VDE High electrical & mechanical noise immunity relay 20 .787 FEATURES 10 .394 * High electrical noise immunity * High switching capacity in a compact package * High sensitivity: 200 mW (1a), 400 mW (1c) * High surge voltage: 8,000 V between contacts and coil * UL, CSA, VDE, TUV, SEMKO approved * Class B coil insulation type available 15.6 .614 mm inch JQ JQ RELAYS About Cd-free contacts We have introduced cadmium-free type products to reduce environmentally hazardous substances. Please replace parts that contain cadmium with Cd-free products. Evaluate them with your actual application before use because the life of a relay depends on the contact material and load. SPECIFICATIONS Contact Standard type Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material 100 m 1a Nominal switching capacity 1c N.O. N.C. 1a Rating (resistive) Max. switching power High capacity type 1 Form A, 1 Form C 1c N.O. N.C. Max. switching voltage Max. switching current Min. switching capacity#1 Expected mechanical life (at 180 cpm)(min. operations) AgSnO2 type 5 A 125 V AC, 2 A 250 V AC, 5 A 30 V DC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC 5 A 125 V AC, 2 A 250 V AC, 3 A 30 V AC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC 2 A 125 V AC, 1 A 250 V AC, 1 A 30 V DC 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC 625 VA, 150 W 1,250 VA, 150 W 625 VA, 90 W 1,250 V AC, 150 W 250 VA, 30 W 500 V AC, 30 W 250 V AC, 110 V DC (0.3A) N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A 100 mA, 5 V DC 107 Expected electrical life (min. operations) Type 1a Standard type N.O. 1c N.C. 1a High capacity type N.O. 1c N.C. Switching capacity 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 5 A 125 V AC 2 A 250 V AC 3 A 30 V DC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC No. of operations 5104 2105 2105 105 5104 2105 105 2105 2105 105 5104 5104 105 5104 5104 105 2105 2105 105 1a: 200 mW 1c: 400 mW Coil (at 20C 68F) Nominal operating power #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. ds_61B03_en_jq: 100811D 1 JQ Characteristics Max. operating speed Initial insulation resistance*1 Initial breakdown voltage*2 20 cpm Min. 1,000 M at 500 V DC 1a: 1,000 Vrms for 1 min. 1c: 750 Vrms for 1 min. 4,000 Vrms for 1 min. 8,000 V Max. 20 ms Max. 10 ms Max. 45C Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm -40C to +85C -40F to +185F 5 to 85% R.H. Approx. 7 g .25 oz Between open contacts Between contacts and coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage)(without diode) Temperature rise*5 Functional*6 Shock resistance Destructive*7 Functional*8 Vibration resistance Destructive Ambient temp.*10 Conditions for operation, transport and storage*9 (Not freezing and condensing at low temperature) Humidity Unit weight Remarks * *1 *2 *3 *4 *5 Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section Detection current: 10 mA Wave is standard shock voltage of 1.2 50s according to JEC-212-1981 Excluding contact bounce time Measured conditions Standard type Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70C 158F High capacity type Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70C 158F *6 Half-wave pulse of sine wave: 11ms; detection time: 10s *7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10s *9 Refer to "6. Usage, Storage and Transport Conditions" in AMBIENT ENVIRONMENT section in Relay Technical Information. *10When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range. TYPICAL APPLICATIONS * Air conditioners * Refrigerators * Microwave ovens * Heaters ORDERING INFORMATION Ex. JQ 1a P B 12 V F Contact arrangement Contact capacity Coil insulation class Coil voltage (DC) Contact material 1a: 1 Form A 1: 1 Form C Nil: Standard P: High capacity Nil: Class E coil insulation B: Class B coil insulation 5, 6, 9, 12, 18, 24, 48* V F: AgSnO2 type UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type 2 