RE17LCBM Product datasheet Characteristics Main Range of product Zelio Time Product or component type Modular timing relay Discrete output type Solid state Width 17.5 mm Component name RE17L Time delay type C Time delay range 1...10 h 1...10 min 10...100 h 1...10 s 6...60 min 6...60 s 0.1...1 s Nominal output current 0.7 A Complementary Control type Selector switch on front panel [Us] rated supply voltage 24...240 V AC at 50/60 Hz Voltage range 0.85...1.1 Us Supply frequency 50...60 Hz (+/- 5 %) Release of input voltage 7V Control signal pulse width 0.05 s typical Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 [Uimp] rated impulse withstand voltage 5 kV (1.2/50 s) Power on delay < 100 ms Connections - terminals Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm AWG 20...AWG 12 (solid) without cable end Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm AWG 20...AWG 14 (solid) without cable end Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm AWG 24...AWG 14 (flexible) with cable end Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm AWG 24...AWG 16 (flexible) with cable end Jul 11, 2019 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications off-delay timing relay - control - 1 s..100 h 24..240 V - solid state output Tightening torque 0.6...1 N.m conforming to IEC 60947-1 Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 Housing material Self-extinguishing Repeat accuracy +/- 0.5 % conforming to IEC 61812-1 Temperature drift +/- 0.05 %/C Voltage drift +/- 0.2 %/V Setting accuracy of time delay +/- 10 % of full scale at 25 C conforming to IEC 61812-1 Reset time 350 ms on de-energisation typical On-load factor 100 % Power consumption in VA 0...3 VA at 240 V AC Power consumption in W <= 1.5 W at 240 V DC Breaking capacity 0.5 A AC/DC conforming to UL 0.7 A AC/DC at 20 C Operating frequency 10 Hz Maximum output current 20 A <= 10 ms Minimum switching current 10 mA Leakage current < 5 mA Maximum switching voltage 250 V AC Voltage drop 4 V 3-wire 8 V 2-wire Electrical durability 100000000 cycles Marking CE Creepage distance 4 kV/3 conforming to IEC 60664-1 Safety reliability data MTTFd = 353.8 years B10d = 320000 Mounting position Any position in relation to normal vertical mounting plane Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Product weight 0.068 kg Environment Immunity to microbreaks <= 20 ms Derating factor 5 mA/C Standards EN 61000-6-1 EN 61000-6-2 2004/108/EC EN 61000-6-3 2006/95/EC IEC 61812-1 EN 61000-6-4 Product certifications CSA GL cULus Ambient air temperature for storage -30...60 C Ambient air temperature for operation -20...60 C IP degree of protection IP20 (terminal block) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 Vibration resistance 20 m/s (f = 10...150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 Relative humidity 93 % without condensation conforming to IEC 60068-2-30 Electromagnetic compatibility Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3 Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3 Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3 Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC 61000-4-4 level 3 Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 3 1.2/50 s shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 3 1.2/50 s shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3 2 Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3 Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11 Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11 Conducted and radiated emissions conforming to EN 55022 class B Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1650 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available End of Life Information Product end of life instructions Available 3 Product datasheet Dimensions Drawings Width 17.5 mm 4 RE17LCBM Product datasheet Connections and Schema RE17LCBM Internal Wiring Diagram 5 Product datasheet Connections and Schema Wiring Diagram 6 RE17LCBM Product datasheet Technical Description RE17LCBM Function C : Off-Delay Relay with Control Signal Description After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 7 Product datasheet Technical Description RE17LCBM Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/R2 2 timed outputs R2 inst. The second output is instantaneous if the right position is selected T Timing period Ta Adjustable On-delay Tr Adjustable Off-delay U Supply 8