SPECIFICATION
60W AC-DC High Reliability Slim Wall-mounted Adaptor SG A 60 E s er i e s
SAFETY STANDARDS TUV EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
LIFE
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 9V7.5V 12V 15V 18V 24V 48V
SGA60E05 SGA60E09SGA60E07 SGA60E12 SGA60E15 SGA60E18 SGA60E24 SGA60E48
SGA60E05-P1J
SGA60E09-P1JSGA60E07-P1J
SGA60E12-P1J
SGA60E15-P1J
SGA60E18-P1J
SGA60E24-P1J
SGA60E48-P1J
6A 5.5A6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 5.5A0 ~ 6A
0 ~ 5A
0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
80mVp-p 80mVp-p80mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0%±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
90 ~ 264VAC
47 ~ 63Hz
1.5A / 115VAC 0.75A / 230VAC
Cold start 40A / 115VAC 80A / 230VAC
0.25mA / 240VAC
3 years : 100% load 40℃, 12hours / day
400Khrs min. MIL-HDBK-217F(25℃)
-20 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03% / ℃ (0 ~ 40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
93.5*35*51.5mm (L*W*H)
250g ; 60pcs / 17kg / CARTON
CONNECTOR
PLUG
CABLE
30W 50W45W 60W 60W 60W 60W 60W
0 ~ 1.25A
OVERLOAD
OVER VOLTAGE
110 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
2500ms, 50ms, 10ms/230VAC 2500ms, 50ms, 10ms/115VAC at full load
83.5% 86.5%85% 87.5% 87% 88% 88% 89.5%
See page 4~5 ; Other type available by customer requested
See page 4~5; Other type available by customer requested
℃
http://www.meanwell.com)
※: https://www.meanwell.com/serviceDisclaimer.aspx
SAFETY &
EMC
(Note. 8)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32)
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11
EN55032(CISPR32)
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 3, 1KV/L-N
Level 1, 1A/m
Level 2, 3V
Level 2, 1KV
RF field susceptibility
Magnetic field immunity
Voltage dips , interruption
File Name:SGA60E-SPEC 2020-10-30