 2.5 0.22 0.5
Stall Tor que, Theoretical oz.-in. 7 2 21 0 334 45 3
Ncm 51 148 236 320
Continuous T orque oz.-in. 28 60 85 100
Ncm 20 42 60 71
Speed @ T o rque, Nominal RP M 4500 2527 2700 2100
Current @ Torque, Nominal amps 1 4 14.3 3.2 8
Continuous Power watts 94 113 171 155
T or que Constant oz.-in. /amp 2.42 4.98 27.04 12.44
Ncm/amp 1.71 3.51 19.10 8.79
Voltage Constant V/kRPM 1.79 3.68 20 9.20
V/rad/sec 0.0171 0.0351 0.1910 0.0879
Length (“L” above) inches 5.33 6.08 6.68 7.68
mm 135.38 154.43 169.67 195.07
Weight lb. 6.4 7.3 8.0 9.3
kg 2.9 3.3 3.6 4.2
Shaft Diameter (“D” above) inches .2495 .6250 .312 .4997
mm 6.337 15.8750 7.925 12.6924
Shaft Length (“S” above) inches .83 1.00 1.65 2.25
mm 21.08 25.40 41.91 57.15
Drive Electronics Internal Internal Internal Internal
NOTES
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
3.9M99
3.9” (99mm) Diameter, 4 Pole, Brushless DC Motor
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
13
3.9” (99mm) Diameter, 4 Pole, Brushless DC Motor
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will
vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support
applications. AMETEK reserves the right to revise its products without notification.
3.9M99
14
Motor Data Unit of Part Numbers
Measure 528512 071087 071190 524647 *524506
Voltage Input Volts DC 27.6 27 27 74 2 7
No Load Speed, Nominal RP M 4055 1935 1765 2565 2000
No Load Current, Nominal amps 1.6 0.8 0.7 0.62 2.5
Stall Tor que, Theoretical oz.-in. 2403 4380 6400 18000 15383
Ncm 1697 3094 4519 12707 10862
Continuous Torque oz.-in. 192 368 560 720 832
Ncm 136 260 395 508 587
Speed @ T o rque, Nominal RP M 3250 1573 1445 2253 1750
Current @ Torque, Nominal amps 23 2 0 27.5 18.5 46.0
Continuous Power watts 467 433 605 1214 1090
Torque Constant oz.-in. /amp 9.20 18.85 20.68 39.01 18.25
Ncm/amp 6.21 13.31 14.61 27.55 12.89
Voltage Constant V/kRPM 6.81 13.94 15.30 28.85 13.50
V/rad/sec 0.0621 0.1331 0.1461 0.2755 0.1289
Length (“L” above) inches 6.76 7.86 10.36 8.91 10.09
mm 171.70 199.64 263.14 226.31 256.29
Weight lb. 18 20 23 24 27
kg 8.2 9.1 10.4 10.9 12.2
Shaft Diameter (“D” above) inches .3747 .6250 .7497 .7497 .6250
mm 9.5174 15.8750 19.0424 19.0424 15.8750
Shaft Length (“S” above) inches 1.00 2.06 3.25 7.09 2.05/2.05
mm 25.40 52.32 82.55 180.09 52.07/52.07
Drive Electronics Internal or External Internal Internal Internal External External
Drive Electronics Part Number N /A N /A N /A 524731 524508
NOTES
* Motor design characteristics are based on an operating environment of 25ºC.
* Nominal and maximum performance figures are based on a winding temperature of 105ºC.
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK RTMD products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK RTMD Marketing and Sales.
5.25M99
5.25” (133mm) Diameter, 4 Pole, Brushless DC Motor
This drawing is a general outline. For a more detailed drawing please contact AMETEK Rotron.
*Part Number 524506 has a dual shaft.
15
5.25” (133mm) Diameter, 4 Pole, Brushless DC Motor
This document is for informal purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will
vary depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support
applications. AMETEK reserves the right to revise its products without notification.
5.25M99
External Drive Part Number
524731
524508
16
2.9” (74mm) BLDC Low-Voltage Blower 12/24 VDC
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
2.9BLV99
Blower Data Unit of Part Number
Measure 119495 119496
Voltage Input V D C 12 24
Stages 11
Pressure, Max. (Sealed Pressure) in. H2O, Sealed 3.4 3.4
mBar 8.4 8.4
Flow Rate, Max. (Open Flow) CFM 2 2 2 2
L/sec 10.4 10.4
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 3.4 3.4
4 CFM in. H2O 3.1 3.1
8 CFM in. H2O 2.9 2.9
12 CFM in. H2O 2.5 2.5
16 CFM in. H2O 1.8 1.8
17
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
2.9” (74mm) BLDC Low-Voltage Blower 12/24 VDC
2.9BLV99
18
Blower Data Unit of Part Number
Measure 119349*119350*
Voltage Input V D C 12 24
Stages 11
Pressure, Max. (Sealed Pressure) in. H2O, Sealed 10 1 0
mBar 24.9 24.9
Flow Rate, Max. (Open Flow) CFM 1 8 1 8
L/sec 8.5 8.5
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O10 10
4 CFM in. H2O 9.1 9.1
8 CFM in. H2O 7.6 7.6
12 CFM in. H2O 5.4 5.4
16 CFM in. H2O 2.4 2.4
18 CFM in. H2O0 0
3.0” (76mm) BLDC Low-Voltage Blower 12/24 VDC
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
3BLV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
19
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
3.0” (76mm) BLDC Low-Voltage Blower 12/24 VDC
3BLV99
20
3.3” (84mm) BLDC Low-Voltage Blower 12/24 VDC
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
3.3BLV99
Blower Data Unit of Part Number
Measure 119497 119498
Voltage Input V D C 12 24
Stages 11
Pressure, Max. (Sealed Pressure) in. H2O, Sealed 27.3 27.3
mBar 67.9 67.9
Flow Rate, Max. (Open Flow) CFM 7.5 7.5
L/sec 3.5 3.5
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 27.0 27.0
2 CFM in. H2O 26.0 26.0
4 CFM in. H2O 20.5 20.5
6 CFM in. H2O 9.0 9.0
8 CFM in. H2O0 0
21
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
3.3” (84mm) BLDC Low-Voltage Blower 12/24 VDC
3.3BLV99
22
4.5” (114mm) BLDC Low-Voltage Blower 12/24 VDC
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Speed is controlled by input voltage.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
4.5BLV99
Blower Data Unit of Part Number
Measure 119494 119395
Voltage Input V D C 12 24
Stages 11
Pressure, Max. (Sealed Pressure) in. H2O, Sealed 28.4 28.4
mBar 70.7 70.7
Flow Rate, Max. (Open Flow) CFM 9.1 9.1
L/sec 4.3 4.3
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 28.4 28.4
2 CFM in. H2O 26.2 26.2
4 CFM in. H2O 22.4 22.4
6 CFM in. H2O 15.3 15.3
8 CFM in. H2O 5.6 5.6
10 CFM in. H2O0 0
23
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
4.5” (114mm) BLDC Low-Voltage Blower 12/24 VDC
4.5BLV99
24
Part Number
Unit Standard Flow High Output
Blower Data Measure 119381 M 119384 M 119378 M
119380 119382 E 119383 119385 E 119375 119379 E
Voltage Input V D C 12 12 24 2 4 24 2 4
Stages 1 1 1 1 1 1
Pressure, Max. (Sealed Pressure) in. H2O1212 12 1224 24
mBar 30 30 30 30 60 60
Flow Rate, Max. (Open Flow) C FM 3 4 3 4 3 4 34 4 5 4 5
L/sec 16 16 16 16 21 21
Drive Electronics Internal or External External Internal External Internal External Internal
T ypical Performance Points
Air Flow Pressure
0 CFM in. H2O 12.5 12.5 12.5 12.5 24.3 24.3
10 CFM in. H2O 11.7 11.7 11.7 11.7 22.0 22.0
20 CFM in. H2O 7.6 7.6 7.6 7.6 18.4 18.4
30 CFM in. H2O 2.3 2.3 2.3 2.3 10.8 10.8
40 CFM in. H2O3.5 3.5
5.0” (127mm) BLDC Low-Voltage Blower 12/24 VDC
NOTES:
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max.
Speed Control: Internal – E (Electrical): Pulse Width Modulated or Analog input voltage (User Supplied), 0 to 5 Volts DC Nominal
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed.
External - These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and speed
control. AMETEK blower controller part numbers 48069 for 12VDC blowers and 48070 for 24 VDC blowers are design for use with the
above blowers.
