Temperature & Voltage Scanning Instruments
TempScan/1100
Measures thermocouples, volts, &
RTDs at up to 960 channels/s
Accepts optional scanning modules
for measuring thermocouples, RTDs,
or DC volts
Expandable up to 992 channels
MultiScan/1200
Measures isolated temperature, DC
volts, AC volts, & waveforms in one
compact instrument
Scans thermocouples & DC volts at
up to 147 channels/s
Single-channel burst mode for digitiz-
ing waveforms at rates up to 20 kHz
Two scanning modules available for
measuring 24 channels of thermo-
couples/volts or high voltage, respectively
Expandable up to 744 channels
Common Features
IEEE 488 & RS-232/422 interfaces
32 TTL digital alarm outputs & 8 TTL-
compatible digital inputs
Custom thermocouple types for user-
defined linearization tables
Two programmable scan rates for:
-pre-trigger & post-trigger sampling
-accelerated sampling on-event
detection
128 Kreadings of memory, expand-
able up to 4 Mreadings
Built-in real-time clock:
-synchronizes acquisition to time
of day
-provides time & date stamping for
trend monitoring
Software (see p. 227)
ChartView, an Out-of-the-Box data
logging application for effortless setup,
acquisition, & real-time display
DIAdem®-View, for post-acquisition
viewing of data files
ScanCal, calibration software
LabVIEW®
MultiScan/1200
Measurement Parameters
A/D resolution 16 bit w/oversampling 16 bit w/oversampling
Accuracy (w/J thermocouple) ±0.5°C±0.5°C
Thermocouples supported J,K,T,E,R,S,B,N J,K,T,E,R,S,B,N
RTD
DCV
ACV
Channel-to-channel isolation 10V 500V or 200V
Channel-to-system isolation 500V 500V
AC line rejection
Scanning Parameters
Switching technology solid state multiplexers mechanical relays
Max scan rate 960 channels/s 147 channels/s
Max single-channel scan rate 60 Hz 20 kHz
Min channel configuration 32 channels 24 channels
Max channel configuration 992 channels 744 channels
Data Handling
Built-in memory 256 Kbyte 256 Kbyte
Max memory with expansion 8 Mbyte 8 Mbyte
IEEE 488 interface
RS-232 interface
RS-422 interface
Time and date stamping
Triggering
Digital trigger input
Analog trigger input
Trigger on time of day
Pre-trigger scan rate programmable programmable
Post-trigger scan rate programmable programmable
Digital Inputs 8 8
Programmable Alarm Outputs 32 32
Software
ChartView included included
LabVIEW drivers
DASYLab drivers
Hardware Options
32-ch TC scanning card TempTC/32B
32-ch voltage scanning card TempV/32B
16-ch RTD scanning card TempRTD/16B
24-ch TC/voltage scanning card MTC/24
24-ch high voltage scanning card MHV/24
2-slot expansion chassis Exp/10A Exp/10A
10-slot expansion chassis Exp/11A Exp/11A
TempScan/1100
Temperature Series Selection Guide
The TempScan/1100 and MultiScan/1200 offer high-speed temperature and voltage
measurement in compact, 19-in. rack-mountable enclosures
TempScan/1100
& MultiScan/1200
High-Speed Temperature & Voltage
Scanning Instruments
*
UPDATED: 3/29/01
215
QUICK FIND
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
tel: 440-439-4091 fax: 440-439-4093 sales@iotech.com www.iotech.com
The TempScan/1100 and MultiScan/1200 are
high-speed, compact, rack-mountable instru-
ments that measure up to 992 or 744 channels
of temperature or voltage, respectively.
Because of their unique architecture, both
instruments offer unrivaled low cost per
channel. They connect to a computer via
IEEE 488, RS-232/422, or Hayes-compatible
modem and can be disconnected from the
PC for stand-alone operation.
TempScan/1100
The TempScan/1100 is well suited for
temperature and lower-voltage measure-
ment because its solid state scanning pro-
vides temperature readings at speeds up
to 960 channels/s, an important feature
in applications that require monitoring
of tens or hundreds of channels.
MultiScan/1200
The MultiScan/1200 is ideal for tempera-
ture and voltage measurements that re-
quire more channel-to-channel isolation
than the TempScan/1100 can offer. The
unit provides 500V of channel-to-chan-
nel isolation for voltage and 200V of chan-
nel-to-channel isolation for thermo-
couples. The MultiScan/1200 uses relays
to provide isolation and to scan thermo-
couples and volts at up to 147 channels/s.
The unit can also digitize waveforms on a
single channel at up to 20 kHz.
TempScan/1100
& MultiScan/1200
Temperature & Voltage Instruments
The TempScan/1100 and MultiScan/1200 include ChartView Out-of-the-Box software,
a Microsoft Windows application that enables measurements without programming
Software
The TempScan/1100 and MultiScan/1200 include ChartView, one of IOtech’s
Out-of-the-Box, Windows®-based setup and acquisition applications. ChartView provides
a graphical spreadsheet-style user interface that lets you easily configure your hardware,
acquisition, and display parameters. Compatible with Windows® 3.x/95/2000/NT,
ChartView features a no-programming approach that enables data collection and display
within minutes of taking your TempScan/1100 or MultiScan/1200 Out-of-the-Box. For
more information about ChartView, see p. 228.
In addition to ChartView data-logging software, every TempScan/1100 and
MultiScan/1200 also ships with DIAdem®-View, a post-acquisition data-review pro-
gram, and ScanCal, an application that automates instrument calibration. For more
information about DIAdem-View, see p. 198.
When combined with a Net232 Ethernet interface, optional ScanServer** software
(see p. 240) permits access to any number of TempScans or MultiScans from all popular
SCADA/HMI applications, such as those from Wonderware® and Intellution®. ScanServer
supports all OPC/DDE-compliant environments, including Microsoft® Excel.
