22/10/2012 www.crouzet.com 83139 Flameproof 831391 Part number IP 67 protection against hydrocarbons, detergents Double break switching Double insulated or Atex flameproof casing Choice of actuators Part numbers Type Function Connections 83139003 Standard 831390 I (changeover) Standard lead output MADE TO ORDER Standard 831390 I (changeover) Lead output on right/left CONTACT US Standard 831390 I (changeover) Cable output MADE TO ORDER Low temperature 831395 I (changeover) Standard lead output MADE TO ORDER Low temperature 831395 I (changeover) Lead output on right/left CONTACT US Low temperature 831395 I (changeover) Cable output CONTACT US Double insulated 831392 I (changeover) Standard lead output CONTACT US Double insulated 831392 I (changeover) Lead output on right/left MADE TO ORDER Double insulated 831392 I (changeover) Cable output MADE TO ORDER Flameproof 831391 I (changeover) Standard lead output MADE TO ORDER Flameproof 831391 I (changeover) Lead output on right/left CONTACT US Flameproof 831391 I (changeover) Cable output Specifications Electrical characteristics Rating nominal / 250 V (A) Rating thermal / 250 V (A) 6 11 Mechanical characteristics Maximum operating force (N) Min. Release force (N) Maximum total travel force (N) Max. permitted overtravel force (N) Maximum rest position (mm) Operating position depending on position of fixing holes (mm) Maximum differential travel (mm) Min. overtravel (mm) Ambient operating temperature (C) Mechanical life (operations) Contact gap (mm) Weight (g) 3 0,6 4 10 B = 9,8 B = 8.7 0.4 0,35 0,1 0,25 -20 +80 5 x 10 6 0,3 x 2 37 Fixations Fixings - 4 holes (standard) Fixing - 2 holes B Connections Connection 4 flexible leads Standard wire output Wire output on right Wire output on left 0.75 mm2 length 0.50 mm O ext. 2.3 mm S D G Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 www.crouzet.com Comments Characteristics specific to 831391 - Conform to standards EN 50014 and 50018 - Conform to the European directive 94/9/EC concerning potentially explosive atmospheres - Group II classified for potentially explosive atmospheres other than mines subject to firedamp - Temperature class T6, max. surface temperature 80 C - CE Test Certificate type n LCIE 02 ATEX 0034 U - Notification number : LCIE 03 ATEXQ8002 Additional specifications Components Material - Case : polyester UL94V0 - Contacts : silver - Membrane : nitrile for 83 139 0 silicon for 83 139 1/2/5 Levers - stainless steel - Roller : polyamide Principles Dimensions (mm) Product 83 139 0 - 1 - 5 - B fixing = 2 holes No Legend Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 www.crouzet.com R : 1.5 spherical Lead reference on casing Dimensions (mm) Actuator mounting positions Type 139 Fixing 4 holes Dimensions (mm) Actuator mounting positions Type 139 Fixing 2 holes Dimensions (mm) Actuator mounting positions Type 161 Fixing 4 holes Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 Dimensions (mm) Actuator mounting positions Type 161 Fixing 2 holes Dimensions (mm) Actuators 139 EX Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 22/10/2012 Dimensions (mm) Actuators 139 AX Dimensions (mm) Actuators 161 A Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 22/10/2012 Dimensions (mm) Actuators 161 E Dimensions (mm) Actuators 161 F Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 22/10/2012 Dimensions (mm) Actuators 161 G Curves Operating curve Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 22/10/2012 No www.crouzet.com Legend Number of cycles Resistive circuit Inductive circuit Mechanical life limit Current in Amps Connections Actuators and fixing positions Other information Product marking (83 139 1) II 2 G EEx d IIC T6 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 22/10/2012 www.crouzet.com Key to these symbols : - Equipment used in potentially explosive atmospheres II - Equipment group for surface use 2 - Equipment category for zone 1 G - Gas EEx - The equipment complies with the protection methods standardised by CENELEC (European standards) d - Protection method used : "d" flameproof casing II - Surface industry C - Most severe gas subdivision including hydrogen, acetylene and carbon disulphide T6 - Temperature class corresponding to +85 C At the time of ordering, the customer must specify : - The operating zone (0, 1 or 2) - The type of atmosphere (gas or dust) - The type of gas - The ambient operating temperature Product adaptations *Special levers *Special leads, cables, cable harnesses *Specific operating temperatures Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 831391CBB.5.0 831391CBB.5.P 831391CBB.5.R