Switched and Fused Filtered Power Entry Modules Switched and Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BSF/64-65-SSF Series Features Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder and double pole power ON/OFF switch provided in a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Metal case provides effective EMI shielding Easy access fuse drawer with space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25C to +85C (including temperature rise, see graph on page 47) Applications Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Circuit Diagram L L CY CX E CX E R CY N N Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 64-XXX-020-3-12 64-XXX-020-3-04 64-XXX-020-3-14 64-XXX-020-3-06 250VAC 2A 64-XXX-020-5-12 64-XXX-020-5-04 64-XXX-020-5-14 64-XXX-020-5-06 64-XXX-040-3-12 64-XXX-040-3-04 64-XXX-040-3-14 64-XXX-040-3-06 250VAC 4A 64-XXX-040-5-12 64-XXX-040-5-04 64-XXX-040-5-14 64-XXX-040-5-06 64-XXX-060-3-12 64-XXX-060-3-04 64-XXX-060-3-14 64-XXX-060-3-06 250VAC 6A 64-XXX-060-5-12 64-XXX-060-5-04 64-XXX-060-5-14 64-XXX-060-5-06 65-XXX-020-3-12 65-XXX-020-3-04 65-XXX-020-3-14 65-XXX-020-3-06 125VAC 2A 65-XXX-020-5-12 65-XXX-020-5-04 65-XXX-020-5-14 65-XXX-020-5-06 65-XXX-040-3-12 65-XXX-040-3-04 65-XXX-040-3-14 65-XXX-040-3-06 125VAC 4A 65-XXX-040-5-12 65-XXX-040-5-04 65-XXX-040-5-14 65-XXX-040-5-06 65-XXX-060-3-12 65-XXX-060-3-04 65-XXX-060-3-14 65-XXX-060-3-06 125VAC 6A 65-XXX-060-5-12 65-XXX-060-5-04 65-XXX-060-5-14 65-XXX-060-5-06 Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC B(S) = Bolt-in terminals or (Snap-in terminals) 46 Leakage Current (Max.) CY 0.35mA 2200pF Capacitance CX1 0.22uF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 0.47uF 2200pF 0.22uF 0.50mA 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 0.47uF 2200pF 0.22uF 0.50mA 0.47uF Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 CX2 Inductance (L1) NONE 0.22uF NONE 10.5mH 0.47uF NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 4.2mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 1.6mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 10.5mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 4.2mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 1.6mH NONE 0.22uF NONE 0.47uF * Substitute BSF or SSF for XXX BSF - Bolt-in switched and fused SSF - Snap-in switched and fused Temperature Rise (Max.) 45C 45C 45C 45C 45C 45C SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Temperature Temperature Characteristics Characteristics 120 100 Current (%) Switched and Fused Filtered Power Entry Modules 80 60 40 20 0 Dimensions 30 40 50 60 70 Ambient Temperature (C) 80 90 64/65-SSF Series 64/65-BSF Series 1.947 (49.5) 1.101 (28) 20 1.313 (33.4) 1.101 (28) .248 (6.3) .248 (6.3) 1.133 (28.8) 1.514 (38.8) 1.526 (38.8) Fast-on tab #250 t= .031 (0.8) 2.556 (65) 2.556 (65) 2.340 (59.5) 2.348 (59.7) 2.348 (59.7) 2.340 (59.5) O.142 (3.6) R .079 (2.0) 2 - .142 (3.6) Hole R .059 (1.5) A t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16.334 0 (40.0.2) (29.5 0.5) 0 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (400.2) 2.273 (57.8) Dimensions in inches (mm) Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.80.1) 2.446 (62.20.1) 2.462 (62.60.1) 2.470 (62.80.1) 2.473 (62.90.1) 2.477 (63.00.1) Switched and Fused Filtered Power Entry Modules For General Purpose Applications * General Tolerance .039 (1.0) * Metal Case 2.399 (61) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 50 1 3 Filter 2 4 50 Level Meter Oscillator 50 0.35 mA Leakage Versions 100 80 90 70 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 50 Level Meter 50 64/65-B(S)SF-*-*-02(04,06) 90 60 50 40 4 Amp 30 6 Amp 20 70 60 50 2 Amp 40 4 Amp 30 10 6 Amp 20 0 0.1 0.2 1 0.5 2 5 Frequency (MHz) 10 20 0 0.1 50 0.50 mA Leakage Versions 0.5 1 2 5 Frequency (MHz) 10 20 50 20 50 100 80 90 70 80 Insertion Loss (dB) 2 Amp 60 50 40 4 Amp 30 6 Amp 20 70 60 4 Amp 6 Amp 50 2 Amp 40 30 10 0 0.1 0.2 64/65-B(S)SF-*-*-11(12,14) 90 Insertion Loss (dB) 50 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 47 Switched and Fused Filtered Power Entry Modules 66-67-BSF/66-67-SSF Series Features Tested and found to be IAW VDE 0565 Part 3 Metric and North American fuse holders available Fuse holder and a double pole power ON/OFF switch provides a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Provides