Inductive Proximity Sensors Bulletin 802PR Limit Switch Style Description Features Styles Bulletin 802PR inductive proximity sensors are self-contained, 2-wire devices designed to detect the presence of ferrous and nonferrous metal objects without touching them. Types LA and XA are high-output AC models designed to switch current loads up to 1 A, while types LB and XB are AC/DC solid-state switches made to interface directly with programmable controllers.E S Multiple sensing directions AC/DC 2-Wire . . . . . . . . . . . page 2-150 Each sensor is housed in a self-extinguishing glass-reinforced polyester body. Special hazardous location models are available which meet Division 2 enclosure standards in Classes I, II, and III (see specifications). Switch constructions include top and side sensing models. The side-sensing head can be rotated in 90-degree increments to sense in four directions. These devices are available with a threaded conduit opening, conduit coupler, 3-pin mini connector, 3-pin micro connector, or pre-wired cable. S Cable, conduit, or quick-disconnect styles S Short circuit protection (AC/DC models) S Overload protection (AC/DC models) S Transient noise protection Hazardous Location AC/DC 2-Wire . . . . . . . . . . . page 2-155 AC 2-Wire High-Output . . . page 2-157 Hazardous Location AC 2-Wire High-Output . . . . . . page 2-161 S False pulse protection Accessories S Hazardous location models are available Quick-Disconnect Cables . . . page 5-1 S UL listed, CSA certified, and CE marked for all applicable directives General Information Metric/English Conversion Chart . . . . . . . . . page 11-1 E High-output models should not be used in solid-state switching, TTL, or programmable controller operations. 2-149 Inductive Proximity Sensors 802PR 2-Wire AC/DC Limit Switch Style Specifications Load Current Leakage Current Operating Voltage 802PR AC/DC Cable Style page 2-151 AC 4-25mA; DC 2-25mA 1.7mA at 132V, 2.5mA at 250V 20-250V AC/DC Voltage Drop 10V Repeatability 10% typical Hysteresis 10% typical Transient Noise Protection Incorporated Short Circuit Protection Incorporated Overload Protection Incorporated False Pulse Protection Incorporated Radio Frequency Protection 10V per meter; Frequency range 20-1000 MHz Approvals UL listed, CSA certified, and CE marked for all applicable directives Enclosure NEMA 1, 2, 3, 4, 4XE, 12, 13, IP65 (IEC 529) Self extinguishing glass-reinforced polyester body Connections 802PR AC/DC Mini Quick-Disconnect Style page 2-152 LEDs Operating Temperature Shock Vibration Cable: 2.4m (8ft) length 2-conductor ToughLink Quick-Disconnect: 3-pin micro style 3-pin mini style Conduit Opening or Conduit Coupler: Internal thread with screw terminals (use #18-14 AWG wire) Green: Power; Red: Output energized (both on in SCP/Overload) -25C to +75C (-13F to +167F) 30g, 11ms 55Hz, 1mm amplitude, 3 planes E Corrosion resistant models 802PR AC/DC Micro Quick-Disconnect Style page 2-153 Features S 2-wire operation S 2-conductor or 3-pin connection S 20-250V AC/DC (for solid state inputs) S Normally open output S Short