Free software drivers are also available for a wide range of programming environments,
including LabVIEW®* for Windows®.
* IEEE-488 and RS-232 support
** Contact factory for availability
QUICK FIND
tel: 440-439-4091 fax: 440-439-4093 216 sales@iotech.com www.iotech.com
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
Scanning Modules
IOtech’s TempScan/1100 and MultiScan/1200
eliminate the need for external signal
conditioning, multiplexers, and custom
cables, thereby saving you both time and
money. Their user-installable scanning
modules provide all required signal
conditioning and amplification.
The units’ scanning modules contain
screw-terminal sockets for quick and easy
input connections. The modules slide into
a metal, shielded enclosure within the
TempScan/1100 or MultiScan/1200, keep-
ing noise to a minimum and maintaining
a constant internal temperature.
When equipped with the Exp/10A or
Exp/11A (p. 217) expansion chassis, the
TempScan/1100 and MultiScan/1200
can accept multiple scanning modules,
allowing you to create systems of up to
992 channels (TempScan/1100) and 744
channels (MultiScan/1200).
TempScan/1100
& MultiScan/1200
Scanning Modules
TempScan/1100 Modules MultiScan/1200 Modules
Applications
Temperature
Low voltage
High voltage
No. of channels 24 24
Scanning Modules MTC/24 MHV/24
MultiScan/1200 Scanning Module Selection Guide
TempTC/32B TempRTD/16B TempV/32B
Applications
Temperature
Low voltage
High voltage
No. of channels 32 16 32
Scanning Modules
TempScan/1100 Scanning Module Selection Guide
The TempScan/1100 is supported by three
solid-state scanning modules including:
TempTC/32B Thermocouple Scanning
Module. The TempTC/32B thermocouple
scanning module contains 32 differential
input channels, each of which may be con-
figured for thermocouple types J, K, T, E, R,
S, B, and N, or for a ±100 mV input. Mea-
surements may be designated in units of ˚C,
˚F, ˚K, ˚R, or volts.
TempRTD/16B RTD Scanning Module.
The TempRTD/16B scanning module sup-
ports 16 channels of 3- or 4-wire RTDs.
Measurements may be designated in units
of ˚C, ˚F, ˚K, or ˚R.
The MultiScan/1200 can accept one of
two available scanning modules, each of
which features 24 input channels. These
scanning modules include:
TempV/32B Voltage Scanning Module. The
TempV/32B scanning module contains 32
differential input channels and is capable of
measuring voltage with programmable ranges
of ±10V, ±5V, ±1V, and ±100 mV.
MTC/24 Thermocouple/Volt Scanning
Module. The MTC/24 provides 24 iso-
lated differential input channels, and
per-channel programmability for ther-
mocouple types J, K, T, E, R, S, B, and N,
or for ±10V, ±5V, ±1V, and ±100 mV
inputs. Channel-to-channel isolation is
200 VDC peak.
MHV/24 High-Voltage Scanning
Module. The MHV/24 provides 24 differ-
ential voltage-input channels, and per-
channel programmability for ±250V,
±25V, and ±2.5V. Channel-to-channel
isolation is 500 VDC peak.
217
QUICK FIND
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
tel: 440-439-4091 fax: 440-439-4093 sales@iotech.com www.iotech.com
TempScan/1100
& MultiScan/1200
Expansion Ar chitecture
The TempScan/1100 and MultiScan/1200 can each accept one
scanning module, which provides all of the required signal condi-
tioning. If your application demands more channels than are
available on a single module, you can use either the 2-slot Exp/10A
or the 10-slot Exp/11A expansion chassis. Multiple Exp/10A and
Exp/11A chassis can be daisy chained to a TempScan/1100 or
MultiScan/1200, providing up to 30 additional slots. Regardless of
the number of expansion chassis connected, there is only one link
to the computer, via its IEEE 488 or serial interface. As a result, the
TempScan/1100 or MultiScan/1200 appears to the PC as one
unified multichannel instrument.
TempScan/1100 and
MultiScan/1200 Expansion
The TempScan/1100 and MultiScan/1200 instruments can each
control up to 15 Exp/10A two-slot expansion chassis. The
Exp/10A’s form factor is identical to that of either instrument.
When attached to the TempScan/1100, the Exp/10A is config-
urable for 32 or 64 input channels, providing a total expansion
capacity of up to 992 channels. When attached to the
MultiScan/1200, the Exp/10A is configurable for 24 or 48 input
channels, providing a total expansion capacity of up to
744 channels.
For TempScan/1100 systems consisting of more than 96
channels, the 10-slot Exp/11A expansion chassis provides an
economical and convenient solution. One Exp/11A provides
up to 320 input channels in a compact and convenient
enclosure. Multiple Exp/11A chassis can be connected to one
TempScan/1100 to provide a total system capacity of up to
992 channels.
For MultiScan/1200 systems of more than 72 channels, the
10-slot Exp/11A is recommended and accommodates up to 240
input channels. Multiple Exp/11A chassis can be connected to
one MultiScan/1200 providing a total system capacity of up to
744 channels.
