AC AXIAL FANS
Tel: 425-222-5900 800-453-4569www.mechatronics.com E-mail: Sales@Mechatronics.com Fax: 425-222-5155 Cooling Simplified
UF25GC series
0 100 200
AIR FLOW (CFM)
STATIC PRESSURE - IN. OF WATER
300 400 500 600 700 800 900
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0.1
1
2
3
LEAD WIRE TYPE
3.5 ±0.02
(89 ±0.5)
0.10
(2.5)
ø10.0 ±0.03
(ø254 )
+1.0
– 0.5
ø0.18 ±0.01
(ø4.6 ±0.2)
ø9.6 9
(ø246)
ø8.6 6
(ø220)
t=0.5
TERMINAL TYPE
0.12
(3)
0.31
(8)
(254 dia. x 89 mm)
10.0 dia. x 3.5 inches
Operating voltage: 115 or 230 VAC
Construction: aluminum die cast frame;
UL94V-0 PBT impeller
Bearing option: ball bearing
Motor: permanent split capacitor
Air Flow: exhaust over struts
Connection: terminal or 22 AWG lead wires
Protection: thermal
Options: dual voltage 115/130VAC,
IP55; IP55 + salt fog,
tachometer output
Model No.
Rated
Voltage
V
Freq.
HZ
Input
Power
W
Rated
Cur.
A
Locked
Cur.
A
Speed
RPM
Air Volume M ax . S ta ti c
Pressure (H20)
Sound
Noise
dbA
Weight
kg
Curve
M³/Min. CFM MM INCH
UF25GC12-_ _H 115 60 33 0.29 0.51 1,650 15.5 550 10 0.40 55 1.90 1
UF25GC23-_ _H 230 60 33 0.14 0.25 1,650 15.5 550 10 0.40 55 1.90 1
UF25GCA12-_ _H 115 60 75 0.66 0.70 2,600 19.3 680 9.4 0.37 62 1.90 2
UF25GCA23-_ _H 230 60 75 0.35 0.36 2,600 19.3 680 9.4 0.37 62 1.90 2
UF25GCB12-_ _H 115 60 96 0.88 1.16 3200 23.0 812 20.7 0.82 65 2.30 3
UF25GCB23-_ _H 230 60 98 0.45 0.60 3200 23.0 812 20.7 0.82 65 2.30 3
11.30.15