IELR OPERATING CHARACTERISTICS
Inrush Pulse Tolerance
Pulse tolerance is defined as a single pulse of half sine
wave 50/60Hz peak current amplitude of 8 milliseconds
duration that will not trip the circuit breaker.
PULSE TOLERANCES
Delay Pulse Tolerance
61, 62, 63 (.1 to 70 amps) 12 times (approx.) rated current
61F, 62F, 63F (.1 to 25 amps) 20 times (approx.) rated current
61F, 62F, 63F (25.1 to 70 amps) 18 times (approx.) rated current
PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C
Delay 100% 125% (Note A) 150% 200% 400% 600% 800% 1000%
41 No Trip May trip .5 to 8 .15 to 1.9 .02 to 4 .006 to .25 .004 to .1 .004 to .05
42 No Trip May trip 5 to 70 2.2 to 25 .40 to 5 .012 to 2 .006 to .2 .006 to .15
43 No Trip May trip 35 to 350 12 to 120 1.5 to 20 .012 to 2.2 .01 to .22 .01 to .1
49 No Trip May trip .100 max. .050 max. .020 max. .020 max. .020 max. .020 max.
51 No Trip .5 to 6.5 .3 to 3 .1 to 1.2 .031 to .5 .011 to .25 .004 to .1 .004 to .08
52 No Trip 2 to 60 1.8 to 30 1 to 10 .15 to 2 .04 to 1 .008 to .5 .006 to .1
53 No Trip 80 to 700 40 to 400 15 to 150 2 to 20 .015 to 9 .015 to .55 .012 to .2
59 No Trip .120 max. .100 max. .050 max. .022 max. .017 max. .017 max. .017 max.
61 No Trip .7 to 12 .35 to 7 .130 to 3 .030 to 1 .015 to .3 .01 to .15 .008 to .1
62 No Trip 10 to 120 6 to 60 2 to 20 .2 to 3 .02 to 2 .015 to .8 .01 to .25
63 No Trip 50 to 700 30 to 400 10 to 150 1.5 to 20 .4 to 10 .013 to .85 .013 to .5
69 No Trip .120 max. .100 max. .050 max. .022 max. .017 max. .017 max. .017 max.
71 No Trip .44 to 10 .3 to 7 .1 to 3 .03 to 1 .012 to .3 .004 to .15 .004 to .1
72 No Trip 1.8 to 100 1.7 to 60 1 to 20 .15 to 3 .015 to 2 .008 to .79 .006 to .28
73 No Trip 50 to 600 30 to 400 10 to 150 1.8 to 20 .015 to 10 .015 to .88 .011 to .5
79 No Trip .120 max. .100 max. .050 max. .023 max. .016 max. .015 max. .015 max.
Notes: All trip times and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of 25 C.
Protectors do not carry current prior to application of overload.
A: 135% for delays 71, 72, 73 and 79.
APL/UPL - NOMINAL DCR / IMPEDANCE
Current
Ratings
(Amps)
Resistance (ohms) Impedance (ohms) Impedance (ohms)
DC Delays AC, 50/60Hz Delays AC, 400Hz Delays
51, 52, 53, 59 61, 62, 63, 69 41, 42, 43, 49
0.20 45.8 28.5 71.94
1.0 1.38 1.10 2.85
5.0 .371 .29 .76
10.0 .055 .051 .12
15.0 .017 .016 .032
20.0 .006 .006 .010
30.0 .003 .004 .006
50.0 .0019 .0018 .0019
60.0 .00157 .00134 —
70.0 .00147 .00133 —
Notes: DCR and impedance based on 100% rated current applied and
stabilized for a minimum of one hour. Tolerance .05-2.5 amperes ± 20%; 2.6-20
amperes ± 25%; 21-70 amperes ± 50%. Consult factory for special values and
for coil impedance of delays not shown.
IELR Series - Operating Characteristics
IELR (Rail-Mount)
164