03 | Keysight | U8000 Series Single Output DC Power Supplies - Data Sheet
Great Features and Solid
Performance —
Within Budget
Differentiated features typically found
only in programmable power supplies
The U8000 Series offers fully
integrated over voltage protection
(OVP) and over current protection
(OCP) to prevent damage to the
device-under-test (DUT). Using the
capability to save and recall three
memory states, you can minimize
errors and reduce set-up time. The
U8000 Series also provides security
features such as keypad lock to
prevent measurement errors due
to accidental front panel usage.
When the keypad lock is activated,
the knob and all the buttons on the
front panel are disabled except the
keypad lock button. The physical lock
mechanism found at the rear panel
of the power supply provides secure
instrument storage. The LCD display
with backlight on/off options enables
brighter display for data viewing (see
Figure 2).
Solid, reliable performance in its
class
The U8000 Series provides excellent
load and line regulation (Constant
Voltage, CV: < 0.01% +2 mV; Constant
Current, CC: < 0.02% +2 mA) to
ensure stable output even when the
load changes. With the fast 50 sec
transient response, test times and
manufacturing cost are significantly
reduced. The U8000 Series comes with
low output noise of 1 mVrms, 3 mArms
from 20 Hz to 20 MHz, providing clean
output and minimizing the interference
in the DUT.
Figure 2. Backlight on/off options for LCD display
Backlight ON Backlight OFF
Get That Something Extra:
Safety and Security
The U8000 Series has been stringently
tested according to various industrial
safety standards: CSA (for US and
CA regulatory requirements), C-tick
(Australia), and CE (Europe). The
U8000 Series is fully integrated with
OVP and OCP in order to prevent
damage to the DUT. The security
features offered in the U8000 Series
prevent measurement errors and also
ensure safety storage of the power
supply. Security features such as
keypad locking capability preclude
accidental front panel usage while
the physical lock mechanism provides
secure instrument storage.
Front Panel Operation
An easy-to-use rotary knob and
self-guiding keypads allow you to set
the output at your desired resolution
without any effort. Also, both voltage
and current levels can be set to a
maximum resolution of 10 mV/10 mA
from the front panel. In addition, you
can save and recall for up to three
operating states that are stored in the
internal non-volatile memory.
Easy-to-use control functions:
– Enabling or disabling OVP and OCP
– Setting the OVP and OCP trip levels
– Clearing OVP and OCP conditions
– Setting and displaying the voltage
and current limit values
– Operating state storage/recall
– Resetting the power supply to
power-on state
– Calibrating the power supply
– Enabling or disabling the output
Compliant to several safety
standards—CSA, C-tick, CE
Physical lock
mechanism