DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 1 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
10W isolated DC-DC converter with Ultra-wide Input
and Regulated Single Output
RoHS Patent Protection
FEATURES
Ultra-wide 4:1 input voltage range
High efficiency up to 85%
Reinforced I/O isolation test voltage 2.25k VDC
Operating ambient temperature range -40to
+85
Input under-voltage protection, output short
circuit, over-current, over–voltage protection
Low output ripple & noise
EN50121-3-2 & CISPR32/EN55032 CLASS A EMI
compliant without external components
EN50155/EN60950 Approval
Designed to meet UL62368/IEC62368 standard
Input Reverse Polarity Protection available with
Chassis (A2S) or DIN-Rail mounting (A4S) version
Industry standard pin-out
URB1D_LMD-10WR3 series of isolated 10W DC-DC converter products with an ultra-wide 4:1 input voltage and feature efficiencies of up to
85%, input to output isolation is tested with 2250VDC and the converter safely operate ambient temperature of -40 to +85, input
under-voltage protection, output short-circuit, over-voltage, over-current protection and are offered with various mounting options ideally
suiting electronic equipment and railway vehicle applications using 72V, 96V and 110V battery voltages.
Selection Guide
Certification
Part No.
Input Voltage (VDC)
Output
Max.
Capacitive
Load(µF)
Nominal
(Range)
Max.
Voltage (VDC)
Current (mA)
Max./Min.
CE
URB1D03LMD-10WR3
110
(40-160)
170
3.3
2400/0
5400
URB1D05LMD-10WR3
5
2000/0
5400
URB1D12LMD-10WR3
12
833/0
470
URB1D15LMD-10WR3
15
667/0
330
URB1D24LMD-10WR3
24
417/0
100
Note:
Use “H” suffix for heat sink mounting, “A2S” suffix for chassis mounting and “A4S” suffix for DIN-Rail mounting. We recommend to choose modules with a heat
sink for enhanced heat dissipation and applications with extreme temperature requirements;
Absolute maximum stress rating without damage (not recommended);
Efficiency is measured at nominal input voltage and rated output load; efficiencies for A2S and A4S Model’s is decreased by 2% due to the input reverse
polarity protection circuit.
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Input Current (full load /
no-load)
Nominal input voltage
3.3V output
--
95/3
98/8
mA
Others
--
110/3
117/8
Reflected Ripple Current
Nominal input voltage
--
25
--
Surge Voltage (1sec. max.)
-0.7
--
180
VDC
Start-up Voltage
100% load
--
--
40
Shut-down Voltage
28
33
--
Start-up Time
Nominal input voltage & constant resistance load
--
10
--
ms
Input Filter
Pi filter
Hot Plug
Unavailable
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 2 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Voltage Accuracy
0%-100% load
--
±1
±3
%
Linear Regulation
Input voltage variation from low to high at full load
--
±0.2
±0.5
Load Regulation
0%-100% load
--
±0.5
±1
%
Transient Recovery Time
25% load step change,
nominal input voltage
--
300
500
µs
Transient Response Deviation
3.3V/5V output
--
±3
±8
%
Others
--
±3
±5
Temperature Coefficient
Full load
--
±0.02
±0.03
%/
Ripple & Noise
20MHz bandwidth, 5%-100% load
--
50
100
mV p-p
Over-voltage Protection
Input voltage range
110
--
160
%Vo
Over-current Protection
120
--
210
%Io
Short-circuit Protection
Continuous, self-recovery
Note: Ripple & Noise at5% load is 5%Vo max. The ”parallel cable” method is used for Ripple and Noise test, please refer to DC-DC Converter Application
Notes for specific information.
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Isolation
Input-output Electric Strength Test for 1 minute with
a leakage current of 1mA max.
2250
--
--
VDC
Input/output-case Electric Strength Test for 1 minute
with a leakage current of 1mA max.
1600
--
--
Insulation Resistance
Input-output resistance at 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output capacitance at 100KHz/0.1V
--
2200
--
pF
Operating Temperature
See Fig.1
-40
--
+85
Storage Temperature
-55
--
+125
Pin Soldering Resistance
Temperature
Soldering spot is 1.5mm away from case for 10
seconds
--
--
300
Storage Humidity
Non-condensing
5
--
95
%RH
Vibration
IEC61373 - Category 1, Grade B
Switching Frequency
PWM Mode
--
300
--
KHz
MTBF
MIL-HDBK-217F@25
1000
--
--
K hours
Note:Switching frequency is measured at full load. The module reduces the switching frequency for light load (below 50%) efficiency improvement.
Mechanical Specifications
Case Material
Aluminum alloy
Dimensions
Horizontal package (without heat sink)
50.80 × 25.40 × 11.80 mm
Horizontal package (with heat sink)
51.40 × 26.20 × 16.50 mm
A2S chassis mounting (without heat sink)
76.00 × 31.50 × 21.20 mm
A2S chassis mounting (with heat sink)
76.00 × 31.50 × 25.30 mm
A4S Din-rail mounting (without heat sink)
76.00 × 31.50 × 25.80 mm
A4S Din-rail mounting (with heat sink)
76.00 × 31.50 × 29.90 mm
Weight
without heat sink
Horizontal package/A2S chassis mounting/A4S Din-rail
mounting
26.0g/48.0g/68.0g(Typ.)
with heat sink
Horizontal package/A2S chassis mounting/A4S Din-rail
mounting
34.0g/56.0g/76.0g(Typ.)
