DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE
DESIGNATED.
Outer jacket color will be white (designated by a “-9" appended
to the part number, e.g. 0024A0311-9) unless otherwise
specied.
Designate outer jacket color with a dash number in accordance
with MIL-STD-681. Other codes and sufxes may be added to
the part number, as necessary, to capture any additional
requirements imposed by the purchase order.
Users should evaluate the suitability of this product for their application. Specications are subject to change without notice. Tyco Electronics
Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specication,
without notication to Buyer.
Page 1 of 1 Rayfoam, Thermorad, Cheminax, Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
© 2012-2013 Tyco Electronics Corporation, All rights reserved.
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
Raychem Wire & Cable THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS
REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE
ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
DIELECTRICS
Rayfoam L
Colors - White/Tan
CONDUCTORS
AWG 24, 19 Strands of
AWG 36, Tin-Coated
Copper
.127
.157
(nominal)
.166
(maximum)
.0235
SPECIFICATION CONTROL DRAWING 0024A0311
CHEMINAX 100 OHM, AWG 24, 19 STRANDS OF AWG 36, TWINAXIAL CABLE Date 2-21-13
Revision G
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS
.055
SHIELD
AWG 38,
Tin-Coated Copper
JACKET
Thermorad S
CHARACTERISTIC IMPEDANCE 100 ± 10 ohms, Method C at 1 MHz
MUTUAL CAPACITANCE 13.5 pF/ft. (nominal)
VELOCITY OF PROPAGATION 79% (nominal)
ADDITIONAL REQUIREMENTS
ELECTRICAL
CONDUCTOR RESISTANCE 25.7 ohms/1000 ft. (nominal)
INSULATION RESISTANCE 10,000 megohms (minimum)
for 1000 ft.
JACKET FLAWS
SPARK TEST
IMPULSE TEST
1.0 kV (rms)
6.0 kV (peak)
VOLTAGE WITHSTAND (DIELECTRIC) 1000 volts (rms) (minimum)
ENVIRONMENTAL
FLAMMABILITY Method C
HEAT SHOCK 225°C
LOW TEMPERATURE-COLD BEND -55°C/1.50 inch mandrel
VOLTAGE WITHSTAND
(Post Environmental)
1000 volts (rms),1 minute
PHYSICAL
INSULATION (DIELECTRIC)
(Prior to Cabling)
ELONGATION
TENSILE STRENGTH
50% (minimum)
800 lbf/in2 (minimum)
JACKET
ELONGATION
TENSILE STRENGTH
100% (minimum)
2000 lbf/in2 (minimum)
JACKET THICKNESS .015 inch (nominal)
SHIELD COVERAGE 90% (minimum)
WEIGHT 16.0 lbs/1000 ft. (nominal)
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
0024A0311-0