Exp/10A 2-slot expansion chassis Exp/11A 10-slot expansion chassis
Up to 15 Exp/10A expansion chassis can be
attached to a TempScan/1100 or MultiScan/1200
To computer
(RS-232/422 or IEEE 488)
Exp/10A
2-slot expansion chassis
Exp/10A
2-slot expansion chassis
TempScan/1100
or MultiScan/1200
The TempScan/1100 or MultiScan/1200 can
support up to three Exp/11A expansion chassis
To computer
(RS-232/422 or IEEE 488)
Exp/11A
10-slot expansion chassis
Exp/11A
10-slot expansion chassis
Exp/11A
10-slot expansion chassis
TempScan/1100
or MultiScan/1200
QUICK FIND
tel: 440-439-4091 fax: 440-439-4093 218 sales@iotech.com www.iotech.com
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
TempScan/1100
& MultiScan/1200
Measurement Modes
MultiScan/1200
The MultiScan/1200 offers three measuring modes for applica-
tion flexibility. These include a line-cycle integration mode, a
high-speed multichannel scanning mode, and a single-channel
burst mode. A discussion of the particular attributes of each
measuring mode follows.
Single-
Channel
Burst Mode
Measurement Mode
Line
Cycle
Integration
T/C
DCV
ACV
High-Speed
Multichannel
Scanning
TempScan/1100
Scan Technique. The TempScan/1100 uses a technique whereby
groups of 16 consecutive channels are scanned during every AC
line cycle (i.e., channels 1 to 16 are scanned during the first AC
line cycle, channels 17 to 32 are scanned during the subsequent
AC line cycle, and so forth). This results in maximum measure-
ment rates of 960 channels per second (60 Hz) or 800 channels
per second (50 Hz).
Per Channel Scan Rate1,2,3,4: The rate at which
individual channel values are updated depends on the
total number of channels scanned and the AC line
frequency (60/50 Hz).
* channels/s
DC Volts &
Thermocouples
50 Hz 60 Hz
1 38.5* 44*
219.2* 22*
49.6* 11*
AC
Volts
50 Hz 60 Hz
38.5* 44*
Maximum
Channel
Number
8 4.8* 5.5*
741
431
234
122
Line
Cycles
per
Reading
Line Cycle Integration
Scan Interval. For applications that require the logging of data
at a specified time interval, the TempScan/1100 offers a pro-
grammable scan interval. The effect of the scan interval is
illustrated in the example below.
Line-Cycle Integration Mode. The MultiScan/1200’s ability to
sample and average 32 measurements per line cycle makes it
useful for high-accuracy applications and is recommended for
thermocouple measurements. What’s more, when engaged in
line-cycle averaging, the unit provides AC or DC voltage, or
linearized and compensated thermocouple-based temperature
readings at up to 44 channels/s. The MultiScan/1200’s AC
voltage measurement capability is ideal for power-line monitor-
ing applications. For each measurement, the unit calculates the
equivalent true RMS voltage based on 32 samples it acquires
during each AC line cycle.
High-Speed, Multichannel Scanning Mode. When the
MultiScan/1200’s line-cycle averaging is disabled, the unit can
average 1, 2, 4, 8, 16, or 32 samples per channel. When the unit
is configured to take one sample per channel, it can scan 147
channels/s—or all of its potential 744 expansion channels in
approximately 5 seconds. This is important if the application
involves monitoring tens to hundreds of channels. By contrast,
data loggers and other temperature measuring instruments
typically acquire readings at only 5 to 20 channels/s.
Single-Channel Burst Mode. In single-channel burst mode, the
MultiScan/1200 can sample at up to 20 kHz on a single channel and
store the data in its memory, which can be expanded up to
8 Mbytes. When performing post-acquisition waveform analysis
such as Fast Fourier Transforms (FFTs), the unit can return each data
point in a waveform to your program. Alternatively, the unit can
provide a true RMS value of the equivalent AC voltage.
1. All thermocouple measurements are cold-junction compensated and linearized
2. Per-channel scan rate may be lower if channels are skipped
3. The per-channel scan rate may be calculated using the formula at right:
4. Divide the per-channel scan rate by 4 if using thermocouple wire > 500 ft.
AC line frequency
INT Number of channels +15
16
1-16 60 50
17-32 30 25
33-48 20 16.7
49-64 15 12.5
65-80 12 10
81-96 10 8.3
97-112 8.6 7.1
113-128 7.5 6.25
785-800 1.2 1.0
945-960 1.0 .83
961-976 .98 .82
977-992 .97 .81
Number of Channels Per Channel Scan Rate (Hz)
60 Hz 50 Hz
The TempScan/1100’s programmable scan interval controls the time
between successive channel scans, as illustrated in the above
example for a 32-channel system
Scan Interval = 100 msec
Acquire: Data, alarms, and high, low,
and last statistics are updated Monitor: Only alarms and high, low,
and last statistics are updated
Acquire Acquire
Monitor Monitor
16.67 33.33
t=0 t (msec)
100 116.67 133.33
Scan Interval
Channels
1-16 Channels
17-32 Channels
1-16 Channels
17-32
219
QUICK FIND
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
tel: 440-439-4091 fax: 440-439-4093 sales@iotech.com www.iotech.com
TempScan/1100
& MultiScan/1200
General Information
Scanning Capabilities
The TempScan/1100 and the MultiScan/1200 provide an array of
scanning capabilities to meet your application requirements. Be-
cause data-logging applications frequently require the logging of
readings at fixed time intervals, the TempScan/1100 and the
MultiScan/1200 use the standard hours-minutes-seconds
(hh:mm:ss.s) format to specify the time interval between channel
scans. Users can configure the units to begin and end data logging
on a specified event—such as a TTL signal, temperature level, IEEE
GET, alarm condition, or absolute time of day—or upon completion
of a specified number of readings.
Two Programmable Scan Rates. The TempScan/1100 and the
MultiScan/1200 offer two programmable scan rates for applica-
tions that require acceleration of the measurement rate on a
specified event, such as an alarm condition. For example, you can
program the instruments to sample once per minute and then,
upon the occurrence of a specified alarm condition, switch to
sampling once per second. Upon cessation of the alarm condition,
the units resume sampling at the rate of once per minute.
