Industrial Power Supplies TSP-3P Series, 240-960 Watt CB Features 200% Peak Power! 3-phase input 3AC 400V or 3AC 500V 200 % boost power for up to 5 seconds Alternative to AC transformers Fully regulated 24 VDC output with Scheme EMC LVD IEC 60950-1 UL 60950-1 EN 60950-1 EN 61558-2-16 EN 60204 UL 508 ATEX II3G 10 A, 20 A or 40 A Rugged metal case design qualified for harsh industrial environment High efficiency >92% Operating temperature range: -25C to +60C (full power) Overload and over temperature protection Industrial safety approvals Cost effective design 3-year product warranty The TRACOPOWER TSP-3P series of high performance DIN-rail power supplies offers an economical solution to generate a regulated DC voltage from three-phase mains networks. The smart design achieves a very high efficiency at ultra compact size and very competitive cost. The series provides models with 240, 480 and 960 Watt output power all with additional power reserve of up to 200%. This high peak power guarantees a reliable start-up of loads with high inrush currents such as motors, valves and other industrial loads. In many applications these switching power supplies can also replace mains transformers with rectifiers. Models Order Code Output Power (nom.) TSP 240-124-3PAC400 TSP 240-124-3PAC500 TSP 480-124-3PAC400 TSP 480-124-3PAC500 TSP 960-124-3PAC400 TSP 960-124-3PAC500 240 W 480 W 960 W Input Voltage (nom.) Output Voltage (nom.) *Output Current (nom.) 3 AC 400 V 24 VDC 10 A 3 AC 500 V 24 VDC 10 A 3 AC 400 V 24 VDC 20 A 3 AC 500 V 24 VDC 20 A 3 AC 400 V 24 VDC 40 A 3 AC 500 V 24 VDC 40 A * 200% peak current for up to 5 sec. http://www.tracopower.com Page 1 of 6 Industrial Power Supplies TSP-3P Series 240-960 Watt Input Specifications Input voltage range star-net configuration (2-phase operation not possible) 400 VAC models: 320 - 440 VAC 500 VAC models: 400 - 550 VAC (derating below 410 VAC see graph 2) Input voltage frequency 47 - 63 Hz Harmonic limits EN 61000-3-2, Class B (for <16 A per phase) Power factor >0.8 at full load Recommended circuit breaker, 6.0 A characteristic B Output Specifications Output voltage: 24 VDC (fixed) Regulation - Input / load variation 1 % max. + voltage drop at low input voltage and/or boost power, see graph 1 & 2 Boost power - - - - Ripple and noise (20MHz bandwidth) - nominal operation 100 mV pk-pk typ. - boost power operation up to 750 mV pk-pk max. current duty cycle max. cycle time input voltage requirements 200 % of nominal output current <10 % 5 sec limited by timer (automatic restart after 30 sec.) see graph 1 & 2 Rise time 200 ms typ. Current limitation at 230 % of nominal output current, constant current Overvoltage protection 33 V typ. Overtemperature protection switch off at overtemperature (automatic restart) Power back immunity 35 VDC continuouse, 40 VDC for one second Output Power Derating Graph 1: 400 VAC input models Graph 2: 500 VAC input models VDCout VDCout 25 25 os bo 22 20 0% 22 21 320 t os bo 0% 23 t 23 50% load lloo aad d 24 20 100% 100%load load 110 000 %% 24 21 330 340 350 360 370 430 440 VACin 400 410 420 430 450 460 540 550 VACin General Specifications Temperature range - - - - Full power operation Max. operating Start up In accordance to UL508 -25C to +60C +70C, 2.5 %/K derating above +60C -40C -25C to +40C Cooling convection cooling, no internal fan Humidity (non condensing) 95 % rel. H max. Reliability, calculated MTBF at +25C acc. to IEC 61709 - TSP 240 & 480 >1 Mio h - TSP 960 >800`000 h Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) http://www.tracopower.com Page 2 of 6 Industrial Power Supplies TSP-3P Series 240-960 Watt General Specifications Electromagnetic compatibility (EMC), Emissions EN 61000-6-3 - Conducted RI suppression on input EN 55011 class B, EN 55022 class B, - Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity - Electrostatic discharge (ESD) - Radiated RF field immunity - Electrical fast transient burst immunity input burst immunity output - Surge immunity L-L L - PE + Output - - Output + Output - PE - Output - PE - Immunity to conducted RF disturbances - Mains voltage dips and interruptions Safety standards - - - - - - EN 61000-6-2 IEC/EN 61000-4-2 8 kV / 15 kV criteria tba IEC/EN 