susceptibility protection without the leakage current associated with line-to-ground capacitors Designed to meet requirements for non-patient and patient care equipment Metal case provides effective EMI shielding Easy access fuse drawer - space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25C to +85C (including temperature rise, see graph on page 49) Applications Medical equipment Industrial equipment Telecommunications equipment Measuring and testing instruments Digital equipment (including switching power supplies) General purpose filter for susceptibility or high frequency "clean up" applications Circuit Diagram L L L1 R CX1 CX2 CY1 E E LOAD Note: CY1 and CY2 capacitors omitted on 66/67 B(S)F-XXX-1-X Filters LINE Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications CY2 N N Specifications Model* 66-XXX-020-0-12 66-XXX-020-0-04 66-XXX-020-0-14 66-XXX-020-0-06 66-XXX-020-1-12 66-XXX-020-1-04 66-XXX-020-1-14 66-XXX-020-1-06 66-XXX-020-4-12 66-XXX-020-4-04 66-XXX-020-4-14 66-XXX-020-4-06 66-XXX-040-0-12 66-XXX-040-0-04 66-XXX-040-0-14 66-XXX-040-0-06 66-XXX-040-1-12 66-XXX-040-1-04 66-XXX-040-1-14 66-XXX-040-1-06 66-XXX-040-4-12 66-XXX-040-4-04 66-XXX-040-4-14 66-XXX-040-4-06 66-XXX-060-0-12 66-XXX-060-0-04 66-XXX-060-0-14 66-XXX-060-0-06 66-XXX-060-1-12 66-XXX-060-1-04 66-XXX-060-1-14 66-XXX-060-1-06 66-XXX-060-4-12 66-XXX-060-4-04 66-XXX-060-4-14 66-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF .075mA 330pF 0.47uF 0.22uF 2A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 250 VAC 0.22uF 4A .01mA NONE 0.47uF 0.22uF .01mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 0.22uF 6A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF Note: Test Voltage: 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC Voltage Drop: 1V max. at rated current 48 Temp. Induct. (L1) Model* 67-XXX-020-0-12 67-XXX-020-0-04 67-XXX-020-0-14 67-XXX-020-0-06 67-XXX-020-1-12 67-XXX-020-1-04 67-XXX-020-1-14 67-XXX-020-1-06 67-XXX-020-4-12 67-XXX-020-4-04 67-XXX-020-4-14 67-XXX-020-4-06 67-XXX-040-0-12 67-XXX-040-0-04 67-XXX-040-0-14 67-XXX-040-0-06 67-XXX-040-1-12 67-XXX-040-1-04 67-XXX-040-1-14 67-XXX-040-1-06 67-XXX-040-4-12 67-XXX-040-4-04 67-XXX-040-4-14 67-XXX-040-4-06 67-XXX-060-0-12 67-XXX-060-0-04 67-XXX-060-0-14 67-XXX-060-0-06 67-XXX-060-1-12 67-XXX-060-1-04 67-XXX-060-1-14 67-XXX-060-1-06 67-XXX-060-4-12 67-XXX-060-4-04 67-XXX-060-4-14 67-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF 0.04mA 330pF 0.47uF 0.22uF 2A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 125 VAC 0.22uF 4A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 0.22uF 6A Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF Temp. Induct. (L1) Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-In Switched and Fused SSF - Snap-In Switched and Fused SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Temperature Characteristics 120 100 Current (%) Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 80 60 40 20 20 30 40 50 60 70 Ambient Temperature (C) 80 90 Dimensions 66/67-BSF Series 1.947 (49.5) 1.101 (28) 66/67-SSF Series .248 (6.3) 1.313 (33.4) 1.101 (28) 1.526 (38.8) .248 (6.3) 1.133 (28.8) 1.514 (38.8) Fast-on tab #250 2.556 (65) t= .031 (0.8) 2.556 (65) 2.348 (59.7) 2.340 (59.5) O.142 (3.6) 2 - .142 (3.6) Hole R .079 (2.0) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (400.2) 2.340 (59.5) 2.348 (59.7) R .059 (1.5) A Dimensions in inches (mm) 2.399 (61) Common Mode 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 90 60 2 Amp 40 30 20 2 Amp 50 40 30 4 Amp 6 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 90 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 40 30 20 1 2 5 Frequency (MHz) 10 20 50 2 Amp 60 50 40 4 Amp 30 6 Amp 10 10 0 0.1 0.5 20 6 Amp 4 Amp 0.2 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current Insertion Loss (dB) 50 Level Meter 50 60 20 6 Amp 4 Amp 50 0.01 mA Leakage Current 0.01 mA Leakage Current 90 50 * General Tolerance .039 (1.0) * Metal Case Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.80.1) 2.446 (62.20.1) 2.462 (62.60.1) 2.470 (62.80.1) 2.473 (62.90.1) 2.477 (63.00.1) Normal Mode 1 3 Filter 2 4 Oscillator 50 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.0.2) (29.5 +0.5) -0 2.273 (57.8) Switched and Fused Filtered Power Entry Modules 0 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 49