Accuracy
The TempScan/1100 and the MultiScan/1200 have a number of
features and capabilities that enable them to deliver the high
accuracy demanded by many research applications.
High Resolution. Each unit is equipped with a high-speed
16-bit A/D converter. This enables the TempScan/1100 to offer
up to 0.1˚C and 3.05 µV resolution with the TempTC/32B
scanning module and allows the MultiScan/1200 to offer the
same with the MTC/24 scanning module.
Noise Filtering. The TempScan/1100 filters AC line cycle
noise by sampling and averaging 16 measurements per line
cycle. The MultiScan/1200 does so by sampling and averag-
ing 32 measurements per line cycle. The MultiScan/1200 also
offers the additional flexibility to average across multiples of
1, 2, 4, or 8 line cycles.
High-Accuracy Cold Junction Compensation. The TempTC/32B
and the MultiScan/1200’s MTC/24 thermocouple/volt scan-
ning modules both feature multiple, strategically located tem-
perature sensors that provide high-accuracy, cold-junction com-
pensation across all of its inputs.
Accurate Linearization. The TempScan/1100 and the MultiScan/1200
enable quick and accurate linearization by providing built-in
lookup tables for popular thermocouple types, including J, K, T,
E, R, S, B, and N. The units can also store up to two user-defined
lookup tables in nonvolatile RAM (NVRAM) for use with user-
defined thermocouple linearization curves.
Alarms
Many process-control applications require periodic monitoring
until the occurrence of an alarm condition; then they require the
acceleration of measurement and the provision of closed-loop
control signals until the process returns to a steady state.
The TempScan/1100 and the MultiScan/1200 offer a number of
capabilities and features that facilitate such applications. For
example, they provide 32 digital alarm outputs that can be acti-
vated on a per-channel basis via user-specified alarm conditions,
and they automatically return their alarm outputs to steady state
once limit conditions are resolved.
The units’ ability to automatically update alarm outputs in real-
time affords you greater control of your applications and re-
duces your programming burden by eliminating the need for
constant, per-channel monitoring by the controlling computer.
In addition, the units can update alarmed output channels in
real time, at their programmed scan rates, and can alert the host
computer of active alarm conditions via an IEEE 488 service
request (SRQ).
Real-T ime Clock
The TempScan/1100 and the MultiScan/1200 each feature a
real-time clock that allows you to synchronize acquisition to a
specific time of day. During acquisition, the TempScan/1100
and the MultiScan/1200 store the time and date of every data
scan in memory, enabling later retrieval of this information for
use in plotting and analyzing measurements over time. The
instruments also time and date stamp each channel’s high and
low excursions, providing a precise time record of a channel’s
minimum and maximum values.
Memory
For high-speed and long-term data logging, the
TempScan/1100 and the MultiScan/1200 are equipped with
128 Kreadings of data storage, which can be field upgraded by
the user to 4 Mreadings. Because individual measurements
are not necessary for all data logging applications, the units
make each channel’s high, low, and last readings available
throughout acquisition.
QUICK FIND
tel: 440-439-4091 fax: 440-439-4093 220 sales@iotech.com www.iotech.com
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
TempScan/1100
& MultiScan/1200
Communication
PC
TempScan/1100
or MultiScan/1200
MultiScan/1200
MultiScan/1200
TempScan/1100
or MultiScan/1200
MultiScan/1200
TempScan/1100
or MultiScan/1200
Serial Communication
Product
Serial cables
IEEE 488 & RS-232/422 Control
The TempScan/1100 and the MultiScan/1200 are equipped with
both a high-speed IEEE 488 interface and an RS-232/422 interface.
IEEE 488. The TempScan/1100 and the MultiScan/1200’s IEEE
488 interface can transfer data at up to 300 Kbytes/s. The
interface lets you log readings directly to a controlling computer’s
hard disk in real time, making it compatible with IOtech’s
complete line of IEEE 488.2 controllers for PCs (see p. 263).
RS-232/422. The TempScan/1100 and the MultiScan/1200’s
RS-232/422 interface can connect directly to a notebook or
desktop PC’s serial port. This makes the units suitable for
process control and environmental control, as well as for
other applications that require instruments to be located
remotely from the controlling computer.
The RS-232/422 interface provides switch-selectable baud rates
from 300 to 9600. The units’ RS-232/422 port also enables their
use with IOtech’s complete line of Serial Communication Boards
(see p. 297). These boards let users control multiple test stations
from one PC, enabling them to perform data acquisition at
multiple, distant locations.