circuit, overload, false pulse, RFI and transient noise protection 802PR AC/DC Conduit Style page 2-154 2-150 S Corrosion resistant models S 2 LEDs S UL listed, CSA certified, and CE marked for all applicable directives Correction Factors Target Material Correction Factor Steel 1.0 Stainless Steel 0.9 Brass 0.8 Aluminum 0.75 Copper 0.7 Inductive Proximity Sensors 802PR 2-Wire AC/DC, Cable Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Switching Frequency (Hz) Cable Length m (ft) Corrosion Resistant Catalog Number Cable Style Y 802PR-XBAM1-08 N 802PR-LBAM1-08 Y 802PR-XBAM1-12 N 802PR-LBAM1-12 Y 802PR-XBAR1-08 N 802PR-LBAR1-08 Y 802PR-XBAR1-12 N 802PR-LBAR1-12 2 5 (8) 2.5 Side 17 (0 (0.67) 67) Y NO N.O. 20 3 6 (12) 3.6 2 5 (8) 2.5 Top 17 (0 (0.67) 67) Y NO N.O. 20 3 6 (12) 3.6 Accessories Description Page Number Terminal Chambers 5-19 Dimensions--mm (inches) 41.0 (1.63) 6.0 (0.23) Dia. Holes 41.0 (1.63) 26.0 (1.02) LEDs 42.0 (1.66) Front Mounting U.S. (1 5/32in x 2 11/32 in) DIN 30 x 60 6.0 (0.23) Front Mounting Hole 60.0 Pattern (2.34) Front View Two Holes for #10 or M5 Screws 30.0 (1.16) 109.0 (4.34) 117.0 (4.63) Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep 60.0 (2.34) (LB Version only) 2.4m (8ft) 30.0 (1.16) Note: Side sensing model heads can be turned in 90 increments to accommodate 4 side sensing positions. Wiring Diagram Normally Open White Black Load Note: Load can be switched to white lead. 2-151 Inductive Proximity Sensors 802PR 2-Wire AC/DC, Mini Quick-Disconnect Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Switching Frequency (Hz) 17 (0 (0.67) 67) Y NO N.O. 20 Catalog Number Mini QD Style 802PR-LBAE1 Side 802PR-LBAK1 Top Recommended Standard QD Cordset Required (-6F = 1.8m (6ft)) 889N-F3AFC-6F QD Cordsets and Accessories Description Page Number Other Cordsets Available 5-8 Terminal Chambers 5-19 Dimensions--mm (inches) 41.0 (1.63) 6.0 (0.23) Dia. Holes 41.0 (1.63) 26.0 (1.02) LEDs 42.0 (1.66) Front Mounting U.S. (1 5/32in x 2 11/32in) DIN 30 x 60 Front Mounting Hole 60.0 Pattern (2.34) Front View Two Holes for #10 or M5 Screws 30.0 (1.16) 6.0 (0.23) 109.0 (4.34) 131.0 (5.16) 7/8-16UN Note: Side sensing model heads can be turned in 90_ increments to accommodate 4 side sensing positions. Wiring Diagram Normally Open 1 2 3 Load Note: Load can be switched to Pin 3. 2-152 Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep 30.0 (1.16) 60.0 (2.34) Inductive Proximity Sensors 802PR 2-Wire AC/DC, Micro Quick-Disconnect Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Switching Frequency (Hz) 17 (0 (0.67) 67) Y NO N.O. 20 Catalog Number Micro QD Style 802PR-LBAC1 Side 802PR-LBAF1 Top Recommended Standard QD Cordset Required (-2 = 2m (6.5ft)) 889R-F3ACA-2 QD Cordsets and Accessories Description Page Number Other Cordsets Available 5-8 Terminal Chambers 5-19 Dimensions--mm (inches) 41.0 (1.63) 6.0 (0.23) Dia. Holes 41.0 (1.63) 26.0 (1.02) LEDs 42.0 (1.66) Front Mounting U.S. (1 5/32 in. x 2 11/32 in.) DIN 30 x 60 Front Mounting Hole 60.0 Pattern (2.34) Front View Two Holes for #10 or M5 Screws 30.0 (1.16) 6.0 (0.23) 109.0 (4.34) 131.0 (5.16) 1/2-20UNF-2A Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep 60.0 (2.34) 30.0 (1.16) Note: Side sensing model heads can be turned in 90_ increments to accommodate 4 side sensing positions. Wiring Diagram Normally Open Load 3 2 1 Note: Load can be switched to pin 2. 