Note: C
Y1
and C
Y2
capacitors
omitted on 66/67
B(S)F-XXX-1-X Filters
Circuit Diagram
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in ter minals)
* Substitute BSF or SSF for XXX
BSF - Bolt-In Switched and Fused
SSF - Snap-In Switched and Fused
Features
■Metric and Nor th Amer ican fuse holders available
■Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package
■Suitable for products that must confor m
to FCC and FTZ requirements
■Meets over voltage category II of IEC 664
and complies with IEC 950
■Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors
■Designed to meet requirements for non-patient
and patient care equipment
■Metal case provides effective EMI shielding
■Easy access fuse drawer - space for spare fuse
■Flange-mounted or snap-in styles available
for quick mounting
■Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 49)
Applications
■Medical equipment
■Industrial equipment
■Telecommunications equipment
■Measuring and testing instruments
■Digital equipment (including
switching power supplies)
■General purpose filter for
susceptibility or high frequency
“clean up”applications
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
48
SPECTRUM CONTROL INC. •8031 Avonia Rd. •Fair view, PA 16415 •Phone: 814-474-2207 •Fax: 814-474-2208 •Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH •Hansastrasse 6 •91126 Schwabach, Germany •Phone: (49)-9122-795-0 •Fax: (49)-9122-795-58
10.5mH
4.2mH
1.6mH
2A
4A
6A
125
VAC
40°C
45°C
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Note: Test Voltage: 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩmin. at 500VDC
Voltage Drop: 1V max. at rated current
Rated Rated Leakage
Temp.
Model*
Voltage Current Current
Capacitance Induct. Rise
50/60Hz (Max.)
CYCX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
Specifications
10.5mH
4.2mH
1.6mH
2A
4A
6A
250
VAC
40°C
45°C
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Rated Rated Leakage
Temp.
Model*
Voltage Current Current
Capacitance Induct. Rise
50/60Hz (Max.)
CYCX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
.075mA
.01mA
0.1mA
.075mA
.01mA
.01mA
.075mA
.01mA
0.1mA
Tested and found to be
IAW VDE 0565 Part 3
Switched and Fused Filtered
Power Entry Modules
66-67-BSF/66-67-SSF Series