1
Power Entry Modules with Line Filter KMF
https://www.schurter.com /PG06
EMC Products
IEC Appliance Inlet with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole
Order required accessories separately
Protection class I with shield
Protection class II without shield
Approvals and Compliances
C14
70° C
C18
70° C
Description
- Panel Mount :
Snap-in version from front side
- 4 Functions :
Appliance Inlet protection class I or II , Line Switch 2-pole , Fuseholder
for fuse-links 5 x 20 mm 1- or 2-pole , Line filter in standard and medi-
cal version
- Quick connect terminals 4.8 x 0.8 mm
Unique Selling Proposition
- Most compact solution on the market
- Innovative EMC-shielding
- Easy and flexible snap-in mounting
- Protection class I or II versions
Characteristics
- Ultra-compact design. Small dimensions in front of and behind the pa-
nel
- All single elements are already wired
- For added safety "Extra-Safe" fuse drawers are available
- Innovative EMC-shielding with flexible steel segments for an excellent
contact
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Fuse drawer 1-pole, plus spare fuse case
- Fuse drawer 2-pole, with shorting bar
- Other rocker marking
References
Alternative: version without line filter KM
Alternative: version for screw mounting DD12; DD14
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 125/250 VAC;
60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Tempe-
rature
-25 °C to 85 °C
Climatic Category 25/085/21 acc. to IEC 60068-1
IP-Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I or II acc. to IEC 61140
Terminal Quick connect terminals 4.8 x 0.8 mm
Panel Thickness S Snap-in: 1/1.5/2/2.5 mm
(all steps with one variant)
Material: Housing Thermoplastic, black, UL 94V-0
appliance inlet/-outlet C14 C18 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Fuseholder 1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Rated Power Acceptance @
Ta 23 °C
5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per
pole
Power Acceptance @ Ta >
23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Line Switch 2-pole, non-illuminated, acc. to IEC
61058-1
Technical Details
Line Filter Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
MTBF > 1'800'000 h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
2
Power Entry Modules with Line Filter
KMF https://www.schurter.com /PG06
EMC Products
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: KMF
Approval Logo Certificates Certification Body Description
VDE Approvals VDE Certificate Number: 40035743
UL Approvals UL UL File Number: E72928
CQC Approvals CQC CCC File Number: 2009010204326571
Product standards
Product standards that are referenced
Organization Design Standard Description
Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Designed according to UL 1283 Electromagnetic interference filters
Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization Design Standard Description
Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets
the requirements for appliances in unattended use. This includes the en-
hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.
Compliances
The product complies with following Guide Lines
Identification Details Initiator Description
CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS SCHURTER AG EU Directive RoHS 2011/65/EU
China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1
3
Power Entry Modules with Line Filter KMF
https://www.schurter.com /PG06
EMC Products
Dimension [mm]
R1.5
30.5
50
32
10.7
L
47.5
28.5
30.4
25.7
40.4 2.5
S
0.05
max. R 0.3
47.8+0.10
-0.05
+0.10
-0.05
0
28.8
N
±
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [M]
1Standard Version 2 x 11 47 2.2 -
2Standard Version 2 x 4 47 2.2 -
4Standard Version 2 x 1.6 47 2.2 -