5BLV99
25
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.0” (127mm) BLDC Low-Voltage Blower 12/24 VDC
5BLV99
26
5.1” (130mm) BLDC Low-Voltage Blower 12/24 VDC
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection.
Input voltages listed in the chart above indicate the controller input voltage requirement.
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.
Speed Control: Via 0.5 VDC analog signal or potentiometer setting at controller.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
5.1BLV99
Blower Data Unit of Part Number
Measure 119396 119397
Voltage Input V D C 12 24
Stages 11
Pressure, Max. (Sealed Pressure) in. H2O, Sealed 25.70 25.70
mBar 64 64
Flow Rate, Max. (Open Flow) CFM 15.30 15.30
L/sec 7.22 7.22
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 25.7 25.7
2 CFM in. H2O 23.8 23.8
4 CFM in. H2O 21.7 21.7
6 CFM in. H2O 19.5 19.5
8 CFM in. H2O 16.5 16.5
10 CFM in. H2O 12.0 12.0
12 CFM in. H2O 7.1 7.1
14 CFM in. H2O 2.2 2.2
16 CFM in. H2O0 0
27
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.1” (130mm) BLDC Low-Voltage Blower 12/24 VDC
5.1BLV99
28
Blower Data Unit of Part Numbers
Measure 116521*116522 116450*
Voltage Input V D C 24 24 24
Stages 12 3
Vacuum, Max. (Sealed Vacuum) in. H2O 6 20 24
mBar 15 50 60
Pressure, Max. (Sealed Pressure) in. H2O, sealed 8.2 22 26
mBar 20 55 64
Flow Rate, Max. (Open Flow) CFM 39 3 5 3 8
L/sec 18 17 18
Length Dimension “L” inches 2.65 3.66 4.56
mm 67.31 92.96 115.82
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 8.2 35.7 26.0
5 CFM in. H2O 8.0 18.1 23.0
10 CFM in. H2O 7.6 15.5 22.0
15 CFM in. H2O 7.2 12.8 20.5
20 CFM in. H2O 6.3 10.0 17.5
25 CFM in. H2O 5.0 6.3 13.0
30 CFM in. H2O 3.3 4.0 8.5
35 CFM in. H2O 1.7 0.10 3.0
5.7” (145mm) BLDC Low-Voltage Blower 24 VDC
Input voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section of this catalog for proper controller selection.
Input voltages listed in the chart above indicate the controller input voltage requirement.
Input current: 6-10 Amps, Current is dependent on blower model.
Temperature: Working Air: 0o C to 45°C, Ambient Air: 0o C to 45°C, Storage Air: -40o C to 85°C
Dielectric T esting: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamp leakage max.
Speed Control: Speed control is achieved at the blower controller. Refer to the controller section (PAGE 45) of this catalog for proper controller operation.
NOTES:
* This document is for informational purposes only and should not be considered as a binding description of the products and their performance in all applications.
* AMETEK Rotron products are not designed for and should not be used in medical life support applications.
* AMETEK reserves the right to revise its products without notification.
* The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales.
5.7BLV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
29
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.7” (145mm) BLDC Low-Voltage Blower 24 VDC
5.7BLV99
30
5.7” (145mm) BLDC Thru Flow Blower 250 WATT, 120 VOLT
Part Number
Standard Flow High Flow
Blower Data Unit of 116626 M 116627 M 116628 M 116644 M 116645 M 116646 M
Measure 116629 E*116630 E*116631 E 116647 E 116648 E 116649 E
Stages 1 2 3 1 2 3
Vacuum, Max. (Sealed Vacuum) in. H2O29 50 7024 3445
mBar 72 124 174 60 84 112
Pressure, Max. (Sealed Pressure) in. H2O32 52 7527 3750
mBar 79 129 186 67 92 124
Flow Rate, Max. (Open Flow) C FM 67 62 4 6 117 90 8 0
L/sec 32 29 22 55 42 38
Inlet/Outlet Diameter inches 1.25 1.25 1.25 1.75 1.75 1.75
mm 31.75 31.75 31.75 44.45 44.45 44.45
Length (Dimension “I” above) inches 0.74 1.65 2.5 0.76 1.88 1.75
mm 18.80 41.91 63.50 19.30 47.75 44.45
Length (Dimension “L” above) inches 3.21 4.12 5.02 3.28 4.33 5.34
mm 81.53 104.65 127.51 83.31 109.98 135.64
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 32.0 52.2 75.0 27.0 37.1 50.0
10 CFM in. H2O 30.0 44.5 52.2 26.1 34.1 46.3
20 CFM in. H2O 28.1 42.3 34.2 25.3 31.7 42.0
30 CFM in. H2O 24.3 31.8 21.5 23.3 28.9 35.9
40 CFM in. H2O 19.0 21.8 8.0 23.0 25.9 28.6
50 CFM in. H2O 12.5 11.7 21.4 21.4 21.9
60 CFM in. H2O 6.0 18.0 17.8 15.6
70 CFM in. H2O 16.7 12.4 7.5
80 CFM in. H2O 13.9 5.7 0
90 CFM in. H2O 10.2 .09
100 CFM in. H2O 6.1
110 CFM in. H2O 2.6
NOTES:
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7/250TFBHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
31
5.7” (145mm) BLDC Thru Flow Blower 250 WATT, 120 VOLT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb ./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403. Canadian Standards Association is qualified per
C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
5.7/250TFBHV99
32
Part Number
Standard Flow High Flow
Blower Data Unit of 116634 M*116633 M 116632 M*116637 M*116636 M*116635 M
Measure 116640 E*116639 E 116638 E*116643 E*116642 E*116641 E
Stages 1 2 3 1 2 3
Vacuum, Max. (Sealed Vacuum) in. H2O 29 48 65 26 57.5 42
mBar 72 119 161 64 143 104
Pressure, Max. (Sealed Pressure) in. H2O 32 56 76 27 68.0 46
mBar 79 139 188 67 169 114
Flow Rate, Max. (Open Flow) C FM 68 63 4 9 11 5 110 8 0
L/sec 32 30 23 54 52 38
Inlet/Outlet Diameter inches 1.25 1.25 1.25 1.75 1.75 1.75
mm 31.75 31.75 31.75 44.45 44.45 44.45
Length (Dimension “I” above) inches 0.33 1.25 2.14 0.47 1.53 2.53
mm 8.38 31.75 54.36 11.94 38.86 64.26
Length (Dimension “L” above) inches 5.08 6.35 6.89 5.22 6.27 7.28
mm 129.03 161.29 175.01 132.59 159.26 184.91
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 31.8 56.1 76.2 27.1 48.1 46.0
10 CFM in. H2O 28.7 48.0 60.3 25.0 44.0 42.8
20 CFM in. H2O 27.7 44.3 44.1 24.4 41.6 39.2
30 CFM in. H2O 24.7 38.1 28.9 22.9 37.9 34.9
40 CFM in. H2O 20.1 28.9 16.1 21.2 32.2 30.0
50 CFM in. H2O 14.5 18.2 19.1 25.8 24.3
60 CFM in. H2O 7.3 4.2 17.2 20.5 16.2
70 CFM in. H2O 15.0 15.8 9.8
80 CFM in. H2O 12.2 7.1
90 CFM in. H2O 8.0
100 CFM in. H2O 5.5
5.7” (145mm) BLDC Bypass Blower 250 WATT, 120 VOLT
NOTES:
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7/250BHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
33
5.7” (145mm) BLDC Bypass Blower 250 WATT, 120 VOLT
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per
C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp
housing #640250-6 (to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.7/250BHV99
34
Part Number
Standard Flow
Blower Data Unit of
117629 E*117630 E*
Stages
Measure
12
Vacuum, Max. (Sealed Vacuum) in. H2O28 47
mBar 69 117
Pressure, Max. (Sealed Pressure) in. H 2O31 50
mBar 77 124
Flow Rate, Max. (Open Flow) CF M 6 7 6 5
L/sec 32 31
Length (Dimension “I” above) inches .69 1.60
mm 17.53 40.64
Length (Dimension “L” above) inches 3.21 4.12
mm 81.53 104.65
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 31.1 50.5
10 CFM in. H2O 26.8 45.4
20 CFM in. H2O 23.8 40.9
30 CFM in. H2O 20.5 33.7
40 CFM in. H2O 15.8 25.3
50 CFM in. H2O 10.0 16.0
60 CFM in. H2O 4.4 6.46
70 CFM in. H2O
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7” (145mm) BLDC Thru Flow Blower 400 WATT, 240 VOLT
5.7/400TFBHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
35
Regulatory Agency Certification: Underwriters Laboratories, Inc. is qualified per UL507 under File E-94403; Canadian Standards Association is qualified per
C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp
housing #350809-1 (to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.7” (145mm) BLDC Thru Flow Blower 400 WATT, 240 VOLT
5.7/400TFBHV99
36
Part Number
Standard Flow High Flow
Blower Data Unit of 117634 M*117633 M 117632 M*117637 M*117636 M*117635 M*
Measure 117640 E*117639 E 117638 E*117643 E *117642 E*117641 E*
Stages 1 2 3 1 2 3
Vacuum, Max. (Sealed Vacuum) in. H2O2845 60233953
mBar 69 112 149 57 97 131
Pressure, Max. (Sealed Pressure) n. H2O3051 70254561
mBar 74 126 174 62 112 151
Flow Rate, Max. (Open Flow) C FM 69 62 5 8 11 4 9 7 8 6
L/sec 33 29 27 54 46 41
Inlet/Outlet Diameter inches 1.25 1.25 1.25 1.75 1.75 1.75
mm 31.75 31.75 31.75 44.45 44.45 44.45
Length (Dimension “I” above) inches 2.53 1.25 2.14 .47 1.53 2.53
mm 64.26 31.75 54.36 11.94 38.86 64.26
Length (Dimension “L” above) inches 5.08 5.99 6.89 5.22 6.27 7.28
mm 129.03 152.15 175.01 132.59 159.26 184.91
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 30.3 51.0 69.9 24.8 44.6 61.5
10 CFM in. H2O 27.9 44.2 59.9 23.6 41.0 55.8
20 CFM in. H2O 26.2 41.8 52.8 22.6 39.8 51.5
30 CFM in. H2O 23.6 35.9 44.1 21.5 35.8 46.0
40 CFM in. H2O 19.0 27.8 32.1 19.5 32.0 40.1
50 CFM in. H2O 13.3 16.6 18.1 17.9 28.0 34.2
60 CFM in. H2O 7.0 3.7 16.1 23.9 28.2
70 CFM in. H2O 3.7 13.8 17.9 19.6
80 CFM in. H2O 12.0 12.1 8.1
90 CFM in. H2O 8.7 0
100 CFM in. H2O 6.7
110 CFM in. H2O0
5.7” (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7/400BHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
37
5.7” (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. R0097184.