2-153 Inductive Proximity Sensors 802PR 2-Wire AC/DC, Conduit Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Switching Frequency (Hz) Corrosion Resistant Connection Type Catalog Number Conduit Style Y N Side ide 17 (0.67) Y N.O. 20 802PR-XBAB1 1/2 14NPT 1/2-14NPT 802PR-LBAB1 Y N N 802PR-XBAB1-S6 ISO 20-1.5 20 1 5 802PR-LBAB1-S6 Conduit Coupler 802PR-LBAA1 Y N Top To 17 (0.67) Y N.O. 20 802PR-XBAH1 1/2 14NPT 1/2-14NPT 802PR-LBAH1 Y N N 802PR-XBAH1-S6 ISO 20-1.5 20 1 5 802PR-LBAH1-S6 Conduit Coupler 802PR-LBAJ1 Dimensions--mm (inches) 41.0 (1.63) 41.0 (1.63) 26.0 (1.02) 6.0 (0.23) Dia. Holes Front Mounting U.S. (1 5/32 in. x 2 11/32 in.) DIN 30 x 60 Front Mounting Hole 60.0 Pattern (2.34) Front View Two Holes for #10 or M5 Screws LEDs 42.0 (1.66) 30.0 (1.16) 6.0 (0.23) 1/2-14 NPTX0.5" Deep or ISO 20-1.5X12.5mm Deep Inside Threads 109.0 (4.34) 117.0 (4.63) Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep (LB Version only) 30.0 (1.16) 16.0 (0.63) Conduit Coupler 1 in. Hub 1/2-14 NPT Inside Threads 16.0 (0.63) Note: Side sensing model heads can be turned in 90_ increments to accommodate 4 side sensing positions. Wiring Diagram Normally Open Terminal 1 Load Terminal 2 Note: Load can be switched to Terminal 1. 2-154 60.0 (2.34) 15.0 (0.59) Inductive Proximity Sensors 802PR 2-Wire AC/DC Hazardous Location Limit Switch Style Specifications Load Current Leakage Current Operating Voltage 802PR AC/DC Conduit Style page 2-156 10V 10% typical Hysteresis 10% typical Transient Noise Protection Incorporated Short Circuit Protection Incorporated Overload Protection Incorporated False Pulse Protection Incorporated UL listed, CSA certified, and Factory Mutual approved Enclosure NEMA 1, 2, 3, 4, 12, 13 IP65 (IEC 529) Division 2 Class I: Groups A, B, C & D; Class II: Groups F & G; Class III: All groups Self-extinguishing glass-reinforced polyester body S 2-wire operation S 2-terminal connection S 20-250V AC/DC (for solid state inputs) 10V per meter Frequency range 20-1000 MHz Approvals Features Connection LEDs S Normally open output S Short circuit, overload, false pulse, RFI, and transient noise protection 20-250V AC/DC Repeatability DC: 2-25mA 1.7mA at 132V, 2.5mA at 250V Voltage Drop Radio Frequency Protection AC: 4-25mA Operating Temperature Shock S Hazardous location rating Vibration Conduit Coupler: 1/2-14 NPT internal thread with screw terminals use (#18-14 AWG wire) Green: Power Red: Output energized (both on in SCP/Overload) -25C to +75C (-13F to +167F) 30g, 11ms 55Hz, 1mm amplitude, 3 planes S 2 LEDs S UL listed, CSA certified, and Factory Mutual approved Correction Factors Target Material Correction Factor Steel 1.0 Stainless Steel 0.9 Brass 0.8 Aluminum 0.75 Copper 0.7 2-155 Inductive Proximity Sensors 802PR 2-Wire AC/DC Hazardous Location, Conduit Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Switching