PC
TempScan/1100
or MultiScan/1200
MultiScan/1200
MultiScan/1200
TempScan/1100
or MultiScan/1200
MultiScan/1200
TempScan/1100
or MultiScan/1200
Personal488
Communication
Product
IEEE 488 cables
Command Summary
Alarm Detecting and Posting Commands
A Assign Alarm Output
Buffer Operation Commands
*B Flush Output Buffer
*T Scan Time Stamping
R Read Data Buffer
A# Scan Alarm Stamping
R# Read Last Readings
Calibration Commands
*G Set RTD Gain Calibration Reference
*K Change Calibration Keyword
*P Adjust Calibration Card Pots
E End Calibration Mode
G Calibrate Channel Gain
H Calibrate Channel Offset
J Calibrate Cold Junction Offset
K Enter Calibration Mode
C# Select Card Number
QC? Query Calibration Data
System Commands
*R Power-On Reset
*S Power Up Settings
*W Software Digital Filtering
F Data Format
L# Set Slow/Fast Rate
O Set Digital Outputs
Q Query Terminator
S Set Real Time Clock
V Set User Terminator
X Execute
Channel Configuration Commands
*C Clear Channel Config
C Configure Channels
Event/Error Detection and Posting Commands
E? Error Status
M SRQ Mask
N Event Mask
NVRAM Commands
*F Restore Factory Settings
Acquisition Configuration Commands
@ Trigger on Command
I Set Scan Interval
L Set Trigger Level
P Program Trigger Times
T Trigger Configuration
Y Set Counts
Status Reporting Commands
U User Status
Custom Table Operation Commands
D Define Custom Table
W Set Table Entry Pointer
Z Load Current Entry
TempScan/1100 & MultiScan/1200
System Examples
System example connecting to an IEEE 488 controller
System example showing direct connection
to the PC’s serial port
221
QUICK FIND
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
tel: 440-439-4091 fax: 440-439-4093 sales@iotech.com www.iotech.com
5. TTL output (BNC) connector: TTL output signal occurs for each channel scan;
used for synchronizing other equipment with TempScan/1100 or MultiScan/1200
acquisition, such as IOtech’s Digital488 and DAC488 products
6. Alarms and digital input/output (DB50) connector: Provides easy access to
32 TTL digital alarm outputs and 8 digital input lines
7. Master/slave (DB25) connector: Connection to Exp/10A or Exp/11A expansion
units for greater channel expansion
8. Shielded enclosure: Accepts scanning modules (TempTC/32B, TempV/32B,
TempRTD/16B, MTC/24 or MHV/24); designed to keep noise outside and a
constant temperature inside
9. Power input connector: Internally configurable for either 105-125 or 210-250
VAC, 50/60 Hz, plus fuse circuit breaker
10. Power on/off switch
11. CA-35-1 master/slave cable (included with both Exp/10A and Exp/11A
expansion chassis)
TempScan/1100 and MultiScan/1200
Rear Panel
1. IEEE 488 connector: Provides full IEEE 488 control from PCs
2. RS-232C/RS-422 (DB9) connector: Serial port for operation at remote dis-
tances from controlling computer; supports 300 to 9600 baud using RTS/CTS
or XON/XOFF handshaking
3. DIP switches: Easy-to-access switches for selecting IEEE 488 or RS-232/422
communication and respective parameters (IEEE 488: Address; RS-232/422:
handshaking, parity, and baud rate)
4. Trigger input (BNC) connector: For initiating and/or stopping acquisition
with TTL input signal
Exp/10A Rear Panel
12. DIP switches: Easy-to-access switches for selecting Exp/10A slave ID
13. Master/slave (DB25) connectors: Provides connection from the
TempScan/1100 or MultiScan/1200 to one or more expansion chassis
14. Shielded enclosure: Accepts any combination of scanning modules for use
with their respective systems (TempTC/32B, TempV/32B, TempRTD/16B,
MTC/24 or MHV/24)
15. Power input connector: Internally configurable for either 105-125 or 210-250
VAC, 50/60 Hz, plus fuse circuit breaker
16. Power on/off switch
Exp/11A Rear Panel
17. Master/slave (DB25) connectors: Provides connection from the Temp-
Scan/1100 or MultiScan/1200 to one or more expansion chassis
18. Shielded enclosure: Accepts any combination of scanning modules for use
with their respective systems (TempTC/32B, TempV/32B, TempRTD/16B,
MTC/24, or MHV/24)
19. Power input connector: Internally configurable for either 105-125 or 210-250
VAC, 50/60 Hz, plus fuse circuit breaker
20. Power on/off switch
TempScan/1100
& MultiScan/1200
Instrument Part Identification
9
2
3
5
4
6
11
78
14
18
10
1
16
15
12 13
13 14
19
20
17
QUICK FIND
tel: 440-439-4091 fax: 440-439-4093 222 sales@iotech.com www.iotech.com
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
Specifications
TempScan/1100 & MultiScan/1200
Number of Slots: 1
Number of Channels
TempScan/1100: Up to 32 differential thermocouple or voltage inputs, or up
to 16 RTD inputs; accepts TempTC/32B, TempV/32B, or TempRTD/16B scan-
ning modules
MultiScan/1200: Up to 24 differential thermocouple or voltage inputs;
accepts MTC/24 or MHV/24 scanning modules
Channel Attributes: High and low set points; hysteresis value for high and low
set points
Scan Sequence: Any combination of temperature and voltage channels may be
scanned, but channels are scanned in ascending numerical order
Scan Interval: Absolute time between channel scans; minimum = 1 ms
(TempScan/1100), 6.8 ms (MultiScan/1200); maximum = 99:59:59.9
(hh:mm:ss.s)
Scanning Modes
TempScan/1100:
960 channels/s (60 Hz); 800 channels/s (50 Hz)
for thermocouples up to 500 ft.
240 channels/s (60 Hz); 200 channels/s (50 Hz)
for thermocouples over 500 ft.
