PCB Power Relay
Power Relay with 110 VDC 5 A
Switching Capacity (Use 2 poles in
series with 3 mm contact gap)
2.8-mm contact gap (EN50091-1) satisfies the European
requirement of UPS (uninterrupted power supply).
Offers high insulation with insulation distance above 8 mm and
impulse withstand voltage of 10 kV between coil and contacts.
Standard model conforms to VDE standards.
Model Number Legend Application Examples
Home appliances
OA equipments
Industrial machinery
Ordering Information
Note. When ordering, add the rated coil voltage to the model number.
Example: G2RG-2A4 DC12
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
Ratings
Coil
Note 1. The rated current and coil resistance are for a coil temperature of 23°C
and have a tolerance of ±10%.
Note 2. The operating characteristics given in the above table are for a coil
temperature of 23°C.
Note 3. The maximum allowable voltage is the maximum possible value of the
voltage that can be applied to the relay coil.
Contacts
* This value was measured at a switching frequency of 120 operations/min.
Contacts in line 2 pole
Characteristics
Note. The above values are initial values (at an ambient temperature of 23°C.)
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Measured with a 500 VDC megohmmeter at the
same places as the dielectric strength.
RoHS Compliant
G2RG-@@@
———
123
1. Number of Poles
2: 2-pole
2. Contact Form
A: N.O. contact
DPST-NO (2a)
3. Enclosure rating
4: Fully sealed
Contact form Model Rated coil voltage Minimun
packing unit
DPST-NO
(2a) G2RG-2A4 12 VDC
24 VDC 100 pcs/tray
Item Rated
current
(mA)
Coil
resistance
(
Ω
)
Must-operate
voltage
(V)
Must-release
voltage
(V)
Maximum
voltage
(V)
Power
consumption
(mW)
Rated voltage % of rated voltage
12 VDC 66.6 180 80% max. 10% min. 140%
(at 23°C)
Approx.
800
24 VDC 33.3 720
Item Load Resistive load
Contact type Single
Contact material Ag-alloy (Cd free)
Rated load 8 A at 250 VAC
Rated carry current 8 A
Maximum switching voltage 380 VAC, 125 VDC
Maximum switching current 8 A
Failure rate (P level)
(reference value*) 10 mA at 5 VDC
Item Load Resistive load
Rated load 5 A at 110 VDC
Rated carry current 8 A
Maximum switching voltage 125 VDC
Rated coil voltage
Contact resistance *1 100 m
Ω
max.
Operate time 15 ms max.
Release time 5 ms max.
Max.
switching
frequency
Mechanical 18,000 operations/hr
Electrical 1,800 operations/hr
Insulation resistance *2 1,000 M
Ω
min.
Dielectric
strength
Between coil
and contacts 5,000 VAC, 50/60 Hz for 1 min
Between
contacts of
different
polarity
3,000 VAC, 50/60 Hz for 1 min
Between
contacts of
the same
polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage 10 kV (1.2 x 50
μ
s)
Insulation
distance
Between coil
and contacts
Clearance: 8 mm, Creepage: 8 mm
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 200 m/s
2
when energized
Durability
Mechanical 1,000,000 operations min. (at 18,000 operations/hr)
Electrical 10,000 operations min. (at 1,800 operations/hr
under rated load)
Ambient operating
temperature -40 to 70 °C (with no icing or condensation)
Ambient operating
humidity 5% to 85%
Weight Approx. 17 g
2
G2RG PCB Power Relay
G
2
R
G
Engineering Data
Dimensions (Unit: mm)
Approved Standards
The approved rated values for international standards are different to the individually specified characteristic values. Be sure to confirm
that required standards are satisfied before actual use.
UL Recognized: (File No. E41643)
CSA Certified: (File No. LR31928)
EN/IEC Certified Model (Approval/No. 40015012)
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Differences with the G2R
The G2RG-2A4 has the same terminal arrangement as the
G2R-2A4 but the switching capacity and electrical endurance are
different. Confirm that correct operation is possible in the actual
operating conditions before using in applications.
Model Contact form Coil ratings Contact ratings Number of test
operations
G2RG-2A4 DPST-NO (2a) 12 to 24 VDC 8 A, 250 VAC (Resistive) 70°C 10,000
Model Contact form Coil ratings Contact ratings Number of test
operations
G2RG-2A4 DPST-NO (2a) 12 to 24 VDC 8 A, 250 VAC (Resistive) 70°C 10,000
Model Contact form Coil ratings Contact ratings Number of test
operations
G2RG-2A4 DPST-NO (2a) 12, 24 VDC 8 A, 250 VAC (cosφ=1) 70°C 10,000
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 30 50 100 300 500 1,000
AC resistive load
DC resistive load
in line 2 pole
3.5
125
Ambient temperature (°C)
Maximum allowable voltage (%)
200
180
160
140
120
100
80
60
40
20
02310 30 40 50 60 70 80 90 100
110
Z'
Z
Y
Y'
X
X'
1,000
1,000
1,000
1,0001,000
1,000
Z
Z'
Shock direction
Y
Y'
XX'
Unit: m/s2
Maximum Switching Capacity Ambient Temperature vs
Maximum Coil Voltage
Note. The maximum allowable voltage is the maximum
possible value of the voltage that can be applied
to the relay coil.
Shock Malfunction
Sample: G2RG-2A4 24 VDC
Number of Relays: 5 pcs
Test conditions: Shock is
applied in ±X, ±Y, and ±Z
directions three times each with
without energizing the Relays to
check the number of
malfunctions.
Requirement: 200 m/s
2
when
energized
1 3
6
4
5 8
1
13.5 max.
(12.8)*
* Average value
(2.7)
Six, 1.3-dia. holes
5
7.5
(2.1) (2.1) 20
26.5max.
(25.7)*
3.5
0.3 0.2
29 max.
(28.6)*
0.5
G2RG-2A4 Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
(No coil porality)
Correct Use
3
G2RG PCB Power Relay
G
2
R
G
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. J142-E1-07
0316(0207)(O)
Note: Do not use this document to operate the Unit.