Underwriters Laboratories, Inc. Qualified per UL507 under File E-94403. Canadian Standards Association Qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles. Amp
housing #1-480763-0 (to be supplied by customer), mates with post header assembly.
*IEC 801 testing has been completed, and specific data can be provided upon request.
5.7/400BHV99
38
Part Number
Standard Flow High Flow Ultra Flow
Blower Data Unit of 117418 M*119102 M*119104 M*
Measure 117417 E*119101 E*119103 E*119105 E*
Stages 3 1 2 1
Vacuum, Max. (Sealed Vacuum) in. H2O 106 41 71 26
mBar 263 102 176 64
Pressure, Max. (Sealed Pressure) in. H2O 115 44 76 29
mBar 285 109 188 72
Flow Rate, Max. (Open Flow) C FM 67 1 6 1 11 9 2 4 2
L/sec 32 76 56 114
Inlet/Outlet Diameter inches 1.25 1.75 1.75 2.75/2.50
mm 31.75 44.45 44.45 69.85/63.50
Length (Dimension “I” above) inches 2.12 .47 1.53 .71
mm 53.85 11.94 38.86 18.03
Length (Dimension “L” above) inches 6.87 5.30 6.35 5.46
mm 174.50 134.62 161.29 138.68
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 115.8 44.1 76.2 29.3
20 CFM in. H2O 86.6 41.8 68.4 27.5
40 CFM in. H2O 54.9 39.2 57.2 26.1
60 CFM in. H2O 18.3 34.1 43.5 23.5
80 CFM in. H2O 29.0 33.2 21.6
100 CFM in. H2O 23.3 19.8 17.6
120 CFM in. H2O 14.4 0 15.8
140 CFM in. H2O 7.0 14.1
160 CFM in. H2O 0 11.2
180 CFM in. H2O8.2
200 CFM in. H2O5.5
220 CFM in. H2O2.8
240 CFM in. H2O1.2
5.7” (145mm) BLDC Bypass Blower 800 WATT, 120 VOLT
NOTES:
Nominal input voltage: 120 Volts AC RMS +/- 10%, 60Hz
Input current: 10 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
5.7/800BHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
39
5.7” (145mm) BLDC Bypass Blower 800 WATT, 120 VOLT
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under Licence No. R9571008; Underwriters Laboratories, Inc. is
qualified per UL507 under File E-94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350810-1(to be supplied by customer), mates with post header assembly.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.7/800BHV99
40
5.7” (145mm) DC Bypass Blower 1200 WATT, 240 VOLT
Part Number
Standard Flow High Flow Ultra Flow
Blower Data Unit of 117416 M*119152 M*119154 M*
Measure 117415 E*119151 E*119153 E* 119155 E*
Stages 3 1 2 1
Vacuum, Max. (Sealed Vacuum) in. H2O 135 50 91 33
mBar 335 124 226 82
Pressure, Max. (Sealed Pressure) in. H2O 144 54 97 39
mBar 357 134 241 97
Flow Rate, Max. (Open Flow) CF M 82 1 9 0 156 3 0 7
L/sec 39 90 74 145
Inlet/Outlet Diameter inches 1.25 1.75 1.75 2.75/2.50
mm 31.75 44.45 44.45 69.85/63.50
Length (Dimension “I” above) inches 2.12 .47 1.53 .70
mm 53.85 11.94 38.86 17.78
Length (Dimension “L” above) inches 6.87 5.11 6.35 5.47
mm 174.50 128.77 161.29 138.94
Typical Performance Points
Air Flow Pressure
0 CFM in. H2O 144.3 54.0 97.0 39.2
20 CFM in. H2O 129.1 53.9 92.5 38.0
40 CFM in. H2O 102.9 51.1 85.8 37.5
60 CFM in. H2O 60.8 47.0 75.9 35.3
80 CFM in. H2O 10.8 43.2 62.3 33.5
100 CFM in. H2O 37.0 40.5 31.4
120 CFM in. H2O 29.4 32.1 28.0
140 CFM in. H2O 22.3 15.0 25.4
160 CFM in. H2O 14.2 21.5
180 CFM in. H2O18.5
200 CFM in. H2O16.1
220 CFM in. H2O13.1
240 CFM in. H2O10.0
260 CFM in. H2O7.4
280 CFM in. H2O4.3
300 CFM in. H2O1.0
NOTES:
Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz
Input current: 5 amps AC RMS maximum
Temperature: Working Air: 0o C to 50°C, Ambient Air: 0o C to 50°C, Storage Air: -40o C to 85°C
Dielectric T esting: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
5.7/1200BHV99
*These part numbers are available through AMETEK Rotron distributors. See page 54 for distributor information.
41
5.7” (145mm) DC Bypass Blower 1200 WATT, 240 VOLT
Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is
qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448.
Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles.
Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.
*IEC 801 testing has been completed, and specific data can be provided upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92” Hg @ 70° F.).
Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or
corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed f or and should not be used in medical
life support applications. AMETEK reserves the right to revise its products without notification.
5.7/1200BHV99
NOTES (continued):
Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC
Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection)
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment.
42
Blower Contollers
Controller Data 48132
Max Continuous Current 5 A
Input Voltage Range 11-52 VDC
Controller PWM Frequency 25 kHz
Analog Speed Input 0-5 VDC
Electrical Hall Spacing 600 or 1200
Waveform 8-Step T rapezoidal
Current Limit Protection Yes
Rotation CW / CCW
5 Amp BLDC Blower Controller
NOTES:
Temperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by
adjusting the potentiometer when J6 is in position 1 to 2.
Current Control: Trip point is at 5 Amp maximum.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary
depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications.
AMETEK reserves the right to revise its products without notification.
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings: J6 Set to position 1-2 for internal speed adjust.
Set to position 2-3 for analog speed input voltage.
J3 Disable or enable to determine forward/reverse rotation.
J2 Disable for 60° electrical spacing.
Enable for 120° electrical spacing.