MultiScan/1200:
147 channels/s (50/60 Hz)
multi-channel scanning
44 channels/s (60 Hz); 38.5 channels/s (50 Hz),
with 32-point line-cycle averaging enabled
1 channel @ 20 Ksamples/s,
single-channel burst mode
Programmable Triggering: Temperature or voltage level (above or below),
absolute time of day, alarm condition (on or off), IEEE GET, IEEE TALK,
external TTL trigger (rising or falling), specified number of readings
Level Trigger: Programmable value for any one channel
(not available when the MultiScan/1200 is in single-channel burst mode)
TTL Trigger: Programmable for rising or falling edges
Pre-Trigger Count: Programmable (< memory size - 1)
Post-Trigger Count: Programmable
Alarms & Digital I/O
Number of Digital Alarm Outputs: 32 bits, TTL-level compatible
Number of Digital Inputs: 8 bits, TTL-level compatible
Connector: 50-pin D-connector; mating connector supplied
Alarm Conditions: May be detected by SRQ or software query (SPOLL or U
Command)
Data Storage & Format
Storage: 128 Kreadings standard; optional 500 Kreadings, 2 Mreadings, and
4 Mreadings user-installable
Data Formats: ASCII or binary; binary format returns a 16-bit compensated &
linearized temperature value (0.1˚C/bit); user programmable for hi byte/lo
byte or lo byte/hi byte
Note: High-speed DMA transfers are binary format only
Statistical Parameters: High, low, and last available per channel
(not available when the MultiScan/1200 is in single-channel burst mode)
Time Stamp: Available for each scan group and for each channel’s high, low, and
last parameters (not available when the MultiScan/1200 is in single-channel
burst mode)
Time Format:
1. Absolute date and time (mm/dd/yy hh:mm:ss.sss)
2. Relative time (±hh:mm:ss.sss,DDDDDDD)
IEEE 488 Interface
Implementation: SH1, AH1, T6, TE4, L4, LE4, SR1, PP0, RL0, DC1, DT1, C0, & E1
Programmable Parameters: Alarm set points, thermocouple types, temperature
units, trigger level, pre-trigger and post-trigger scan interval, trigger mode, SRQ
mask, scan count, pre-trigger count, digital input, digital output, real-time
clock, data output format, and terminators
Maximum Data Transfer speed: 300 Kbytes/s
Connector: Standard IEEE 488 connector with metric studs
RS-232/422 Interface
Baud Rates: 300, 1200, 2400, 4800, 9600, 19200
Data Bits: 8
Stop Bits: 1
Parity: Even, odd, none
Handshaking: RTS/CTS, XON/OFF
Connector: Male DB-9
Calibration
Calibration Cycle: One year
Calibration Constants: Chassis constants stored in nonvolatile memory; card
constants stored in EEPROM; each unit includes ScanCal, example software for
automating its calibration procedure; calibration is enabled via software
password and by hardware enable switch
General
Front Panel Indicators: LEDs for alarm, scanning, talk, listen, SRQ, error, send,
receive, power, and trigger status
Power: 105 to 125 or 210 to 250 VAC, 50/60 Hz; 20 VA max
Warm-Up: One hour to rated accuracy
Environment: 0˚ to 50˚C; 0 to 95% RH, non-condensing to 35˚C; linearly derate
3% RH/˚C from 35˚C to 50˚C
IEEE 488 Connector: Standard IEEE 488 connector with metric studs
RS-232/422 Connector: Male DB-9
Master/Slave Port: Female DB25
Digital I/O and Alarms: Female DB50 (32 alarms, 8 digital inputs, 10
ground pins)
Trigger Input: BNC
TTL Output: BNC
Configuration Switches: IEEE 488 or RS-232/422, IEEE 488 address, handshake,
parity, baud rate, and calibration-memory write enable/disable
Dimensions: 425 mm W x 305 mm D x 45 mm H (16.75” x 12” x 1.75”)
Weight: 3.62 kg (8 lbs)
Exp/10A Expansion Chassis
Number of Slots: 2
Number of Channels
TempScan/1100: Up to 64 differential voltage or thermocouple inputs, or up
to 32 RTD inputs; accepts any combination of two TempTC/32B, TempV/32B,
and TempRTD/16B scanning modules
MultiScan/1200: Up to 48 differential voltage or thermocouple inputs;
accepts any combination of two MTC/24 and MHV/24 scanning modules
Front Panel Indicators: LEDs for scanning, error, and power
Power: 105 to 125 or 210 to 250 VAC, 50/60 Hz; 20 VA max
Environment: 0˚ to 50˚C; 0 to 95% RH, non-condensing to 35˚C; linearly derate
3% RH/˚C from 35˚ to 50˚C
Rear Panel
Configuration Switches: DIP switch for setting slave ID
Master/Slave Ports: Two female DB25 ports
Cabling: Included for connection to mainframe or other expansion device
Dimensions: 425 mm W x 305 mm D x 45 mm H (16.75” x 12” x 1.75”)
Weight: 2.53 kg (5.5 lbs)
Exp/11A Expansion Chassis
Number of Slots: 10
Number of Channels
TempScan/1100: Up to 320 differential voltage or thermocouple inputs, or up
to 160 RTD inputs; accepts any combination of 10 TempTC/32B, TempV/32B,
and TempRTD/16B scanning modules
MultiScan/1200: Up to 240 differential voltage or thermocouple inputs;
accepts any combination of 10 MTC/24 and MHV/24 scanning modules
Front Panel Indicators: LEDs for scanning, error, and power
Power: 105 to 125 or 210 to 250 VAC, 50/60 Hz; 20 VA max