Frequency (Hz) 17 (0 (0.67) 67) Y NO N.O. 20 Catalog Number Conduit Style Side 802PR-LBAA3 Top 802PR-LBAJ3 Dimensions--mm (inches) 41.0 (1.61) 6.0 (0.24) Dia. Holes 41.0 (1.61) 26.0 (1.02) Front Mounting Hole 60.0 Pattern (2.36) Front View Two Holes for #10 or M5 Screws LEDs Front Mounting U.S. (1 5/32" x 2 11/32") DIN 30 x 60 42.0 (1.65) 30.0 (1.18) 6.0 (0.24) 109.0 (4.29) Conduit Coupler 1in Hub 1/2-14 NPT Inside Threads 16.0 (0.63) 124.0 (4.88) 15.0 (0.59) Note: Side-sensing model heads can be turned in 90_ increments to accommodate 4 side-sensing positions. Wiring Diagram Terminal 1 Load Terminal 2 Note: Load can be switched to Terminal 1. 2-156 Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (.375) Deep 30.0 (1.18) 60.0 (2.36) Inductive Proximity Sensors 802PR 2-Wire AC High Output Limit Switch Style Specifications Load Current Inrush Current Supply Current (minimum) Leakage Current Operating Voltage 802PR AC Cable Style page 2-158 1A at +40C linearly derated to 0.5A at 75C 10A/1s 25mA 3.5mA (60-132V AC); 6.5mA (102-132V AC) 60-132V AC or 102-132V AC Voltage Drop 8.5V Repeatability 0.025mm Hysteresis 15% (max.) False Pulse Protection Incorporated Transient Noise Protection Incorporated Approvals UL listed, CSA certified, and CE marked for all applicable directives Enclosure NEMA 1, 2, 3, 4, 4XE, 12, 13, IP65 (IEC 529) Self-extinguishing glass-reinforced polyester body Connections 802PR AC Mini Quick-Disconnect Style page 2-159 LED Operating Temperature Shock Vibration Cable: 8ft or 12ft length 2-conductor 16 AWG STO (oil-resistant thermoplastic) Quick Disconnect: 3-pin mini style Conduit Opening or Conduit Coupler:1/2-14NPT internal thread with screw terminals (use #18-14 AWG wire) Red: Output Energized -25C to +75C (-13F to +167F) 30g, 11ms 55Hz, 1mm amplitude, 3 planes E Corrosion resistant models 802PR AC Conduit Style page 2-160 Features Correction Factors Target Material Correction Factor Steel 1.0 Stainless Steel 0.80-0.85 Brass 0.50-0.55 Aluminum 0.45-0.50 Copper 0.40-0.45 S 2-wire operation S 2-conductor, 3-pin, or 2-terminal connection S 60-132V AC or 102-132V AC S Normally open or N.O./N.C. selectable output S High output (1A) S Transient noise and false pulse protection S UL listed, CSA certified, and CE marked for all applicable directives 2-157 Inductive Proximity Sensors 802PR 2-Wire AC High Output, Cable Style Limit Switch Style Selection Guide Nominal Sensing Distance mm (inches) Sensing Direction Voltage Range Shielded Output Configuration Corrosion Resistant Switching Frequency (Hz) Cable Length (Ft) Catalog Number Cable Style Side 8 802PR-LABM2-08 12 802PR-LABM2-12 8 802PR-LABR2-08 Select bleE SelectableE Top 20 60 132V AC 60-132V Side N Select bleE SelectableE Top 13 (0.51) Y 12 802PR-LABR2-12 8 802PR-LACM2-08 12 802PR-LACM2-12 8 802PR-LACR2-08 12 802PR-LACR2-12 Side Top 102 132V AC 102-132V NO N.O. 16 Side Y Top 8 802PR-LAAM1-08 12 802PR-LAAM1-12 8 802PR-LAAR1-08 12 802PR-LAAR1-12 8 802PR-XAAM1-08 12 802PR-XAAM1-12 8 802PR-XAAR1-08 12 802PR-XAAR1-12 E Preset to N.O. at factory. E