6Standard Version 2 x 0.7 47 2.2 -
10 Standard Version 2 x 0.4 47 2.2 -
1Medical Version (M5) 2 x 11 47 - 1
2Medical Version (M5) 2 x 4 47 - 1
4Medical Version (M5) 2 x 1.6 47 - 1
6Medical Version (M5) 2 x 0.7 47 - 1
10 Medical Version (M5) 2 x 0.4 47 - 1
4
Power Entry Modules with Line Filter
KMF https://www.schurter.com /PG06
EMC Products
Diagrams
Standard version
L
PE
N
Cx
L1
L2
F1
F2
Cy
Cy
L’
PE’
N’
1) 2)
1) Line
2) Load
Medical version (M5)
L
PE
N
Cx
L1
L2
F1
F2
L’
PE’
N’
1) 2)
R
1) Line
2) Load
Medical version (M5) protection class II
L
N
Cx
L1
L2
F1
F2
L’
N’
1) 2)
R
1) Line
2) Load
Derating Curves
1-pole
Admissible power
acceptance in Watt
020406080 100
I = << In
I = 0.7 In
I = 1.0 In
2.0
1.5
1.0
0.5
0.0
Ambient air temperature Ta °C
2-pole
Admissible power
acceptance in Watt
020406080 100
0.2
0.0
I = << In
I = 0.7 In
I = 1.0 In
1.4
0.6
0.4
1.0
0.8
1.2
Ambient air temperature Ta °C
5
Power Entry Modules with Line Filter KMF
https://www.schurter.com /PG06
EMC Products
Attenuation Loss - - - - 50 differential mode _____ 50 common mode
Standard version
1 A 2 A 4 A 6 A
10 A
Medical version (M5)
1 A 2 A 4 A 6 A
10 A
All Variants
Rated Current [A] Filter-Type Fuseholder Line Switch Protection Class Order Number
1Standard Version 1-pole 2-pole I KMF1.1211.11
2Standard Version 1-pole 2-pole I KMF1.1221.11
4Standard Version 1-pole 2-pole I KMF1.1241.11
6Standard Version 1-pole 2-pole I KMF1.1261.11
10 Standard Version 1-pole 2-pole I KMF1.1291.11
1Standard Version 2-pole 2-pole I KMF1.1111.11
2Standard Version 2-pole 2-pole I KMF1.1121.11
4Standard Version 2-pole 2-pole I KMF1.1141.11
6Standard Version 2-pole 2-pole I KMF1.1161.11
10 Standard Version 2-pole 2-pole I KMF1.1191.11
1Medical Version (M5) 1-pole 2-pole I KMF1.1213.11
2Medical Version (M5) 1-pole 2-pole I KMF1.1223.11
4Medical Version (M5) 1-pole 2-pole I KMF1.1243.11
6Medical Version (M5) 1-pole 2-pole I KMF1.1263.11
10 Medical Version (M5) 1-pole 2-pole II KMF0.2293.11
6
Power Entry Modules with Line Filter
KMF https://www.schurter.com /PG06
EMC Products
Rated Current [A] Filter-Type Fuseholder Line Switch Protection Class Order Number
10 Medical Version (M5) 1-pole 2-pole I KMF1.1293.11
1Medical Version (M5) 2-pole 2-pole II KMF0.2113.11
1Medical Version (M5) 2-pole 2-pole I KMF1.1113.11
2Medical Version (M5) 2-pole 2-pole II KMF0.2123.11
2Medical Version (M5) 2-pole 2-pole I KMF1.1123.11
4Medical Version (M5) 2-pole 2-pole II KMF0.2143.11
4Medical Version (M5) 2-pole 2-pole I KMF1.1143.11
6Medical Version (M5) 2-pole 2-pole II KMF0.2163.11
6Medical Version (M5) 2-pole 2-pole I KMF1.1163.11
10 Medical Version (M5) 2-pole 2-pole II KMF0.2193.11
10 Medical Version (M5) 2-pole 2-pole I KMF1.1193.11
Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit 20 Pcs
Required Accessory
Description
Fusedrawer 2
Fusedrawer für Fuse Links 5x20 mm, with or without Voltage Selector Insert
Fingergrip, 2-pole 4301.1401
Extra-Safe, 2-pole 4301.1403
Fingergrip, 1-pole 4301.1405
Extra-Safe, 1-pole 4301.1407
...
Accessories
Wire Harness
Wire harness for SCHURTER products
Assorted Covers
Rear Cover
0859.0076
Cord retaining kits
Cord retaining strain relief
Flat head, A 4700.0001
7
Power Entry Modules with Line Filter KMF
https://www.schurter.com /PG06
EMC Products
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091
Appliance Outlet further types to KMF
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012
Connector further types to KMF ...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Power cord with IEC connector C17, V-Lock, straight VAC17KS
Power Cord further types to KMF
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
02.12.2017
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter:
KMF1.1193.1103