ds_61B03_en_jq: 100811D JQ TYPES AND COIL DATA at 20C 68F Standard type High capacity type High capacity type 1 Form C Standard type 1 Form A Part No. Nominal voltage, V DC JQ1a-5V-F JQ1a-6V-F JQ1a-9V-F JQ1a-12V-F JQ1a-18V-F JQ1a-24V-F JQ1aP-5V-F JQ1aP-6V-F JQ1aP-9V-F JQ1aP-12V-F JQ1aP-18V-F JQ1aP-24V-F JQ1-5V-F JQ1-6V-F JQ1-9V-F JQ1-12V-F JQ1-18V-F JQ1-24V-F JQ1-48V-F JQ1P-5V-F JQ1P-6V-F JQ1P-9V-F JQ1P-12V-F JQ1P-18V-F JQ1P-24V-F JQ1P-48V-F 5 6 9 12 18 24 5 6 9 12 18 24 5 6 9 12 18 24 48 5 6 9 12 18 24 48 Pick-up voltage, V DC (min.) 3.75 4.5 6.75 9 13.5 18 4 4.8 7.2 9.6 14.4 19.2 3.75 4.5 6.75 9 13.5 18 36 4 4.8 7.2 9.6 14.4 19.2 38.4 Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 0.25 0.3 0.45 0.6 0.9 1.2 2.4 Nominal operating current, mA 40 33.3 22.2 16.7 11.1 8.3 40 33.3 22.2 16.7 11.1 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 Nominal operating power, mW 125 180 405 720 1,620 2,880 125 180 405 720 1,620 2,880 62.5 90 202.5 360 810 1,440 5,760 62.5 90 202.5 360 810 1,440 5,760 200 200 400 400 DIMENSIONS (mm inch) CAD Data Coil resistance, (10%) Max. allowable voltage, V DC 180% of nominal voltage (at 20C 68F) 130% of nominal voltage (at 85C 185F) 150% of nominal voltage (at 20C 68F) 110% of nominal voltage (at 85C 185F) CAD Data Data from our Web site. Download CAD 1 Form A 10 .394 1 Form A 20 .787 Schematic (Bottom view) 1 Form C COM N.O. Coil 15.6 .614 COM N.O. Coil N.C. 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 10.16 .400 0.3 .012 7.62 .300 0.3 .012 7.62 .300 0.8 .031 1 Form A 1 Form C 10 .394 20 .787 10.16 .400 15.6 .614 4.2 .165 0.5 dia. .020 dia. 4-1.3 dia. 4-.051 dia. 10.16 .400 7.62 .300 5-1.3 dia. 5-.051 dia. 7.62 .300 Tolerance: 0.1 .004 10.16 .400 0.3 .012 Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .118 inch Min. 5mm .118 inch ds_61B03_en_jq: 100811D 7.62 .300 7.62 .300 0.4 .016 7.62 .300 PC board pattern (Bottom view) 1FormC 5.08 .200 2.54 .100 0.3 .012 0.3 .012 7.62 .300 0.8 .031 General tolerance 0.2 .008 0.3 .012 0.4 .016 3 JQ REFERENCE DATA Max. switching capacity (1 Form A type) Max. switching capacity (1 Form C type) 100 Contact current, A Contact current, A 100 AC resistive load (High capacity type) 10 5 10 5 3 2 AC resistive load 1 (High capacity type) N.C. side AC resistive load (Standard type) N.C. side 1 AC resistive load (Standard type) 10 AC resistive load (High capacity type) N.O. side AC resistive load (Standard type) N.O. side 100 277 10 1,000 100 277 1,000 Contact voltage, V Contact voltage, V Standard type 1-(1). Operate & release time (1 Form A type) 1-(2). Operate & release time (1 Form C type) 2. Life curve Tested sample: JQ1a-12V-F, 25 pcs. Tested sample: JQ1-24V-F, 25 pcs. Ambient temperature: room temperature 6 Operate time 4 Max. Max. Min. Min. 2 Release time 0 80 100 8 125V AC resistive load Life, x104 8 Operate & release time, ms Operate & release time, ms 100 6 Operate time 4 250V AC resistive load Max. Max. Min. Min. 2 Release time 120 0 150 80 100 Coil applied voltage, %V 120 1 150 Coil applied voltage, %V 0 1 2 3 4 5 Contact current, A 3-(1). Coil temperature rise (1 Form A type) 3-(2). Coil temperature rise (1 Form C type) Contact carrying current: 3 A, 5 A Measured portion: Inside the coil Contact carrying current: 3 A, 5 A Measured portion: Inside the coil 70 50 60 40 Temperature rise, C Temperature rise, C 10 5 A at 70C 5 A at 85C 30 20 3 A at 70C 5 A at 70C 50 3 A at 70C 40 5 A at 85C 30 3 A at 85C 20 3 A at 85C 10 10 0 0 100 110 120 130 140 150 160 170 180 190 100 110 Coil applied voltage, %V 120 130 140 150 160 Coil applied voltage, %V 4-(1). Ambient temperature characteristics (1 Form A type) 4-(2). Ambient temperature characteristics (1 Form C type) Tested sample: JQ1a-24V-F Contact carrying current: 3 A, 5 A Tested sample: JQ1-24V-F Contact carrying current: 3 A, 5 A 400 300 200 100 Coil applied voltage, %V Coil applied voltage, %V 400 300 20 30 40 