61000-4-3 10 V/m criteria tba IEC/EN 61000-4-4 4 kV criteria tba IEC/EN 61000-4-4 2 kV criteria tba IEC/EN 61000-4-5 2 kV criteria tba IEC/EN 61000-4-5 4 kV criteria tba IEC/EN 61000-4-5 0.5 kV criteria tba IEC/EN 61000-4-5 0.5 kV criteria tba IEC/EN 61000-4-5 0.5 kV criteria tba IEC/EN 61000-4-6 10 V criteria tba IEC/EN 61000-4-11 IEC/EN 60950-1, UL 60950-1 Information technology equipment Industrial control equipment UL 508 listed, CSA C22.2 No. 107.1 Equipment for use in explosive atmospheres ATEX 94/9/EC Electrical equipment for machines EN 60204 Electronic equipment for power installations EN 50178 Safety of power transformers EN 61558-2-16 Safety approvals and CB report for IEC 60950-1 SIQ certificate for EN 60950-1 II3G Ex nA nC llC T3 UL approvals for UL 508 listed Curtis-Straus certificate for UL 60950-1 (2nd) Bureau Veritas for other standards - Certification documents www.tracopower.com/overview/tsp-3p Environmental compliance - Reach www.tracopower.com/info/reach-declaration.pdf - RoHS RoHS directive 2002/95/EC Environment - Vibration acc. IEC 60068-2-6; 0.075 mm / 10 - 55 Hz, - Shock acc. IEC 60068-2-27 11ms / 15 g Status signals - DC-OK relay contact DC OK = contact closed at >20...22 VDC rated: 30 VDC/1.0 A for 24 VDC models - DC-OK indication green LED at >20...22 VDC - Phase error indication red blinking LED if one or two phases are missing (function only if earth is connected) - Overload / Overtemperature red LED on at >100% nominal load (5 sec. count down for boost power is activated) red blinking LED at temperature shut down (manual restart required - mains disconnect for 5 sec.) - Automatic restart indication red blinking LED during overload recovery periode Enclosure material aluminium (chassis) / stainless steel (cover) Mounting - DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) - Wall mounting (option) with wall mounting bracket - see page 6 Connection screw terminals Installation instructions www.tracopower.com/overview/tsp-3p All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 6 Industrial Power Supplies TSP-3P Series 240-960 Watt Outline Dimensions 54.0 110.0 (2.13) _ + DC-OK OVER-LOAD (3.15) RESTART PHASE FAULT 80.0 110.0 (4.33) DC-ON (4.33) 38.5 (1.52) 240 Watt models L2 L3 14.5 5.0 (0.57) 80.0 480 Watt models Weight: 575 g (1.27 lb) 125.0 (3.15) _ _ + + DC-OK (4.92) (1.77) (0.20) 25.0 (0.98) 45.0 L1 OVER-LOAD (3.41) 125.0 (4.92) DC-ON RESTART 86.5 PHASE FAULT L1 L2 L3 46.0 5.0 (0.20) (1.81) 25.0 (0.98) 17.0 (0.67) 25.0 (0.98) Weight: 1.05 kg (2.31 lb) Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) http://www.tracopower.com Page 4 of 6 Industrial Power Supplies TSP-3P Series 240-960 Watt Outline Dimensions 960 Watt models Weight: 2.35 kg (5.19 lb) 25.0 25.0 (0.98) (0.98) 21.0 123.0 (4.84) 125.0 (6.50) (4.92) 86.5 (3.41) 125.0 (4.92) 45.0 (1.77) 165.0 (0.83) OVER-LOAD RESTART L1 L2 L3 PHASE FAULT DC-OK _ _ + + DC-ON Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) http://www.tracopower.com Page 5 of 6 Industrial Power Supplies TSP-3P Series 240-960 Watt TSP-WMK Wall Mounting Bracket Order code For models Content of kit TSP-WMK03 TSP-WMK02 240 W 1 bracket 480 W & 960 W 2 brackets TSP-WMK03 85.0 (3.35) 42.5 (1.67) 34.5 (1.36) 34.5 (1.36) R 2.12 (0.083) 7.0 (0.28) 15.0 (0.59) TSP-WMK02 37.0 (1.45) 74.0 (2.91) 2.0 (0.08) 25.0 (0.98) 25.0 (0.98) 55.0 (2.16) 4 x positioning holes 2.0 (0.08) 2.0 (0.08) R 2.12 (0.083) TSP 240-124-3PAC400 TSP 240-124-3PAC500 2.0 (0.08) o 4.25 (0.17) R 2.12 (0.083) o 4.25 (0.17) R 2.12 (0.083) o 4.25 (0.17) 15.0 (0.59) Material: 2 mm Mild Steel Tolerance: 0.1mm ( 0.004) 46.0 (1.81) TSP 480-124-3PAC400 TSP 480-124-3PAC500 33.0 (1.30) 96.0 (3.78) 62.5 (2.46) 50.0 (1.97) o 4.3 (0.17) 2x o4.3 (0.17) TSP 960-124-3PAC400 TSP 960-124-3PAC500 2.0 (0.08) 30.0 (1.18) 2.0 (0.08) 25 (0.98) 4 x positioning holes Material: 2 mm Mild Steel Tolerance: 0.1mm ( 0.004) 62.5 (2.46) (0.59) 7.0 (0.28) 173.0 (6.81) 15.0 Dimensions: [mm] ( ) = Inch Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. July 11, 2018 Page 6 of 6 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TRACO Power: TSP 240-124-3PAC500 TSP 960-124-3PAC400 TSP 480-124-3PAC400 TSP 480-124-3PAC500 TSP 960-1243PAC500 TSP 240-124-3PAC400