J5 Set position 1-2 for 16-52 VDC
Set position 2-3 for 11-16 VDC
5BC99
J1-1 Vin J4-1 Motor Phase A
J1-2 Vin Return (Gnd) J4-2 Motor Phase C
J1-3 Analog Speed In J4-3 Hall - (Gnd)
J4-4 Hall 1
J4-5 Hall 2
J4-6 Hall 3
J4-7 Hall + (+12V)
J4-8 Motor Phase B
43
10 Amp BLDC Blower Controller
5BC99
Blower Contollers
Controller Data 48133
Max Continuous Current 10 A
Input Voltage Range 11-52 VDC
Controller PWM Frequency 25 kHz
Analog Speed Input 0-5 VDC
Electrical Hall Spacing 600 or 1200
Waveform 8-Step T rapezoidal
Current Limit Protection Yes
Rotation CW / CCW
NOTES:
T emperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved by
adjusting the potentiometer when J6 is in position 1to 2.
Current Control: Trip point is at 10 Amp maximum.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary
depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications.
AMETEK reserves the right to revise its products without notification.
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings: J6 Set to position 1-2 for internal speed adjust.
Set to position 2-3 for analog speed input voltage.
J3 Disable or enable to determine forward/reverse rotation.
J2 Disable for 60° electrical spacing.
Enable for 120° electrical spacing.
J5 Set position 1-2 for 16-52 VDC
Set position 2-3 for 11-16 VDC
J1-1 Vin J4-1 Phase C
J1-2 Gnd J4-2 Phase B
J1-3 Analog Speed In J4-3 Phase A
J4-4 Hall - (Gnd)
J4-5 Hall + (+12V)
J4-6 Hall 1
J4-7 Hall 2
J4-8 Hall 3
44
20 Amp BLDC Motor Controller
20MC99
Motor Contoller
Controller Data 48134
Max Continuous Current 20 A
Input Voltage Range 11-52 VDC
Controller PWM Frequency 25 kHz
Analog Speed Input 0-5 VDC
Electrical Hall Spacing 600 or 1200
Waveform 8-Step T rapezoidal
Current Limit Protection Yes
Rotation CW / CCW
NOTES:
T emperature: Operating: 0o C to 50°C, Storage Air: -40o C to 85°C
Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is achieved by
adjusting the potentiometer when J6 is in position 1 to 2.
Current Control: Trip point is at 20 Amp maximum.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using constant DC voltages. Actual performance will vary
depending on the operating environment and application. AMETEK Rotron products are not designed for and should not be used in medical life support applications.
AMETEK reserves the right to revise its products without notification.
Caution should be taken. Misplacement of jumper setting will destroy the control.
Jumper Settings: J5 Set to position 1-2 for 16-52 VDC operation.
Set to position 2-3 for 11-16 VDC operation.
J6 Set to position 1-2 for internal speed adjust.
Set to position 2-3 for analog speed input voltage.
J3 Disable or enable to determine forward/reverse rotation.
J2 Disable for 60° electrical spacing.
Enable for 120° electrical spacing.
J4-6 Brake J4-12 Analog/In J1-1 Vin
J4-5 Hall + J4-11 Freq. Out J1-2 Phase A
J4-4 Hall 3 J4-10 For./Rev. J1-3 Phase B
J4-3 Hall 2 J4-9 Output Enable J1-4 Phase C
J4-2 Hall 1 J4-8 Vref J1-5 Ground
J4-1 Gnd J4-7 Ground
45
BLDC Motor/Blower Controller Numbers
MBCP99
Motor/Blower Controller Mating Cable
Part Part From Controller Input
Numbers Numbers to Blower/Motor Power Cable
119272 48134 N/A N/A
119275 48134 N/A N/A
119000 48134 39831 or 39817* N /A
119001 48134 39831 or 39817* N /A
119002 48134 39831 or 39817* N /A
119003 48134 39831 or 39817* N /A
119004 48134 39831 or 39817* N /A
119005 48134 39831 or 39817* N /A
119006 48134 39831 or 39817* N /A
119007 48134 39831 or 39817* N /A
119008 48134 39831 or 39817* N /A
119050 48134 39831 or 39817* N /A
119051 48134 39831 or 39817* N /A
119052 48134 39831 or 39817* N /A
119053 48134 39831 or 39817* N /A
119054 48134 39831 or 39817* N /A
119055 48134 39831 or 39817* N /A
119056 48134 39831 or 39817* N /A
119057 48134 39831 or 39817* N /A
119058 48134 39831 or 39817* N /A
119375 48133 39851 39773
119380 48133 39851 39773
119383 48133 39851 39773
119381 N/A N/A 39773
119382 N/A N/A 39773
119384 N/A N/A 39773
119385 N/A N/A 39773
119378 N/A N/A 39773
119379 N/A N/A 39773
119396 48134 N/A N/A
119397 48134 N/A N/A
116521 48133 N/A 39773
116522 48133 N/A 39773
116450 48133 N/A 39773
117007** 48132 39685 39773
117011** 48132 39685 39773
119319** 48132 39685 39773
119317** 48132 39685 39773
Cable mm inches
39831 457.2±12.7 18.00±.50
39817 457.2 ±12.7 18.00±.50
39817-1 609.6±12.7 24.00±.50
39817-2 304.8±12.7 12.00+.50
39851 152.4±12.7 6.00±.50
39851-1 304.8±3.0 12.00±.12
39851-2 457.2±3.0 18.00±.12
39851-3 609.6±3.0 24.00±.12
39685 145.0±3.0 5.71±.12
39685-1 292.1±3.0 11.50±.12
39685-2 241.3±3.0 9.50±.12
39685-3 304.8±12.7 12.00±.50
39685-4 457.2±12.7 18.00±.50
39685-5 609.6±12.7 24.00±.50
39773 368.3±12.7 14.50±.50
39773-1 304.8±12.7 12.00±.50
39773-2 457.2±12.7 18.00±.50
39773-3 609.6±12.7 24.00±.50
* Cable 39831 transfers hall signals from the motor to the controller. Cable 39817 does the same, but also provides cabling for analog input, tach output,
braking, forward/reverse, enable/disable, and voltage reference of a nominal 6.25 VDC at a maximum of 10 mAmp.
** Earlier versions of the 5.0" Minijammer blower.
DATE
COMPANY
ADDRESS
CITY STATE ZIP
NAME
TITLE DEPT.
TELEPHONE FAX
Blower Sizing
PLEASE COMPLETE THIS FORM AND F AX IT TO (330) 678-8227,
A TTENTION: ROTRON MARKETING DEP ARTMENT
46
Purpose of product which blower is to
be incorporated in
Describe general operation
Estimated annual requirements
Power Supply V DC VAC
Air Flow Requirements To C FM
Pressure Requirements To In. H2O
Standard Operating Point:
Pressure or Vacuum In. H2O, Flow C F M
Surrounding Temperature:
Min. o F Max. o F
Humidity
Agency Requirements:
ISO9001 UL TUV CSA Other
Expected Life Hours
Production Delivery Date
Expected Price Range
If Replacement
Current Manufacturer
Model
Purpose of product which motor is to
be incorporated in
Describe general operation
Estimated annual requirements
Power Supply VDC Other
Speed Requirements To RP M
Maximum Continuous Performace Requirement
Speed RPM
Tor q ue Oz. In.
Power HP
Dimension, Max.:
Diameter Inches, Length Inches
Surrounding Temperature:
Min. o F Max. o F
Humidity
Expected Life Hours
Production Delivery Date
Expected Price Range
If Replacement
Current Manufacturer
Model
Motor Sizing
Complete applicable side for additional information.
AE99
Throughout our catalog, you will find terminology
used for air moving selection and product sizing.