50 60 70 80 Ambient temperature, C 4 100 0 200 90 0 20 30 40 50 60 70 80 Ambient temperature, C 90 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 3 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 5 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 3 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 5 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A) 7 Pick-up voltage ds_61B03_en_jq: 100811D JQ High capacity type 2. Life curve Tested sample: JQ1P-12V-F, 25 pcs. Ambient temperature: room temperature 6 Operate time 4 Max. Min. Max. Min. 2 80 100 8 6 Operate time 4 Release time 120 0 150 80 100 Coil applied voltage, %V 120 250V AC resistive load 1 150 Coil applied voltage, %V 0 2 4 6 8 10 Contact current, A 3-(1). Coil temperature rise (1 Form A type) 3-(2). Coil temperature rise (1 Form C type) Contact carrying current: 5 A, 10 A Measured portion: Inside the coil Contact carrying current: 5 A, 10 A Measured portion: Inside the coil 70 125V AC resistive load 10 Max. Max. Min. Min. 2 Release time 0 100 Life, x104 8 Operate & release time, ms 1-(2). Operate & release time (1 Form C type) Tested sample: JQ1aP-12V-F, 25 pcs. Operate & release time, ms 1-(1). Operate & release time (1 Form A type) 70 Temperature rise, C Temperature rise, C 10 A at 85C 60 10 A at 85C 50 10 A at 70C 40 5 A at 70C 30 60 10 A at 70C 50 5 A at 70C 40 5 A at 85C 30 5 A at 85C 20 20 10 10 0 100 120 140 160 0 180 100 110 120 130 140 150 160 Coil applied voltage, %V Coil applied voltage, %V 4-(1). Ambient temperature characteristics (1 Form A type) 4-(2). Ambient temperature characteristics (1 Form C type) Tested sample: JQ1aP-24V-F Contact carrying current: 5 A, 10 A Tested sample: JQ1P-24V-F Contact carrying current: 5 A, 10 A 400 Coil applied voltage, %V Coil applied voltage, %V 400 300 200 200 100 100 0 300 20 30 40 50 60 70 80 Ambient temperature, C ds_61B03_en_jq: 100811D 90 0 20 30 40 50 60 70 80 Ambient temperature, C 90 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 5 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 10 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 5 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 10 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 7 Pick-up voltage 5 JQ SAFETY STANDARDS Item Standard type (5A) 1 Form A Standard type (5A) 1 Form C High capacity type (10A) 1 Form A High capacity type (10A) 1 Form C UL/C-UL (Recognized) CSA (Certified) VDE (Certified) File No. Contact rating File No. Contact rating File No. Contact rating 5A 125V AC 5A 125V AC 5A 250V AC E43028 LR26550 40011435 5A 277V AC 5A 277V AC (cos =0.4) 5A 30V DC 5A 30V DC 0.3A 110V DC 0.3A 110V DC 1/10HP 125V 1/10HP 125V AC AC 1/6HP 277V AC 1/6HP 277V AC 5A 250V AC 5A 125V AC 5A 125V AC LR26550 40011435 (cos =0.4) E43028 5A 277V AC 5A 277V AC (N.O.) 5A 30V DC 5A 30V DC 3A 250V AC 0.3A 110V DC 0.3A 110V DC (cos =0.4) 1/10HP 125V 1/10HP 125V (N.C.) AC AC 1/6HP 277V AC 1/6HP 277V AC E43028 E43028 10A 250V AC 10A 125V AC LR26550 10A 125V AC 40011435 (cos =0.4) 8A 277V AC 8A 277V AC 5A 30V DC 5A 30V DC 0.3A 110V DC 0.3A 110V DC 1/6HP 125V AC 1/6HP 125V AC 1/6HP 277V AC 1/6HP 277V AC (N.O.) 10A 125V AC LR26550 10A 125V AC 40011435 10A 250V AC 8A 277V AC (cos =0.4) 8A 277V AC 5A 30V DC (N.C.) 5A 30V DC 0.3A 110V DC 3A 250V AC 0.3A 110V DC 1/6HP 125V AC 1/6HP 125V AC (cos =0.4) 1/6HP 277V AC 1/6HP 277V AC File No. TUV (Certified) Rating SEMKO (Certified) File No. Contact rating B 08 09 13461 252 5A 250V AC (cos =0.4) 5A 30V DC (0ms) B 08 09 13461 252 5A 250V AC (cos =0.4) 5A 30V DC (0ms) B 08 09 13461 252 10A 250V AC (cos =0.4) 5A 30V DC (0ms) B 08 09 13461 252 10A 250V AC (cos =0.4) 5A 30V DC (0ms) 817138 3(2)A 125V AC 2(1)A 250V AC 5A 30V DC 817138 3(2)A 125V AC 2(1)A 250V AC 5A 30V DC 817138 5(3)A 250V AC 5A 30V DC 817138 5(3)A 250V AC 5A 30V DC For Cautions for Use, see Relay Technical Information. 6 ds_61B03_en_jq: 100811D