NEMIC-LAMBDA NND30 Specifications *:For delivery, contact to our sales office. IA503-01-01E MODEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 ITEMS Nominal Output Voltage Maximum Output Current Maximum Output Power Efficiency (Typ) Input Voltage Range Input Current (Typ) Inrush Current(Typ) Output Voltage Range Maximum Ripple & Noise Maximum Line Regulation Maximum Load Regulation Maximum Cross Regulation Over Current Protection Over Voltage Protection Crowbar Type Remote Programming Remote Sensing Remote ON/OFF Control Parallel Operation Series Operation Operating Temperature Operating Humidity Storage Temperature Storage Humidity Cooling Temperature Coefficient (Typ) Withstand Voltage V A W (*1) % (*2) (*1) A % (*3) mV mV mV mV (*4) A (*5) V NND30 NND30 -1212 -1515 12 15 1.6 1.3 38.4 39.0 45 45 100: 85 ~ 115 VAC 115: 98 ~ 132 VAC 47 ~ 440Hz 200: 170 ~ 230 VAC 230: 195 ~ 265 VAC 1.5 1.5 20A at 100VAC, 10A at 200VAC, cold start 10 Adjustable for Each Output 1mV RMS, 3mV p-p Each Output 1.2 1.5 3.6 4.5 3.6 4.5 1.68 ~ 2.10 1.37 ~ 1.70 14.5 ~ 17.2 18.1 ~ 21.5 (*1) - -20 ~ +71C -20C : 60%, 0 ~ 50C : 100%, 60C : 60%, 71C : 40% 30 ~ 95% (No Dewdrop) -40 ~ +85C 10 ~ 95%RH (No Dewdrop) Convection Cooling 0.02% / C Input - Output : 3.75kVAC for 1min. @20mA Input - Chassis : 2.5kVAC for 1min. @20mA 27 Isolation Resistance - More than 100M at DC 500V @25C and 70%RH for 1min. 28 Vibration - 10 ~ 55Hz Amplitude (Sweep for 1min.) less than 2G X, Y, Z 1hour each 29 Shock (In package) - Less than 20G 30 Safety UL1950 - Approved by UL CSA950 - Approved by C-UL EN60950 - Approved by TUV 31 EMI - Built to meet VCCI-1, FCC Class B, VDE Class B 32 Weight g 2750 33 Size (WxHxD) (*6) mm 80 x 113.5 x 164 *Read instruction manual carefully, before using the power supply unit. OUTPUT DERATING 100 Load (%) =NOTES= *1. At 100VAC and maximum output power. *2. For cases where conformance to various safety specs. ( UL, CSA, EN etc. ) are required, input voltage will be 250VAC max. and frequency range 47-63Hz. *3. Floating output or grounded +V or -V Terminal. *4. Foldback current limit with automatic recovery for each output. *5. For each output - OVP circuit will shut down output, manual reset. (Line recycle) *6. See Outline Drawings. CURVE 80 60 40 20 0 -20 0 20 40 50 60 71 Ambient Temperature (C) NND 30 OUTPUT DERATING NEMIC-LAMBDA LOAD (%) MOUNTING : A 60 80 100 60 40 Ta (C) -20 -10 0 ~ +50 60 71 OUTPUT DERATING CURVE 100 Load (%) 80 60 40 20 0 -20 0 20 40 50 60 Ambient Temperature (C) MOUNTING : A (STANDARD MOUNTING) 71 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: NND301515