Environment: 0˚ to 50˚C; 0 to 95% RH, non-condensing to 35˚C; linearly derate
3% RH/˚C from 35˚ to 50˚C
Rear Panel
Configuration Switches: DIP switch for setting slave ID
Master/Slave Ports: Two female DB25 ports
Cabling: Included for connection to mainframe or other expansion device
Dimensions: 425 mm W x 305 mm D x 135 mm H (16.75” x 12” x 5.25”)
Weight: 6.36 kg (14 lbs)
TempScan/1100
& MultiScan/1200
Specifications
223
QUICK FIND
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
tel: 440-439-4091 fax: 440-439-4093 sales@iotech.com www.iotech.com
TempScan/1100
& MultiScan/1200
Specifications
Accuracy: ± 0.02%
Digital Filtering: Averages 16 samples at 50/60 Hz for line cycle noise rejection
Temperature Coefficient: <0.01%/˚C
Input Impedance: 1M Ohm typ
Input Bias Current: 40 nA max
Common Mode Rejection: 100 dB typ
Maximum Allowable Input: 25V rms max
Channel-to-Digital Low Isolation: 500V max
Channel-to-Channel Isolation: ±10V peak
Channel-to-Channel Cross Talk: 100 dB min
MultiScan/1200 Scanning-Module Specifications
MTC/24—Thermocouple Scanning Module
Number of Channels: 24 differential; programmable by channel for specific
thermocouple type or a voltage input
Input Types: J, K, T, E, R, S, B, N, custom thermocouple, and voltage
Input Connectors: Screw terminal
Maximum Allowable Input: ±25V rms
Input Impedance: 1M Ohm
Input Bias Current: 20 nA max
Maximum Common Mode Voltage 1,2, 11: 200 VDC or AC peak
Maximum Normal Mode Voltage11: 10 VDC or AC peak
Channel-to-Power Ground Isolation: 200V peak
Channel-to-Channel Isolation11: 200V peak
Temperature Coefficient: <(0.1 x rated accuracy)%/˚C
Digital Filtering: Averages 32 samples at 50/60 Hz for line-cycle noise rejection
(DCV and thermocouple measurements)
Temperature Specifications
Thermocouple Wire: #20 AWG recommended (#16 AWG max/#24 AWG min)
Temperature Range and Accuracy 3,4:
Type Range Accuracy5, 10 Resolution
J -100˚ to +760˚C ±0.5˚C 0.10˚C
-200˚ to -100˚C ±0.8˚C 0.20˚C
K -100˚ to +1372˚C ±0.6˚C 0.10˚C
-200˚ to -100˚C ±0.8˚C 0.20˚C
T -100˚ to +400˚C ±0.5˚C 0.15˚C
-200˚ to -100˚C ±0.8˚C 0.25˚C
E -100˚ to +1000˚C ±0.7˚C 0.10˚C
-200˚ to -100˚C ±0.9˚C 0.20˚C
R 0.0˚ to +1780˚C ±2.0˚C 0.40˚C
S 0.0˚ to +1780˚C ±2.0˚C 0.40˚C
B +350˚ to +1820˚C ±2.0˚C 0.50˚C
N -100˚ to +1300˚C ±0.6˚C 0.15˚C
-200˚ to -100˚C ±0.9˚C 0.20˚C
Temperature Units: ˚C, ˚F, ˚K, ˚R, and mV
Fault Detection: Open thermocouple may be detected by software query
Cold Junction Sensors: One for every 8 input channels
Linearization: Performed by lookup table; includes support for storing up to 2
user-defined linearization tables in NVRAM
AC/DC Voltage Specifications:
Range/Resolution:
Range6Resolution
±100 mV 3.05 µV/bit
±1V 30.5 µV/bit
±5V 153 µV/bit
±10V 306 µV/bit
Accuracy: ±0.02% of range7, 10
MultiScan/1200 ——
TempScan/1100
Expansion Boards
Scanning Module Compatibility Guide
MTC/24 MHV/24 TempTC/32B TempRTD/16B TempV/32B
1. Specified for coupling impedance > 30M Ohm and common mode frequency
< 60 Hz
2. 300 VDC or AC peak before equipment damage occurs
3. 18˚ to 28˚C, 1 year; includes cold junction compensation
4. Typical; excludes thermocouple errors
5. Add ±5˚C for common mode voltages greater than 25 VAC
6. Maximum peak-to-peak signal for AC volts
7. For AC voltages where the frequency of the input signal is an integer multiple
of the AC line cycle ±1%
8. 700 VDC or AC peak before equipment damage occurs
9. 325 VDC or AC peak if used in the same system with the MTC/24 scanning
module
10. With line cycle integration enabled
11. Contact factory for availability of higher voltage card
TempScan/1100 Scanning-Module Specifications
TempTC/32B — Thermocouple Scanning Module
Number of Channels: 32 differential; programmable by channel for specific
thermocouple type or a millivolt input
Input Types: J, K, T, E, N, R, S, B, N14, & N28, custom thermocouple, & millivolts
Input Connectors: Screw terminal
Thermocouple Wire: #16 AWG max, #24 AWG min
#20 AWG recommended for type J, K, T, E, and N
#24 AWG recommended for type R, S, and B
Temperature Range & Accuracy:
Type Range Accuracy* Resolution**
J -200˚ to +760˚C ±0.5˚C 0.10˚C
K -200˚ to +1372˚C ±0.5˚C 0.10˚C
T -200˚ to +400˚C ±0.5˚C 0.10˚C
E -200˚ to +1000˚C ±0.5˚C 0.10˚C
N -200˚ to +1300˚C ±0.5˚C 0.10˚C
R 0.0˚ to +1768˚C ±1.0˚C 0.10˚C
S 0.0˚ to +1768˚C ±1.0˚C 0.10˚C
B +350˚ to +1820˚C ±1.0˚C 0.10˚C
N14 0.0˚ to +1300˚C ±0.5˚C 0.10˚C
N28 -270˚ to +400˚C ±0.5˚C 0.10˚C
* 18˚ to 28˚C, 1 year; includes cold junction compensation; excludes thermocouple errors;
thermocouple readings based on NIST Monograph 175
** Typical
Temperature Units: ˚C, ˚F, ˚K, ˚R, and mV
Fault Detection: Open T/C may be detected by software query
Cold Junction Sensors: One for every 8 input channels
Linearization: Performed by lookup table; support included for storing up to two
user-defined linearization tables in NVRAM
Input Impedance: 1M Ohm typ