Below are a few of the key terms:
Flow
Volume Rate/Time
AMETEK charts are in SCFM, m3/min, or L/S
SCFM = Standard Cubic Feet Per Minute
(American)
Air density = 0.075 lb/cubic foot
•M
3
/min = Cubic Meters Per Minute (Metric)
L/sec = Liters Per Second (Metric)
•1 m
3
/min = 35.3 SCFM
1 L/sec = 2.119 SCFM
See Standard Engineering Conversions for
other flows on pg. 44
Pressure
Force/Area
AMETEK charts are in In. H2O (IWG), PSIG,
MM of Water, IHG, or mbar
IWG = Inches of Water Gauge (American)
PSIG = Pounds Per Square Inch Gauge
(American)
mm of Water = Millimeter of Water Gauge
(Metric)
IHG = Inches of Mercury Gauge (American)
mbar = Millibar Gauge (Metric)
PSIA = Pounds Per Square Inch Absolute
(American)
27.7 IWG = 1 PSIG
703.58 MM of Water = 1 PSIG
2.036 IHG = 1 PSIG
0.069 Bars = 69 mbar = 1 PSIG
Standard Atmosphere = 0 PSIG = 14.7 PSIA
See Basic Fan Laws Chart for correcting
pressure due to speed or density changes
Density
Weight/Volume
Standard Air = 0.075 lb/cubic foot
Specific Gravity
Density Ratio Relative to Air
Standard Air SG = 1.0
Methane SG = 0.55
Velocity
Distance/Time or Flow/Area
FPM = Feet Per Minute (American)
M/min = Meters Per Minute (Metric)
See Standard Engineering Conversion Chart
for other velocities on pg. 44
Pressure Drop/Back Pressure/Impedance
Friction causes air to slow down and lost
energy is measured in pressure drop terms
Typical pressure drop areas include piping,
elbows, accessories and system
Each fixed system has a fixed system
impedance caused by a single or multiple
pressure drop points
Changing the system impedance will cause
the blower’s work point to change
47
48
Standard Engineering Conversions
AE99
MULTIPLY BY TO OBT AIN
Atmospheres 76.0 Cms. of Mercury
Atmospheres 29.92 Inches of Mercury
Atmospheres 406.8348 Inches of Water
Atmospheres 10,333 Kgs./Sq. Meter
Atmospheres 1.013 x 105Pascals
Atmospheres 14.70 Pounds/Sq. Inch
Atmospheres 760 Torrs
Bars 0.9869 Atmospheres
Bars 1. x 105Dynes/Sq. Cm.
Bars 1.020 x 104Kgs./Square Meter
Bars 14.50 Pounds/Sq. Inch
British Thermal Units 0.2520 Kilogram-Calories
British Thermal Units 777.5 Foot-Pounds
British Thermal Units 1054 Joules
British Thermal Units 107.5 Kilogram-Meters
British Thermal Units 2.928 x 10–4 Kilowatt-Hours
Centimeters of Mercury 0.01316 Atmospheres
Centimeters of Mercury 0.0372 Inches of Water
Centimeters of Mercury 136.0 Kgs./Square Meter
Centimeters of Mercury 0.1934 Pounds/Sq. Inch
Centimeters/Second 1.969 Feet/Minute
Centimeters/Second 0.6 Meters/Minute
Cubic Centimeters 3.531 x 10–5 Cubic Feet
Cubic Centimeters 6.102 x 10–2 Cubic Inches
Cubic Centimeters 10-6 Cubic Meters
Cubic Centimeters 10-3 Liters
Cubic Feet 2.832 x 104Cubic Cms.
Cubic Feet 1728 Cubic Inches
Cubic Feet 0.02832 Cubic Meters
Cubic Feet 0.03704 Cubic Yards
Cubic Feet 28.32 Liters
Cubic Feet/Minute 472.0 Cubic Cms./Sec.
Cubic Feet/Minute 1.6992 Cubic Meters/Hour
Cubic Feet/Minute .02832 Cubic Meters/Minute
Cubic Feet/Minute 28.32 Liters/Minute
Cubic Feet/Minute 0.4720 Liters/Second
Cubic Feet/Minute 62.4 Lbs. of Water/Min.
Cubic Inches 16.39 Cubic Centimeters
Cubic Inches 5.787 x 10–4 Cubic Feet
Cubic Inches 1.639 x 10–5 Cubic Meters
Cubic Meters 105 Cubic Centimeters
Cubic Meters 35.31 Cubic Feet
Cubic Meters 61,023 Cubic Inches
Cubic Meters/Hour .5885 Cubic Feet/Minute
Cubic Meters/Minute 35.3107 Cubic Feet/Minute
Feet 30.48 Centimeters
Feet 12 Inches
Feet 0.3048 Meters
Feet 1/3 Yards
Feet of Air
(1 atmosphere 60O F) 5.30 x 10–4 Pounds/Square Inch
Gallons 3.785 Liters
Grams/Cu. Cm. 62.43 Pounds/Cubic Foot
Horsepower 42.44 British Thermal Units/Min.
Horsepower 33,000 Foot-Pounds/Min.
Horsepower 10.70 Kg. Calories/Min.
Horsepower 745.7 Watts
Horsepower-Hours 2547 British Thermal Units
Inches 2.540 Centimeters
Inches 103Mils
Inches of Mercury 0.03342 Atmospheres
Inches of Mercury 13.60 Inches of Water
Inches of Mercury 3 45. 3 Kgs./Square Meter
Inches of Mercury 25.40 Mms. of Mercury
Inches of Mercury 0.4912 Pounds/Square In.
Inches of Water 0.002458 Atmospheres
Inches of Water 0.07355 Inches of Mercury
Inches of Water 25.40 Kgs./Square Meter
Inches of Water 2.4884 Millibars
Inches of Water 2 4 8. 8 Pascals
Inches of Water 5. 20 4 Pounds/Square Ft.
Inches of Water 0.03613 Pounds/Square In.
MULTIPLY BY TO OBT AIN
Kgs./Cubic Meter 0.06243 Pounds/Cubic Foot
Kilometers 3281 Feet
Kilowatts 56.92 British Thermal Units/Min.
Kilowatts 737.6 Foot-Pounds/Sec.
Kilowatts 1.341 Horsepower
Kilowatts 14.34 Kg.-Calories/Min.
Kilowatt-Hours 3415 British Thermal Units
Liters 103Cubic Centimeters
Liters 61.02 Cubic Inches
Liters 10–3 Cubic Meters
Liters .2642 Gallons
Liters/Minute .0353 Cubic Feet/Minute
Log10N 2.303 LogEN or Ln N
Log N or Ln N 0.4343 Log10N
Meters 100 Centimeters
Meters 3.2808 Feet
Meters 39.37 Inches
Meters 10–3 Kilometers
Meters 103Millimeters
Miles 5280 Feet
Miles 1.6093 Kilometers
Miles 1760 Yards
Millibars .4019 Inches of Water
Mms. of Mercury 0.0394 Inches of Mercury
Mms. of Mercury 1.3595–3 Kgs./Square Cm.
Mms. of Mercury 0.01934 Pounds/Square Inch
Newton Meters .7376 Pound-Force-Foot
Ounce - Force - Inch 0. 706 Newton - Centimeter
Ounce - Force - Inch 7.06 x 10–3 Newton - Meter
Ounce - Force - Inch 5.21 x 10–3 Pound - Force - Foot
Pascals .004 Inches of Water
Pints (Liq.) 2 8.87 Cubic Inches
Pints (U.S. liquid) 473,179 Cubic Centimeters
Pints (U.S. liquid) 16 Ounces (U.S. fluid)
Pounds 444,823 Dynes
Pounds 453.6 Grams
Pounds 16 Ounces
Pounds of Carbon to CO214,544 British Thermal Units (mean)
Pounds of Water 27 .68 Cubic Inches
Pounds of Water 0.1198 Gallons
Pounds of Water
Evaporated at 212O F 970.3 British Thermal Units
Pounds/Cubic Foot 16.02 Kgs./Cubic Meter
Pounds/Cubic Foot 4.882 Kgs./Square Meter
Pounds-Force-Foot 1.3558 Newton Meters
Pounds/Square Inch 0.06804 Atmospheres
Pounds/Square Inch 27.7 Inches of Water
Pounds/Square Inch 2.0 36 Inches of Mercury
Pounds/Square Inch 703 .1 Kgs./Square Meter
Pounds/Square Inch 6.895 x 103Pascals
Pounds/Square Inch 51.715 Millimeters of Mercury at 0O C
Square Centimeters 1.973 x 105Circular Mils
Square Centimeters 1.076 x 10–3 Square Feet
Square Centimeters 0.1550 Square Inches
Square Feet 929.0 Square Centimeters
Square Feet 0.09290 Square Meters
Square Inches 1.273 x 106Circular Mils
Square Inches 6. 4 5 2 Square Centimeters
Square Inches 6.944 x 10–3 Square Feet
Square Inches 10 6 Square Mils
Square Inches 64 5 . 2 Square Millimeters
Square Kilometers 10.76 x 106Square Feet
Square Kilometers 1.196 x 106Squar e Yards
Square Meters 10.764 Square Feet
Square Meters 1 .1 96 Square Yards
Temp. (OC) +273 1 Abs. Temp. (OC)
Temp. (OC) +17.8 1.8 Temp. ( OF)
Temp. (OF) +460 1 Abs. Temp. (OF)
Temp. (OF) -32 5/9 Temp. ( OC)
Watts 0.05692 British Thermal Units/Min.
