SPECIFICATION CONTROL DRAWING TITLE EPD6062 Date ONE CONDUCTOR CABLE, SPIRALLY SHIELDED, JACKETED Revision C 7-29-04 This specification sheet forms a part of the latest issue of Raychem Specification 55A. SHIELD - SPIRAL, TIN-COATED COPPER JACKET - COMPONENT WIRE - EPD6062-AWG-CO1 RADIATION-CROSSLINKED, MODIFIED ETFE CABLE CONSTRUCTION DETAILS PART NUMBER 1/ CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) MINIMUM JACKET THICKNESS (inch) 16 14 12 10 38 38 38 38 .007 .007 .007 .013 OUTSIDE DIAMETER (inch) NOMINAL EPD6062-16-* EPD6062-14-* EPD6062-12-* EPD6062-10-* .104 .118 .140 .177 MAXIMUM .111 .123 .147 .185 MAXIMUM WEIGHT (lb/1000 ft) 15.42 21.30 30.20 47.29 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 3C for 7 hours BLOCKING: 200 3C for 6 hours DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz FLAMMABILITY: Procedure 1, 3 seconds (maximum); 3 in. (maximum); no flaming of facial tissue JACKET COLOR: White preferred JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1000 volts (rms) Impulse Dielectric Test, 6.0 kV (peak) LIFE CYCLE: 200 3C for 168 hours LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours SHIELD COVERAGE: 90% (minimum) VOLTAGE WITHSTAND TEST (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "*" in the part numbers above shall be replaced by a color code designator with a dash separating the component wire color from the jacket color. 1/ Example: AWG 16, white component wire; white jacket: EPD6062-16-9-9 NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. R Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297