Input Bias Current: 20 nA max
Maximum Allowable Input: ±35V peak
Channel-to-Digital Low Isolation: 500V max
Channel-to-Channel Isolation: ±10V peak
Channel-to-Channel Cross Talk: 100 dB min
Temperature Coefficient: 0.03 ˚C/˚C
Digital Filtering: Averages 16 samples at 50/60 Hz for line cycle noise rejection
Voltage Range/Resolution: ±100 mV/3.05 µV
Voltage Accuracy: ±0.02%
Voltage Units: Volts, counts
TempRTD/16B — RTD Scanning Module
Number of Inputs: 16 (3- or 4-wire)
Alpha: 0.00385
Input Connectors: Screw terminal
Temperature Range & Accuracy:
Type Range Accuracy Resolution
100 Ohm platinum -100˚C to +630˚C ±0.2˚C 0.1˚C
-270˚C to -100˚C ±0.4˚C 0.2˚C
Excitation Current: <1 mA peak
Temperature Coefficient: <0.1%/˚C
Temperature Units: ˚C, ˚F, ˚K, ˚R, and counts
Linearization: Performed by lookup table; support included for storing user-
defined linearization tables in NVRAM
TempV/32B —Voltage Scanning Module
Number of Inputs: 32 differential
Input Connectors: Screw terminal
Range/Resolution:
Range Resolution
±100 mV 3.05 µV/bit
±1V 30.5 µV/bit
±5V 153 µV/bit
±10V 306 µV/bit
QUICK FIND
tel: 440-439-4091 fax: 440-439-4093 224 sales@iotech.com www.iotech.com
the smart approach to instrumentation
®
Temperature & Voltage Scanning Instruments
CA-35-1, TempScan/1100 or
MultiScan/1200 master/slave
interface cable, 1 ft. (included
with Exp/10A and Exp/11A
at no additional charge)
CA-47, PC/XT/AT, RS-232/422
serial port to TempScan/1100,
MultiScan/1200 or
ChartScan/1400 cable, 6 ft.
MHV/24—High Voltage Scanning Module
Number of Inputs: 24 differential; programmable by channel for any input range
Input Connectors: Screw terminal
Range/Resolution:
Range6Resolution
±2.5V 78.14 µV/bit
±25V 781.4 µV/bit
±250V 7.81 mV/bit
Accuracy: ±0.02% of range7, 10
Digital Filtering: Averages 32 samples at 50/60 Hz for line-cycle noise rejection
(DCV measurements)
Temperature Coefficient: <0.01%/˚C
Input Impedance: 10M Ohm
Input Bias Current: 20 pA max
Maximum Common Mode Voltage 1, 8, 9: 500 VDC or AC peak
Maximum Normal Mode Voltage: 500 VDC or AC peak
Common Mode Rejection: 100 dB typ
Maximum Allowable Input: 400 VDC
Channel-to-Power Ground Isolation: 500V peak
Channel-to-Channel Isolation: 500V peak9
Ordering Information
TempScan/1100
Description Part No.
High-speed temperature measurement system, includes
IEEE 488* & RS-232/422 interfaces; ChartView & DIAdem®-View
Windows® applications; DB50 digital I/O port
mating connector; and rack-mount kit TempScan/1100**
32-channel thermocouple scanning
module for the TempScan/1100 TempTC/32B
32-channel voltage scanning
module for the TempScan/1100 TempV/32B
16-channel RTD scanning
module for the TempScan/1100 TempRTD/16B
1 Mbyte memory option for the TempScan/1100 TempMEM1
4 Mbyte memory option for the TempScan/1100 TempMEM4
8 Mbyte memory option for the TempScan/1100 TempMEM8
MultiScan/1200
High-speed isolated temperature and voltage measurement
instrument, includes IEEE 488* and RS-232/422 interfaces;
ChartView & DIAdem-View software; DB50 digital I/O
port mating connector; and rack-mount kit MultiScan/1200
24-channel thermocouple/volts scanning
module for the MultiScan/1200 MTC/24
24-channel high-voltage scanning
module for the MultiScan/1200 MHV/24
1 Mbyte memory option for the MultiScan/1200 MultiMEM1
4 Mbyte memory option for the MultiScan/1200 MultiMEM4
8 Mbyte memory option for the MultiScan/1200 MultiMEM8
2-slot expansion chassis, including rack-mount kit and
CA-35-1 master/slave cable Exp/10A
10-slot expansion chassis, including rack-mount kit and
CA-35-1 master/slave cable Exp/11A
Software
Description Part No.
ChartView Plus ChartView Plus
LabVIEW® example VI’s for the TempScan/1100
and the MultiScan/1200†† LBV/DAI
ScanServer™xx, server for SCADA/HMI applications ScanServer
Note: The full range of software support is discussed on p. 227.
Cables
PC/AT/XT serial port (9- and 25-pin sub D)
to TempScan/1100 or MultiScan/1200
(9-pin sub D) RS-232/422 cable, 6 ft. CA-47
Shielded IEEE 488 cable, 6 ft. CA-7-3
Related Products
Hardware
Net232 p. 225
Personal488/PCI p. 265
Personal488/ATpnp p. 266
Personal488/AT p. 267
Personal488 p. 268
Personal488/CARD p. 269
Software
DIAdem p. 198
ChartView p. 228
ChartViewNET p. 228
Note: Buy your thermocouples direct from IOtech. See p. 301 for an overview
of the various thermocouple types offered.
TempScan/1100
& MultiScan/1200
Specifications & Ordering Information
(Refer to previous page for numbered references 1, 7, 8, 9, 10)
* A Personal488 series product is required for IEEE 488 operation of
TempScan/1100 or MultiScan/1200 with ChartView software
** TempTC/32B, TempV/32B, and TempRTD/16B scanning modules must be
ordered separately
MTC/24, and MHV/24 scanning modules must be ordered separately
†† IEEE 488 interface support only; contact factory for RS-232 support
xx Contact factory for availability