Watts 107Ergs/Second
Watts 44.26 Foot-Pounds/Min.
Watts 1.341 x 10–3 Horsepower
Watts 0.01434 Kg.-Calories/Min.
Watts-Hours 3.415 British Thermal Units
Watts-Hours 1.341 x 10–3 Horsepower/Hours
49
Density Correction Chart
AE99
50 AE99
Physical Laws for Blower Applications
In the following formulae these symbols are used:
P-Pressure in pounds per square inch (PSI) or inches of
mercury column (inches Hg)
CFM-V olume in cubic feet per minute
RPM-Speed in revolutions per minute
D-Density in pounds per cubic foot (lbs./cu. ft.)
H-Height of air or gas column (ft.)
SG-Specific Gravity (ratio of density of gas to the density
of air)
“Standard Air”-Air at 68O F (absolute temperature 528O) and
29.92” Hg. (barometric pressure at sea level). The density of
such air is 0.075 lbs./cu. ft. and the specific volume is 13.29
cu. ft./lb. The specific gravity is 1.0.
The outlet pressure of a blower depends on the condition of
the air or gas at the inlet. The inlet condition is influenced by:
a-Specific gravity (the ratio of density of the gas to density
of standard air)
b-Altitude (location of blower)
c-Temperature of inlet air
Basic Fan Laws Chart
Volume
The V olume changes in direct ratio to the speed.
Example – A blower is operating at 3500 RPM and delivering
1000 CFM. If the speed is reduced to 3000 RPM, what is the
new volume?
V1 = Original Volume (1000 CFM)
V2 = New V olume
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
V2 = V1 ( RPM2 )1 = 1000 x ( 3000 )1 = 1000 x .857 = 857 CFM
RPM1 3500
Pressure
V ARIABLE VOLUME PRESSURE HORSEPOWER
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio Varies with CUBE of Speed Ratio
CFM2 = CFM1 ( RPM2 )P2 = P1 ( RPM2 ) 2HP2 = HP1 ( RPM2 ) 3
RPM1 RPM1 RPM1
WHEN DENSITY CHANGES Does Not Change Varies DIRECT with Density Ratio Varies DIRECT with Density Ratio
P2 = P1 ( D2 )HP2 = HP1 ( D2 )
D1 D1
Pressure (barometric) varies in direct proportion
to altitude.
Example – A blower is to operate at an elevation of 6000 feet
and is to deliver 3 PSI pressure. What pressure (standard air)
blower is required?
Pressure = 3 x 29.92 = 3.75 or 3 3/4 PSI
23.98
If it is desired to determine what pressure a 3 PSI (standard
air) blower will deliver at 6000 feet –
Pressure = 3 x 23.98 = 2.4 or about 2 1/2 PSI
29.92
When a blower is to operate at a high altitude it is frequently
specified that the blower be capable of handling a given
volume of “standard air”. It is then necessary to determine
the equivalent volume of air at the higher altitude.
Example – A blower is to operate 6000 feet altitude and is to
handle 1000 CFM of standard air. What is the CFM of air the
blower must handle at 6000 feet altitude?
Let: V1 = V olume of standar d air (1000 CFM)
V2 = Volume of thinner air
Hg1 = Barometric pressure sea level (29.92)
Hg2 = Barometric pressure 6000’ (23.98)
V2 = V1 x Hg1 = 1000 x 29.92 = 1248 CFM
Hg2 23.98
The pressure changes as the square of the
speed ratio.
Example – A blower is operating at a speed of 3500 RPM and
delivering air at 5.0 PSI pressure. If the speed is reduced to
3000 RPM, what is the new pressure?
P1 = Original Pressure (5 PSI)
P2 = New Pressure
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
P2 = P1 ( RPM2 )2 = 5 x ( 3000 )2 = 5 x .735 = 3.68 PSI
RPM1 3500
51 AE99
The Air Density varies in inverse proportion to the
absolute temperature.
Example – A blower is to handle 200O F air at 3 PSI pressure.
What pressure (standard air) blower is required?
Let: P1 = Pressure hot air (3 PSI)
P2 = Pressure standard air
AT1 = Absolute temperature hot air (200+460=660O F)
AT2 = Absolute temperature standard air (68+460=528O F)
P2 = P1 x AT1 = 3 x 660 = 3.75 or 3 3/4 PSI
AT2528
A blower is capable of delivering 3 PSI pressure with
standard air. What pressure will it develop handling 200O F
inlet air?
P1 = P2 x AT2 = 3 x 528 = 2.4 or about 2 1/2 PSI
AT1660
Pressur e varies in direct proportion to the density .
Example – A 3 PSI (standard air) blower is to be used to
handle gas having a specific gravity of 0.5. What pressure
does the blower create when handling the gas?
Let: Pa = Air pressure (3 PSI)
Pg = Gas pressure
SG = Specific gravity of gas (0.5)
Pg = Pa x SG = 3 x .5 = 1.5 PSI
If we are required to handle a gas having a specific gravity of
0.5 at 1.5 PSI pressure, we can determine the standard air
pressure blower as follows:
Let: Pa = Pg = 1.5 = 3 PSI
SG .5
Horsepower
The horsepower changes as the cube of the speed
ratio.
Example – A blower is operating at a speed of 3500 RPM and
requiring 50 horsepower. If the speed is reduced to 3000
RPM, what is the new required horsepower?
HP1 = Original Horsepower (50)
HP2 = New Horsepower
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
HP2 = HP1 x ( RPM2 )3 = 50 x ( 3000 )3 =
50 x .630 = 31.5 horsepower
RPM1 3500
Horsepower vs. Specific Gravity & Ratio of Density.
The horsepower varies in direct proportion to the specific
gravity (ratio of density of gas to density of air).
Example – A standar d air blower r equires a 10 HP motor.
What horsepower is required when this blower is to handle a
gas whose specific gravity is 0.5?
HP = 10 x 0.5 = 5 horsepower
It is possible that several of the above modifications may be
required on one installation. Therefore, it may be necessary
to use various combinations of these formulae.
AMETEK Aerospace
SENSORS/MONITORING SYSTEMS
www.ametek.com/aerospace
50 Fordham Road • Wilmington, MA 01887 U.S.A.
T el: 978-988-4101 • Fax: 978-988-4944
Sensors and interconnects for engines, airframes, launch vehicles and satellites, including fuel
flow, temperature, speed, pressure and liquid level. Monitoring systems, including vibration.
Digital bus adapters.
A VIONICS • www.ametek.com/aerospace
900 Clymer Avenue • Sellersville, PA 18960 U.S.A.
T el: 215-257-6531 • Fax: 215-257-1888
Data acquisition and interface units for avionics systems. Engine indicating systems. RVSM
altimeters. Fuel/hydraulic/water quality measuring systems.
GUL TON-STA THAM Products • www.gultonstatham.com
1644 Whittier Avenue • Costa Mesa, CA 92627 U.S.A.
T el: 949-642-2400 • Fax: 949-642-9490
Pressure, proximity and position sensors for aircraft, engines, airborne and land-based launch
vehicles, satellites, and industrial applications angle of attack sensors and stall warning
computers. Mud density and smart recording transmitters for oil and gas drilling.
SERVICE OPERATIONS
Distribution and Warehousing Operationwww.ametek.com/aerospace
Wilmington Service Center • 50 Fordham Road • Wilmington, MA 01887 U.S.A.
Tel: Warehouse 978-988-4100, Service: 978-988-4729
Fax: Warehouse: 978-988-4720, Service: 978-988-4408
Distribution of aerospace and industrial instruments, sensors, and spare parts. Maintenance of
instruments manufactured by AMETEK Aerospace. FAA Repair Station No. A8PR-221J.
Seattle Support Center
www.ametek.com/aerospace
4560 150th Avenue NE • Redmond, WA 98052 U.S.A.
T el: 425-881-1172 • Fax: 425-881-7292
Maintenance of instruments manufactured by AMETEK Aerospace. FAA Repair Station No.
HU6R600N.
