1Description
LED permanent light element, 24VAC/DC
PSD-S OE LED ...
© PHOENIX CONTACT
Data sheet
This optical signal element is part of a modular signal tower.
According to your requirements, a signal tower may com-
prise any combination of up to five signal elements. You
may use up to five optical signal elements or up to four opti-
cal and one audible signal element.
An audible signal element can be used as top element only.
A bayonet locking system establishes the mechanical and
electrical connection between the elements.
Connection elements with spring-cage or screw connection
can be used for electrical connection of the signal tower.
Mounting elements for base or tube mounting can be used
to mount the signal tower.
Features
LED permanent light element for 24VAC/DC
Colors: Red, green, yellow, blue and clear
Degree of protection: IP65, when installed or with cover
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
7949_en_01 2015-05-04
PSD-S OE LED ...
7949_en_01 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents ..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Example of a signal tower........................................................................................................ 4
6 Assembly notes for a signal tower ........................................................................................... 4
7 Assembling the individual elements......................................................................................... 5
8 Example for signal tower dimensions ...................................................................................... 5
PSD-S OE LED ...
7949_en_01 PHOENIX CONTACT 3
Description Type Order No. Pcs./Pkt.
LED permanent light element, 24VAC/DC, red PSD-S OE LED RD 2700107 1
LED permanent light element, 24VAC/DC, green PSD-S OE LED GN 2700119 1
LED permanent light element, 24VAC/DC, yellow PSD-S OE LED YE 2700122 1
LED permanent light element, 24VAC/DC, clear PSD-S OE LED CL 2700127 1
LED permanent light element, 24VAC/DC, blue PSD-S OE LED BU 2700131 1
3Ordering data
4 Technical data
Dimensions (in mm)
Diameter 70 mm
Height 65.5 mm
Ø70
65,5
56
General data
Material Polycarbonate PC
Calotte color : PSD-S OE LED RD red
Calotte color : PSD-S OE LED GN green
Calotte color : PSD-S OE LED YE yellow
Calotte color : PSD-S OE LED CL clear
Calotte color : PSD-S OE LED BU blue
Weight 58 g
Ambient temperature (operation) -30 °C ... 50 °C
Degree of protection IP65, when installed or with cover
Mounting position any
Connection Rubber seal pre-installed for each element
Electrical data
Input voltage 24 V AC/DC
Inrush current max. 500 mA
Current consumption 30 mA
Optical signal type Permanent light
PSD-S OE LED ...
7949_en_01 PHOENIX CONTACT 4
5 Example of a signal tower
Figure 1 Example of a signal tower
Key:
1Audible signal element
2Optical signal element
3Connection element
4Assembly element
6 Assembly notes for a signal tower
Only use a maximum of five elements within a signal
tower.
Use only one audible element in a signal tower and po-
sition this element on top.
When closing the bayonet locking system, observe the
markings (see "Assembling the individual elements").
Source of light type LED
Service life, electrical max. 100,000 h
Operating time 100 %
Electrical data
Approvals / conformities
Conformance with EMC Directive 2004/108/EC
For the latest approvals, please visit phoenixcontact.net/products.
1
2
3
4
PSD-S OE LED ...
7949_en_01 5
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
7 Assembling the individual ele-
ments
Figure 2 Assembling the individual elements
Select the elements for your application.
Connect the elements to be assembled so that the
markings are aligned.
Turn the upper element in the direction of the arrow.
8 Example for signal tower dimen-
sions
The following figure shows the dimensions of a typical signal
tower.
Figure 3 Dimensions of a signal tower (example)
123
ON
123
ON
123
ON
123
ON
123
ON
123
ON
56
112
86
4x56 (= 224)
408
Ø70