Circuit Diagram
L
N
L
N
EE
RCX
CY
CY
CX
Features
Nor th Amer ican and Metric fuse
holders available
Fuse holder and double pole power ON/OFF switch
provided in a convenient/compact package
Suitable for products that must confor m
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Metal case provides effective EMI shielding
Easy access fuse drawer with space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 47)
Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
Switched and Fused Filtered
Power Entry Modules
46
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fair view, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
Applications
Computers and
peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instr uments
Telecommunications equipment
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
B(S) = Bolt-in terminals or (Snap-in ter minals)
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
* Substitute BSF or SSF for XXX
BSF - Bolt-in switched and fused
SSF - Snap-in switched and fused
Specifications
Model* Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX1 CX2 (L1) Rise (Max.)
64-XXX-020-3-12
64-XXX-020-3-04
64-XXX-020-3-14
64-XXX-020-3-06
64-XXX-020-5-12
64-XXX-020-5-04
64-XXX-020-5-14
64-XXX-020-5-06
64-XXX-040-3-12
64-XXX-040-3-04
64-XXX-040-3-14
64-XXX-040-3-06
64-XXX-040-5-12
64-XXX-040-5-04
64-XXX-040-5-14
64-XXX-040-5-06
64-XXX-060-3-12
64-XXX-060-3-04
64-XXX-060-3-14
64-XXX-060-3-06
64-XXX-060-5-12
64-XXX-060-5-04
64-XXX-060-5-14
64-XXX-060-5-06
65-XXX-020-3-12
65-XXX-020-3-04
65-XXX-020-3-14
65-XXX-020-3-06
65-XXX-020-5-12
65-XXX-020-5-04
65-XXX-020-5-14
65-XXX-020-5-06
65-XXX-040-3-12
65-XXX-040-3-04
65-XXX-040-3-14
65-XXX-040-3-06
65-XXX-040-5-12
65-XXX-040-5-04
65-XXX-040-5-14
65-XXX-040-5-06
65-XXX-060-3-12
65-XXX-060-3-04
65-XXX-060-3-14
65-XXX-060-3-06
65-XXX-060-5-12
65-XXX-060-5-04
65-XXX-060-5-14
65-XXX-060-5-06
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
2A 45°C10.5mH
10.5mH
4.2mH
4.2mH
1.6mH
1.6mH
45°C
45°C
45°C
45°C
45°C
0.35mA 2200pF
3300pF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
2200pF
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
4A
6A
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
2A
4A
6A
64-65-BSF/64-65-SSF Series
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
.248
(6.3)
2.556
(65)
2.348
(59.7)
1.313 (33.4)
1.101 (28)
Fast-on tab #250
2.273 (57.8)
1.133
(28.8)
2.340
(59.5)
Panel cutout dimension
mount from back side
1.514 (38.8)
A
R .079
(2.0) Thickness of Panel A
.031 (0.8t) 2.430 (61.8±0.1)
.039 (1.0t) 2.446 (62.2±0.1)
.047 (1.2t) 2.462 (62.6±0.1)
.059 (1.5t) 2.470 (62.8±0.1)
.071 (1.8t) 2.473 (62.9±0.1)
.079 (2.0t) 2.477 (63.0±0.1)
* General Tolerance
± .039 (1.0)
* Metal Case
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
Dimensions in inches (mm)
0.35 mA Leakage Versions
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
2 Amp
4 Amp
6 Amp
90
0.50 mA Leakage Versions
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
2 Amp
4 Amp
6 Amp
90
64/65-B(S)SF-*-*-02(04,06)
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
6 Amp
90
100
4 Amp
2 Amp
64/65-B(S)SF-*-*-11(12,14)
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
6 Amp
90
100
4 Amp
2 Amp
.248
(6.3)
2.556
(65)
2.348
(59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
F ast-on Tab #250
2.273 (57.8) 1.133
(28.8)
2.340
(59.5)
1.573
(40.±0.2)
2.399 (61)
Panel cutout
dimension
mount from
back side
R .059
(1.5)
2 - .142
(3.6) Hole
1.526 (38.8)
1.16±
(29.5± )
0.5
0
.334
0
t= .031 (0.8)
Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
64/65-SSF Series
Dimensions
64/65-BSF Series
Temperature Characteristics
Switched and Fused Filtered
Power Entry Modules
47
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fair view, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
L
N
L
N
EE
C
Y1
C
Y2
LINE
LOAD
RCX1
L1CX2
Note: C
Y1
and C
Y2
capacitors
omitted on 66/67
B(S)F-XXX-1-X Filters
Circuit Diagram
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in ter minals)
* Substitute BSF or SSF for XXX
BSF - Bolt-In Switched and Fused
SSF - Snap-In Switched and Fused
Features
Metric and Nor th Amer ican fuse holders available
Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package
Suitable for products that must confor m
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors
Designed to meet requirements for non-patient
and patient care equipment
Metal case provides effective EMI shielding
Easy access fuse drawer - space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 49)
Applications
Medical equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
Digital equipment (including
switching power supplies)
General purpose filter for
susceptibility or high frequency
clean upapplications
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
48
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fair view, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
10.5mH
4.2mH
1.6mH
2A
4A
6A
125
VAC
40°C
45°C
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Note: Test Voltage: 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
Voltage Drop: 1V max. at rated current
Rated Rated Leakage
Temp.
Model*
Voltage Current Current
Capacitance Induct. Rise
50/60Hz (Max.)
CYCX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
Specifications
10.5mH
4.2mH
1.6mH
2A
4A
6A
250
VAC
40°C
45°C
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Rated Rated Leakage
Temp.
Model*
Voltage Current Current
Capacitance Induct. Rise
50/60Hz (Max.)
CYCX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
.075mA
.01mA
0.1mA
.075mA
.01mA
.01mA
.075mA
.01mA
0.1mA
Tested and found to be
IAW VDE 0565 Part 3
Switched and Fused Filtered
Power Entry Modules
66-67-BSF/66-67-SSF Series
50
Level
Meter
50
13
24
Filter
Oscillator
5050
50
Level
Meter
50
13
24
Filter
Oscillator
50
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
Common Mode Normal Mode
0.01 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.01 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
Dimensions
.248
(6.3)
2.556
(65)
2.348
(59.7)
1.313 (33.4)
1.101 (28)
Fast-on tab #250
2.273 (57.8)
1.133
(28.8)
2.340
(59.5)
Panel cutout dimension
mount from back side
1.514 (38.8)
A
R .079
(2.0) Thickness of Panel A
.031 (0.8t) 2.430 (61.8±0.1)
.039 (1.0t) 2.446 (62.2±0.1)
.047 (1.2t) 2.462 (62.6±0.1)
.059 (1.5t) 2.470 (62.8±0.1)
.071 (1.8t) 2.473 (62.9±0.1)
.079 (2.0t) 2.477 (63.0±0.1)
* General Tolerance
± .039 (1.0)
* Metal Case
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
.248
(6.3)
2.556
(65)
2.348
(59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
F ast-on Tab #250
2.273 (57.8) 1.133
(28.8)
2.340
(59.5)
1.573
(40.±0.2)
2.399 (61)
Panel cutout
dimension
mount from
back side
R .059
(1.5)
2 - .142
(3.6) Hole
1.526 (38.8)
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
66/67-BSF Series 66/67-SSF Series
Dimensions in inches (mm)
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
49
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fair view, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Switched and Fused Filtered
Power Entry Modules