AMETEK Chemical Products
HA VEG • www.ametek.com/havegE-mail: haveg@ametek.com
900 Greenbank Road • Wilmington, DE 19808 U.S.A.
T el: 302-995-0400, 800-441-7777 • Fax: 302-995-0491
SIL TEMP®, UL TISIL®, HA VEGLAS™ high-thermal-resistance fabrics for welding blankets,
furnace curtains, and insulation. FLEXSIL® molten metal filters. Corrosion-resistant HAVEG®
tanks, towers, valves, and piping. Fluoropolymer tubing and Heat Exchangers of TEFLON*.
WESTCHESTER PLASTICS • www.ametek-westchesterplas.com
Green Acres Industrial Park • Nesquehoning, PA 18240 U.S.A
T el: 570-645-2191 • Fax: 570-645-8564
Custom color compounding of elastomers, blends, reactive modifiers and other thermoplastic
resins. Small scale pilot runs through commercial production runs. Custom color matching
services.
AMETEK Dixson
DIXSON • www.ametekdixson.com
287 27 Road • Grand Junction, CO 81503 U.S.A.
T el: 888-302-0639, 970-242-8863 • Fax: 970-245-6267
OEM instrumentation and data collection units for the heavy duty vehicular market. Industrial
bargraph panel meters for commercial and nuclear applications. Process controls and
controllers for the fast-food preparation industry .
NATIONAL CONTROLS CORP.
(NCC) • www.nationalcontrols.com
1725 Western Drive • West Chicago, IL 60185 U.S.A.
T el: 630-231-5900, 800-323-2593 • Fax: 630-231-1377
Time delay relays, temperature monitors and controls, solid state relays and voltage monitors,
liquid level controls, and dust collectors/controls for the food industry , refrigeration, HVAC, test
chambers, and other industrial applications.
PANALARM • www. panalarm.com
1725 Western Drive • West Chicago, IL 60185 U.S.A.
T el: 847-675-2500 • Fax: 847-675-3011
Process monitoring annunciators, control room graphic displays, and high-speed event
recorders for petrochemical refineries, electrical generation and distribution, airport and train
event monitoring, water and wastewater treatment plants.
AMETEK Corporate Office
www.ametek.com
Station Square • Paoli, PA 19301 U.S.A.
T el: 610-647-2121, 800-473-1286 • Fax: 610-296-3412
AMETEK Global Operations
AMETEK elektromotory s.r.o.
ul. Beloveska 318 • Nachod 54701 Czech Republic
T el: 420-441-23877 • Fax: 420-441-23111
Shaded pole induction motors for heating and ventilation, thru-flow and bypass vacuum cleaner
motors, and universal series drive motors.
AMETEK GmbH
Weilimdorfer Str . 47 • D-70825 Korntal-Munchingen Germany
T el: +49-711-838-7876 • Fax: +49-711-838-7862
Sales for Electromechanical Group—Europe.
AMETEK Italia S.r.l.
CIARAMELLA • www.ametek.it
Via De Barzi • Robecco Sul Naviglio 20087 Italy
T el: +39-02-946931 • Fax: +39-02-94970518
Universal series drive motors for outdoor power equipment, small household appliances, floor
care and personal care products, and special applications.
V ACUUM Products • www.ametek.it
Via De Gasperi 18/A • Ripalta Cremasca 26010 Italy
T el: +39-0373-2101 • Fax: +39-0373-268200
Thru-flow and bypass vacuum motors for household, commercial, industrial canister , and upright
vacuum cleaners.
AMETEK Lamb Electric
www.ameteklamb.com
627 Lake Street • Kent, OH 44240 U.S.A.
T el: 330-673-3451 • Fax: 330-673-8994
Motors and motor-blower systems for industrial, commercial, and household vacuum cleaners,
ACUSTEK® motors, related floor-care equipment, and other applications such as paint sprayers,
material transport, spas, and outdoor power equipment, requiring a vacuum, pressure, or drive
source.
AMETEK Motors Shanghai Co. Ltd.
#1 AMETEK Road • Jiu Ting Economic Development Zone, Shanghai 201615 China
T el: 86-21-5763-2408 • Fax: 86-21-5763-2411
Fractional horsepower electric motors and blowers for Asian and
worldwide markets.
AMETEK Power and Industrial Products
www .ametek.com/power • E-mail: power.industrial@ametek.com
50 Fordham Road • Wilmington, MA 01887 U.S.A.
T el: 978-988-4101 • Fax: 978-988-4179
T emperature, pressure, speed and flame sensors and interconnects for land, marine, and utility
gas turbines and industrial boilers and burners. Gulton-Statham pressure, mud density , and
smart recording transmitters for oil and gas drilling.
AMETEK Precision Instruments Europe GmbH
Rudolf-Diesel-Strasse 16 • D-40670 Meerbusch Germany
T el: +49-2159-9136-0 • Fax: +49-2159-9136-39
Sales for Electronic Instruments Group—Europe and for AMETEK Rotron
T echnical Motor Division—Europe.
AMETEK Precision Instruments France SARL
3 Avenue des Coudriers, Z.A. de l’Observatoire • Montigny Le Bretonneux 78180 France
T el: 33 1 30 64 89 70 • Fax: 33 1 30 64 89 79
Sales for Electronic Instruments Group—France and for AMETEK Rotron
T echnical Motor Division—France.
AMETEK Precision Instruments (UK) Ltd.
www.ametek.co.ukE-mail: sales@ametek.co.uk
2 Queens Drive, Kings Norton Business Centre • Kings Norton, Birmingham B30 3HH England
T el: 44-121-246-2260 • Fax: 44-121-246-2270
Sales for Electronic Instruments Group—United Kingdom and Ireland.
Sales for Panalarm annunciator products—Europe, Middle East, Africa,
Pakistan and India. Sales for Thermox products—United Kingdom and Ireland.
52
AMETEK Process & Analytical Instruments
PROCESS INSTRUMENTS • www.ametekpi.com
455 Corporate Blvd. • Newark, DE 19702 U.S.A.
T el: 302-456-4400, 800-222-6789 • Fax: 302-456-4444
Continuous on-line photometric and trace moisture analyzers used for advanced process control,
emissions monitoring, and product quality improvement. Markets include chemical
manufacturing, semiconductor, and special packaging.
THERMOX Business Unit • www.thermox.com
150 Freeport Road • Pittsburgh, PA 15238 U.S.A.
T el: 412-828-9040 • Fax: 412-826-0399
THERMOX® oxygen analyzers for flue gas and industrial gas applications, combustion analyzers
for measuring oxygen and combustibles in a single analyzer , CO monitors, and premix gas
analyzers.
WESTERN RESEARCH • www.ametekpi.com
8 Manning Close N.E. • Calgary, Alberta T2E7N5 Canada
T el: 403-235-8400 • Fax: 403-248-3550
Sulfur Recovery Unit process monitoring, control, and emissions analyzers to measure air
demand, SO2, H2S, NOx concentrations. Dewpoint monitors, tunable diode laser spectrometers,
and temperature monitors.
AMETEK Rotron
COMMERCIAL BRUSHLESS Products • www.ametektmd.com
627 Lake Street • Kent, OH 44240 U.S.A.
T el: 330-673-3452 • Fax: 330-678-8227
Brushless DC motors, WINDJAMMER® and MINIJAMMER® motor-blowers, and low-voltage
controllers for computers, business machines, medical devices, pumps and compressors,
industrial equipment, and such mass-transit vehicles as transit buses, rail cars, and
locomotives.
MIL-AERO Products • www.rotron.com
9 Hasbrouck Lane • Woodstock, NY 12498 U.S.A.
T el: 914-679-2401 • Fax: 914-679-7080
AC and brushless DC fans and blowers, heat exchanger and blower systems, fault detection
devices, and electronic power conversion devices for the military and aerospace markets.
Repair of products manufactured by AMETEK Rotron T echnical Motor Division. F AA Repair
Station No. AN1R014K.
INDUSTRIAL Products and BIOFIL TRA TION Products •
www.rotron.com
75 North Street • Saugerties, NY 12477 U.S.A.
T el: 914-246-3401 • Fax: 914-246-3802
Industrial Products: Regenerative air blowers for pressure and vacuum applications
up to 1800 SCFM and 10 PSIG servicing the Industrial, Environmental, Instrumentation, &
T elecommunication markets. T ypical applications include solution agitation & aeration, pneumatic
conveying, part hold-down and pick up, part blow off, gas & fume extraction, and process gas
handling. Biofiltration Products: Patented modular Biofiltration systems that remove noxious
odors and vapors from gaseous exhaust and air supply systems in commercial, municipal
wastewater , and industrial applications.