Preset to N.C. at factory. Dimensions--mm (inches) 41.0 (1.63) 26.0 (1.02) 6.0 (0.23) Dia. holes 41.0 (1.63) Front Mounting Hole Pattern Front View Two Holes for #10 or M5 Screws LEDs 60.0 (2.34) 42.0 (1.66) Front Mounting U.S. (1 5/32in x 2 11/32in) DIN 30 x 60 30.0 (1.16) 6.0 (0.23) 109.0 (4.34) Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep (LA Version Only) 117.0 (4.63) 2.4m (8ft) or 3.7m (12ft) 60.0 (2.34) 30.0 (1.16) Note 1: Side sensing model heads can be turned in 90 increments to accommodate 4 side sensing positions. Note 2: Low voltage models have 2 LEDs. Wiring Diagrams Accessories Normally Open Normally Closed White Black White Load Note: Load can be switched to white lead. 2-158 Black Description Terminal Chambers Load Page Number 5-19 Inductive Proximity Sensors 802PR 2-Wire AC High Output, Mini Quick-Disconnect Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Voltage Range Switching Frequency (Hz) Catalog Number Mini QD Style Side 802PR-LABE2 Select bleE SelectableE Top 802PR-LABK2 60 132V AC 60-132V Side 13 (0 (0.51) 51) Top Y 20 802PR-LACE2 Select bleE SelectableE 802PR-LACK2 Side 802PR-LAAE1 NO N.O. Top 102 132V AC 102-132V 16 802PR-LAAK1 Recommended Standard QD Cordset Required (-6F = 1.8m (6ft)) 889N-F3AFC-6F E Preset to N.O. at factory. E Preset to N.C. at factory. QD Cordsets and Accessories Description Wiring Diagram Normally Open or Normally Closed Page Number Other Cordsets Available 5-8 Terminal Chambers 5-19 1 2 3 Load Note: Load can be switched to pin 3. Dimensions--mm (inches) 41.0 (1.63) 6.0 (0.23) Dia. Holes Front Mounting Hole Pattern Front View Two Holes for #10 or M5 Screws 41.0 (1.63) 26.0 (1.02) LED 42.0 (1.66) Front Mounting U.S. (1 5/32in x 2 11/32in) DIN 30 x 60 6.0 (0.23) Pre-Wired Receptacle, 3-Pin Mini Style 60.0 (2.34) 109.0 (4.34) 30.0 (1.16) Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep 131.0 (5.16) 60.0 (2.34) (LA Version Only) 30.0 (1.16) 7/8-16UN-2A Note 1: Side sensing model heads can be turned in 90_ increments to accommodate 4 side sensing positions. Note 2: Low voltage models have 2 LEDs. 2-159 Inductive Proximity Sensors 802PR 2-Wire AC High Output, Conduit Style Limit Switch Style Selection Guide Nominal Sensing Distance mm (inches) Sensing Direction Shielded Output Configuration Corrosion Resistant Voltage Range Switching Freq. (Hz) Side Select bleE SelectableE Top 60 132V AC 60-132V 20 Side Select bleE SelectableE Top 13 (0 (0.51) 51) N Y Side Top NO N.O. 102 132V AC 102-132V 16 Side Y Top Connection Catalog Number Conduit Style Conduit Coupler 802PR-LABA2 Threaded 1/2"-14 NPTI 802PR-LABB2 Conduit Coupler 802PR-LABJ2 Threaded 1/2"-14 NPTI 802PR-LABH2 Conduit Coupler 802PR-LACA2 Threaded 1/2"-14 NPTI 802PR-LACB2 Conduit Coupler 802PR-LACJ2 Threaded 1/2"-14 NPTI 802PR-LACH2 Conduit Coupler 802PR-LAAA1 Threaded 1/2"-14 NPTI 802PR-LAAB1 Conduit Coupler 802PR-LAAJ1 Threaded 1/2"-14 NPTI 802PR-LAAH1 Threaded 1/2"-14 NPTI 802PR-XAAB1 Threaded 1/2"-14 NPTI 802PR-XAAH1 E Preset to N.O. at factory. E Preset to N.C. at factory. I To order ISO 20-1.5 add `-S6' to catalog number. Dimensions--mm (inches) 41.0 (1.63) 6.0 (0.23) Dia. Holes LED 41.0 (1.63) 26.0 (1.02) Front Mounting U.S. (1 5/32 in. X 2 11/32 in.) DIN 30 x 60 Front Mounting Hole Pattern Front View Two Holes for #10 or M5 Screws 42.0 (1.66) 60.0 (2.34) 30.0 (1.16) 6.0 (0.23) 1/2-14 NPT or ISO 20-1.5 Inside Threads 109.0 (4.34) Threaded Conduit Opening 16.0 (0.63) Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.38) Deep 117.0 (4.63) (LA Version Only) Conduit Coupler 1in HUB 1/2-14 NPT Inside Threads 15.0 (0.59) 16.0 (0.63) Note 1: Side sensing model heads can be turned in 90 increments to accommodate 4 side sensing positions. Note 2: Low voltage models have 2 LEDs. Wiring Diagram Normally Open Terminal 1 Normally Closed Load Terminal 1 Terminal 2 Note: Load can be switched to Terminal 1. 2-160 Load Terminal 2 60.0 (2.34) 30.0 (1.16) Inductive Proximity Sensors 802PR 2-Wire AC Hazardous Location, High Output Limit Switch Style Specifications Load Current 10A/1s Supply Current 25mA min. Leakage Current Operating Voltage 802PR AC Conduit Style page 2-162 8.5V .025mm Hysteresis 15% maximum False Pulse Protection Incorporated Transient Noise Protection Incorporated S 2-wire operation Approvals UL listed, CSA certified, and FM approved Enclosure NEMA 1, 2, 3, 4, 12, 13 IP65 (IEC 529) Division 2 Class I: Groups A, B, C & D; Class II: Groups F & G; Class III: All groups Self-extinguishing glass reinforced polyester body Connection S 2-terminal connection S 102-132V AC LED Operating Temperature Shock S High output (1A) Vibration S Normally open output S UL listed, CSA certified, and Factory Mutual approved 102-132V AC Repeatability Features S Transient noise and false pulse protection 6.5mA Voltage Drop S Hazardous location rating 1A at +40C linearly derated to 0.5A at 75C Inrush Current Conduit Coupler: 1/2-14 NPT internal thread with screw terminals use (#18-14 AWG wire) Red: Output Energized -25C to +75C (-13F to +167F) 30g, 11ms 55Hz, 1mm amplitude, 3 planes Correction Factors Target Material Correction Factor Steel 1.0 Stainless Steel 0.80-0.85 Brass 0.50-0.55 Aluminum 0.45-0.50 Copper 0.40-0.45 2-161 Inductive Proximity Sensors 802PR 2-Wire AC Hazardous Location, High Output, Conduit Style Limit Switch Style Selection Guide Sensing Direction Nominal Sensing Distance mm (inches) Shielded Output Configuration Switching Frequency (Hz) 13 (0 (0.51) 51) Y NO N.O. 16 Side Catalog Number Conduit Style 802PR-LAAA3 Top 802PR-LAAJ3 Dimensions--mm (inches) 41.3 (1.63) 5.9 (0.23) Dia. Holes 41.3 (1.63) 25.8 (1.02) LED 42.1 (1.66) Front Mounting U.S. (1 5/32 in. x 2 11/32 in.) DIN 30 x 60 5.9 (0.23) Conduit Coupler 1in Hub 1/2-14 NPT Inside Threads 110.3 (4.34) 16.0 (0.63) 15.0 (0.59) Note: Side sensing model heads can be turned in 90_ increments to accommodate 4 side sensing positions. Wiring Diagram Normally Open Terminal 1 Terminal 2 Load Note: Load can be switched to Terminal 1. 2-162 Front Mounting Hole Pattern Front View Two Holes for #10 or M5 Screws 59.5 (2.34) 29.4 (1.16) Rear Mounting Hole Pattern Front View Two #10-32 Tapped Holes 9.5 (0.375) Deep 59.5 (2.34) 29.4 (1.16)