Cooling Methods
Free air convection
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 3 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Electromagnetic compatibility (EMC) (EN60950)
Emissions
CE
CISPR32/EN55032 CLASS A (without external components)/ CLASS B (see Fig.3 or Fig.4 for recommended circuit)
RE
CISPR32/EN55032 CLASS A (without external components)/ CLASS B (see Fig.3 or Fig.4 for recommended circuit)
Immunity
ESD
IEC/EN61000-4-2 Contact ±6KV/Air ±8KV
perf. Criteria B
RS
IEC/EN61000-4-3 20V/m
perf. Criteria A
EFT
IEC/EN61000-4-4 ±4KV (see Fig.3 or Fig.4 for recommended circuit)
perf. Criteria B
Surge
IEC/EN61000-4-5
line to line ±2KV (2Ω18uF see Fig.3 for recommended circuit)
line to ground ±4KV (12Ω9uF see Fig.3 for recommended circuit)
perf. Criteria B
CS
IEC/EN61000-4-6 10 Vr.m.s
perf. Criteria A
Electromagnetic Compatibility (EMC) (EN50155)
Emissions
CE
EN50121-3-2 150kHz-500kHz 99dBuV
EN55016-2-1 500kHz-30MHz 93dBuV
RE
EN50121-3-2 30MHz-230MHz 40dBuV/m at 10m
EN55016-2-1 230MHz-1GHz 47dBuV/m at 10m
Immunity
ESD
EN50121-3-2 Contact ±6KV/Air ±8KV
perf. Criteria B
RS
EN50121-3-2 20V/m
perf. Criteria A
EFT
EN50121-3-2 ±2kV 5/50ns 5kHz
perf. Criteria A
Surge
EN50121-3-2 line to line ±1KV (42Ω, 0.5μF)
line to ground ±2KV (42Ω, 0.5μF)
perf. Criteria B
CS
EN50121-3-2 0.15MHz-80MHz 10V r.m.s
perf. Criteria A
Note: All the tests are measured under the conditions of inputs capacitor 100uF/200V or FC-CX1D.
Typical Characteristic Curves
Operating Te mperature( )
Temperature De rating Curve
Output Powe r Percen tage( %)
-40 0 40 71 85
80
60
100
120
40
20
0
Safe Operating A rea
75
with heatsink
without heatsink
Fig. 1
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 4 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Design Reference
1. Typical application
All the DC-DC converters of this series are tested before delivery using the recommended circuit shown in Fig. 2.
Input and/or output ripple can be further reduced by appropriately increasing the input & output capacitor values Cin and Cout and/or by
selecting capacitors with a low ESR (equivalent series resistance). Also make sure that the capacitance is not exceeding the max.
capacitive load value of the product.
DC DC
Vin
G ND
+ Vo
0V
Cin Cout
Fuse
Fig. 2
Vout(VDC)
Fuse
Cin
Cout
3.3/5
2Aslow blow
10µF - 47µF
100µF
12/15
47µF
24
22µF
2. EMC compliance circuit
+V in
-Vin FC -CX1D DC-DC
+Vo
0V
FUSE
+
C0
CY 1
CY 2
Vi n
GND
C2
C1 LOAD
Fig. 3
Fig. 3 List of components
FUSE
Choose according to actual input current
FC-CX1D
FC-CX1D is the EMC auxiliary component of our
company. Input voltage range: 40V-160V
C0
100µF/200V
C1
Refer to the Cin in Fig.2
C2
Refer to the Cout in Fig.2
CY1CY2
1000pF/400VAC
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 5 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Fig. 4
Notes: Part in the Fig. 4 is used for EMC test and part for EMI test
Fig. 4 List of components
C0
100µF/200V
C1C2
0.22µF/250V
C3
Refer to the Cin in Fig.2
LCM1
2.2mH(FL2D-10-222)
LCM2
1.1mH
(material:TN150P-RH12.7*12.7*7.9)
CY1CY2CY3CY4
1000pF/400VAC
C4
Refer to the Cout in Fig.2
Notes: FL2D-10-222 is the EMC auxiliary component of our
company.
3. The products do not support parallel connection of their output
4. For additional information about Mornsun EMC Filter products please refer to
www.mornsun-power.com to download the Selection Guide of EMC Filter
Horizontal Package (without heat sink) Dimensions and Recommended Layout
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 6 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Horizontal Package (with heat sink) Dimensions
URB_LMD-10WR3A2S (without heat sink) Dimensions
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 7 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
URB_LMD-10WHR3A2S (with heat sink) Dimensions
URB_LMD-10WR3A4S (without heat sink) Dimensions
DC/DC Converter
URB1D_LMD-10WR3 Series
2018.09.30-A/2 Page 8 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
URB_LMD-10WHR3A4S(with heat sink) Dimensions
Note:
1. For additional information on Product Packaging please refer to www.mornsun-power.com. The Packaging bag number of Horizontal
packaging: 58200035(without heat sink), 58200051(with heat sink), A2S/ A4S packaging number: 58220022;
2. The maximum capacitive load offered were tested at input voltage range and full load;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal
input voltage and rated output load;
4. All index testing methods in this datasheet are based on Company’s corporate standards;
5. Other product application information, please see DC-DCrailway power supplyConverter Application Notes for specific operation
methods;
6. We can provide product customization service, please contact our technicians directly for specific information;
7. Products are related to laws and regulations: see "Features" and "EMC";
8. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850 Fax: 86-20-38601272 E-mail: sales@mornsun.cn www.mornsun-power.com