AMETEK Sensor Technology
P ATRIOT Products • www .patriotsensors.com
1080 N. Crooks Road • Clawson, MI 48017-1097 U.S.A.
T el: 248-435-0700 • Fax: 248-435-8120
Position sensors including rotary cam limit switches, programmable limit switches, linear
position sensors and rotary encoders; programmable controller bus cards including ultra-high
speed programmable limit switches and electronic encoders for linear and rotary inputs;
stamping press automation including shut height monitors; specialty products including cable and
hose carrier systems. Point level sensor products including conductivity sensors, conductivity
relays and magnetic probes; continuous level sensors including magnetostrictive probes for tank
gauging and leak monitoring.
DREXELBROOK Products • www.drexelbrook.com
205 Kieth Valley Road • Horsham, PA 19044 U.S.A.
T el: 215 674-1234• Fax: 215 674-2731
RF and ultrasonic level sensors in a broad range of packages for chemical, petrochemical, water ,
waste water , food, beverage and pharmaceutical monitoring; continuous and point level sensors;
IS and EX applications; line powered, low voltage, 4-20mA loop powered, HART and other
networked outputs. Clarifier and sludge blanket sensor systems for wastewater applications.
Level sensors for aerospace applications.
AMETEK Specialty Metal Products
CLAD METALS and METAL POWDERS •
www.ametekmetals.com
Route 519 • Eighty Four , P A 15330 U.S.A.
T el: 724-225-8400 • Fax: 724-225-6622
Stainless steel and nickel clad alloys used in high-quality cookware, sterilizers and chemical
processing equipment. Stainless steel, cobalt, and nickel alloy metal powders for powder
metallurgy , hardfacing, metal injection molding, polymer filtration, and plastic compounding.
AMETEK Specialty Metal Products
MET AL STRIP and SPECIALTY WIRE • www.ametekmetals.com
21 Toelles Road • Wallingford, CT 06492 U.S.A.
T el: 203-265-6731, 800-233-2266 • Fax: 203-265-6407
Wrought powder metallurgy for engineered custom metal strip and wire including SEAL VAR®
iron-nickel cobalt, custom shaped wire, metal matrix composites including HIVOL™ silicon
carbide aluminum, and fully dense components (FDC). FDC include vacuum sputtering targets for
thin film deposits through the ISOFORM™ technology using the Pneumatic Isostatic Forging
process. Product applications include satellites, land-and sea-based radar systems, computers,
chip mounting, heat sinks, and reflective coatings.
AMETEK Shanghai (SPL)
Room 16B5, Harvest Bldg. • #585 Long Hua Xi Road, Shanghai 200232 China
T el: 86-21-6428-4067, 86-21-6469-8814 • Fax: 86-21-6487-5329
Representative Office of AMETEK Singapore Pte. Ltd.
AMETEK Singapore Pte. Ltd.
10 Ang Mo Kio Street 65 • #05-12 TECHPOINT 569059 Singapore
T el: 65-484-2388 • Fax: 65-481-6588E-mail: aspl@ametek.com.sg
Sales for all AMETEK products—Pacific Rim.
AMETEK Test and Calibration Instruments
CHATILLON®
Force Measurement Products
www.chatillon.com
8600 Somerset Drive • Largo, FL 33773 U.S.A.
T el: 727-536-7831, 800-527-9999 • Fax: 727-539-6882
Force gauges, universal testing machines, and material test instruments,
automated testing software, gripping fixtures and accessories.
AMETEK Denmark A/S • www.ametek.com/tci
Gydevang 32-34, PO Box 30 • DK-3450 Allerod Denmark
T el: 45-4816-8000 • Fax: 45-4816-8080
JOFRA temperature and pressure calibrators and FRODE PEDERSEN sensors
(also markets other AMETEK instrument products throughout Europe).
LLOYD INSTRUMENTS™ Material T esting Products
www.lloyd-instruments.co.uk
12 Barnes Wallis Road, Segensworth East • Fareham, Hampshire PO15 5TT England
T el: 44-1489-574221 • Fax: 44-1489-885118
Materials testing machines, force gauges and test stands, melt flow indexers, friction testers, melt
viscometer , density column, plastic film impact testers, and heat distortion equipment (HDT/VICA T).
MANSFIELD & GREEN Products • www.ametek.com/tci
8600 Somerset Drive • Largo, FL 33773 U.S.A.
T el: 727-536-7831, 800-527-9999 • Fax: 727-539-6882
Electronic tachometers and stroboscopes, force and torque gauges, deadweight testers, pressure
calibrators, diaphragm seals, and air/noise monitoring instruments.
AMETEK U.S. Gauge
U.S. GAUGE Products • www.ametekusg.com
900 Clymer Ave. • Sellersville, PA 18960 U.S.A.
T el: 215-257-6531 • Fax: 215-257-3058
Pressure and temperature gauges for industrial use, process industries, and OEM applications.
Pressure gauges for compressed gas, welding, and medical applications. Solid front pressure
gauges and diaphragm seals for chemical, petrochemical, and other process industries. Hunter
Spring NEG’A TOR® and SPIR’ATOR® constant force springs and spring powered retracting reels.
PMT Products • www.ametekusg.com
820 Pennsylvania Blvd. • Feasterville, PA 19053 U.S.A.
T el: 215-355-6900, 888-625-5895 • Fax: 215-355-2937
Pressure transducers and transmitters for industrial markets, pressure gauges, switches,
transmitters, displays and cylinder sales for UHP semiconductor manufacturing markets, level
measurement systems, pneumatic controllers, and gas energy content (BTU) meters.
AMEKAI Taiwan Co., Ltd.
2-Floor , No. 214 Alley 1 • Lane 138, Chang-An Street • Pan-Chiao, T aipei T aiwan
T el: 886-2-2954-1765 • Fax: 886-2-2951-3443
Joint venture with T aiwanese partner . General industrial use mechanical
pressure gauges for Asian and worldwide markets.
AMEKAI Meters (XIAMEN) Co., Ltd.
1-2 Floors, Chuang Xin Bldg., Torch High Technology Industrial Zone
Innovate City, Xiamen, Fujian 361006 China
T el: 86-592-603-0565 • Fax: 86-592-603-0570
Joint venture with Chinese partner . General industrial use mechanical
pressure gauges for Asian and worldwide markets.
53
54
Contact Information
627 Lake Street
Kent, OH 44240
Main Tel: (330) 673-3452
Fax: (330) 678-8227
www.ametektmd.com
e-mail: info@ametektmd.com
AMETEK GmbH
Weilimorder Str. 47
70825 Korntal-Munchingen
Germany
Main Tel: 49-711-838-7876
Fax: 49-711-838-7862
Distributors
Allied Electronics
1-800-433-5700
www.allied.avnet.com
Grainger
1-800-323-0620
www.grainger.com
ROTRON
Technical Products
AMETEK, Inc.
AMETEK is a leading global manufacturer of electrical and electromechanical products for niche markets.
Listed on the New York Stock Exchange (AME) since 1930, AMETEK’s annual sales are approaching $1
billion. Operations are in North America, Europe, and Asia, with about one-third of sales to markets outside
the United States. AMETEK is serving its customers with investments in new products, global and market
expansion, strategic acquisitions, and operational excellence. The Company’s operating groups are
Electronic Instruments and Electromechanical.
Rotron
The Electromechanical Group (EMG) is one of the world’s largest producers of high-speed electric motor
products for original equipment manufacturers (OEMs). In business since 1915, EMG is using its core
competencies to enhance its worldwide presence. A business unit of AMETEK EMG, Rotron has facilities
in California, New York, North Carolina, and Ohio. Rotron serves the military, aerospace, medical,
transportation, office equipment, industrial, and environmental markets worldwide. Rotron supports its
customers with more than 650 employees that are organized in three business segments:
• Technical Products
• Military & Aerospace Products
• Industrial Products
Technical Products
Rotron’s standard product lines of brushless DC motors, blowers, and controllers offer a wide range of
application demands. Brushless DC motors and blowers are an ideal choice for such varied applications
as medical instruments, robotics, pumps, compressors, office equipment, fans, machine tools, tape drives,
or any other precise rotary motion/air delivery applications. If there is a need for a product with unique
performance, mounting environment, or agency requirements, Rotron can supply the solution.
ROTRON
Technical Products
627 Lake Street, Kent, Ohio 44240
Telephone: 330-673-3452 • Fax: 330-678-8227 • www.ametektmd.com
©2000, by AMETEK, Inc.
5M200N (140044)