FKH Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter, Fuseholder 1-pole, Line Switch 2-pole Screw-on mounting from front side Standard version Aluminum Nickel plated steel C14 See below: Approvals and Compliances 70 C Description - Panel mount : Screw-on mounting from front side - 4 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1pole , Line-filter in standard version - Quick connect terminals 6.3 x 0.8 mm Characteristics - Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Medical version M80 References Alternative: version with 2-stage filter FKHD Weblinks pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 250 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21 acc. to IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Fuseholder Rated Power Acceptance @ Ta 23 C Power Acceptance @ Ta > 23C Line Switch Line Filter MTBF C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 10 A, Protection Class I 1-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 1.6 W (1 pole) Admissible power acceptance at higher ambient temperature see derating curves 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'700'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products 1 FKH Power Entry Modules with Line Filter https://www.schurter.com /PG06 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FKH Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40004665 UL Approvals UL UL File Number: E72928 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. White paper Glow wire test SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 &-13. Medical Technology SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products FKH Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] Case 45 40 0.15 +0.5 61-0.2 R1 60.4 6.3x0.8 o 6.3x90 49 o 3.2 63 65 0.5 40 M3 3.5 28 R4 50 0.5 29.50.5 14 5.5 61.3 28.7 67 Case 50 49.5 +0.5 61-0.2 o 6.3x90 60.4 6.3x0.8 40 0.15 o 3.2 63 65 0.5 40 M3 3.5 28 R4 50 0.5 15 5.5 40.5 29.50.5 28.7 55 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 1 Standard Version 2 x 10 68 2.2 1 2 Standard Version 2x4 68 2.2 1 4 Standard Version 2 x 1.5 68 2.2 1 6 Standard Version 2 x 0.8 68 2.2 1 10 Standard Version 2 x 0.3 68 2.2 1 1 Medical Version (M5) 2 x 10 68 - 1 2 Medical Version (M5) 2x4 68 - 1 4 Medical Version (M5) 2 x 1.5 68 - 1 6 Medical Version (M5) 2 x 0.8 68 - 1 10 Medical Version (M5) 2 x 0.3 68 - 1 EMC Products 3 FKH Power Entry Modules with Line Filter https://www.schurter.com /PG06 Diagrams Standard version Medical version (M5) N N' L1 1) PE Cy R Cx F1 L L2 Cx Cy PE' 2) N 1) PE L' L R = 1M 1) Line 2) Load N' L1 R F1 Cx L2 Cx PE' 2) L' 1) Line 2) Load Derating Curves 1-pole Admissible power acceptance in Watt 1.6 1.4 1.2 I = 1.0 In 1.0 0.8 I = 0.7 In 0.6 I = << In 0.4 0.2 0.0 0 20 40 60 80 100 Ambient air temperature Ta C Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 1A 2A 10 A 4 EMC Products 4A 6A FKH Power Entry Modules with Line Filter https://www.schurter.com /PG06 Medical version (M5) 1A 2A 4A 6A 10 A All Variants Type Rated Current [A] FKH 1 FKH 2 FKH FKH Filter-Type Fuseholder Line Switch Housings Material: Housing Order Number Standard Version 1-pole 2-pole Standard Version 1-pole 2-pole 45 Aluminum 4304.4041 45 Aluminum 4304.4042 4 Standard Version 1-pole 6 Standard Version 1-pole 2-pole 45 Aluminum 4304.4043 2-pole 45 Aluminum FKH 10 Standard Version 4304.4044 1-pole 2-pole 45 Aluminum FKH 1 4304.4045 Medical Version (M5) 1-pole 2-pole 45 Aluminum FKH 4304.4046 2 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4047 FKH 4 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4048 FKH 6 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4049 FKH 10 Medical Version (M5) 1-pole 2-pole 45 Aluminum 4304.4050 FKH 1 Standard Version 1-pole 2-pole 50 Nickel plated steel 4304.4001 FKH 2 Standard Version 1-pole 2-pole 50 Nickel plated steel 4304.4002 FKH 4 Standard Version 1-pole 2-pole 50 Nickel plated steel 4304.4003 FKH 6 Standard Version 1-pole 2-pole 50 Nickel plated steel 4304.4004 FKH 10 Standard Version 1-pole 2-pole 50 Nickel plated steel 4304.4005 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Accessories Description Assorted Covers Rear Cover 0859.0074 EMC Products 5 FKH Power Entry Modules with Line Filter https://www.schurter.com /PG06 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I 4787 4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to FKH Connector Overview complete 4022 4782 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4012 Mounting: Power Supply Cord, 3 x 1 mm, Screw clamps, Connector: IEC C13 4012 4785 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 Connector further types to FKH ... 30.05.2019 4022 Mounting: Power Supply Cord, 3 x 1.5 mm, Screw clamps, Connector: IEC C13 6 EMC Products The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.