MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
resistive or inductive load.
RBU1001M
THRU
RBU1007M
MAXIMUM RATINGS
(@ TA=25
OC unless otherwise noted)
ELECTRICAL CHARACTERISTICS
(@TA=25
OC unless otherwise noted)
Dimensions in inches and (millimeters)
FEATURES
* Surge overload rating: 200 amperes peak
* Mounting position: Any
* Low leakage
* Low forward voltage
MECHANICAL DATA
*
*
Epoxy: Device has UL flammability classification 94V-O
RBU
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T
C
= *100
o
C (Note 4)
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Isolation Voltage of case
Typical Thermal Resistance (Note 1)
Typical Current Squared Time
SYMBOL
V
RRM
V
V
ISO
DC
I
FSM
T
J
, T
STG
V
RMS
UNITS
Volts
V
AC
Volts
Amps
10.0
200
165.9
1600
2.3
26
Amps
A2/S
0
C/W
0
C
Operating and Storage Temperature Range
RqJC
RqJA
I
O
-55 to + 150
Volts
100
RBU1001M RBU1003M RBU1005MRBU1002M RBU1004M
200 800
RBU1006M
50
100 200 80050
70 140 56035
1000
RBU1007M
1000
700
400
400
280
600
600
420
2010-05
REV:B
CHARACTERISTICS
at Rated DC Blocking Voltage
V
F
SYMBOL
I
R
uAmps
Maximum DC Reverse Current
Maximum Instantaneous Forward Voltage at 5.0A DC Volts
5.0
@T
A
= 100
o
C
@T
A
= 25
o
C
1.1
100
UNITS
RBU1001M RBU1003M RBU1005M
RBU1002M RBU1004M RBU1006M RBU1007M
NOTES : 1.Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3. Equivalent to Vishay's GBU10 Series.
4. "*" Heat Sink Temperature.
.880 (22.3)
.860 (21.8)
.160 (4.1)
.512 (13.0)
.140 (3.5)
.085 (2.16)
.075 (1.90)
.140 (3.56)
.130 (3.30)
.022 (0.56)
.018 (0.46)
.080 (2.03)
.065 (1.65)
.710 (18.0)
.690 (17.5)
.050 (1.27)
.040 (1.02) .080 (2.03)
.060 (1.52)
.740 (18.8)
.720 (18.3)
.100 (2.54)
.085 (2.16)
.210 (5.33)
.190 (4.83)
UL listed the recognizde component directory file # E252754
I2t
5. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 10.0 Amperes
AVERAGE RECTIFIED FORWARD CURRENT, (A)
NUMBER OF CYCLE
POWER DISSIPATION, (W)
INSTANTANEOUS FORWARD VOLTAGE, (V)
0
0
34
20
10
30
INSTANTANEOUS FORWARD CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
0
10
5
2
1
0.5
0.2
30
20
2 4 6 8 10 12 14
1.61.2 1.40.60.4 0.8 10.2
2 10 20 5010
100
0
200
300
5 100
RATING AND CHARACTERISTICS CURVES ( RBU1001M THRU RBU1007M )
FIG.3 SURGE FORWARD CURRENT CAPABILITY
FIG.1 TYPICAL INSTANTANEOUS FORWARD
CHARACTERITICS FIG.2 POWER DISSIPATION
AMBIENT TEMPERATURE, (OC)
PEAK FORWARD SURGE CURRENT, (A)
0
2
3
1
0
4
8040 120 160
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
HEAT SINK TEMPERATURE, (OC)
AVERAGE FORWARD CURRENT, (A)
10
0
6
8
10
2
4
30 50 70 90 110 130 150 170
FIG.5 TYPICAL FORWARD CURRENT
DERATING CURVE
MOUNTING TORQUE (kg.cm)
THERMAL RESISTANCE (OC/W)
2
0
1.2
0.8
0.4
1.6
2.4
2.0
3 4 5 6 7 8
FIG.6 CONTACT THERMAL RESISTANCE fcf
Pulse test
per one diode
T
C
= 150OC (TYP)
T
C
= 25OC (TYP)
non-repetitive
Tj=25
1 cycle
8.3ms 8.3ms
0
I
FSM
sine wave on glass-epoxi substrate
P.C.B
soldering land 5mmf
sine wave
R-load
free in air
heatsink
Tc Tc
sine wave
R-load
on heatsink
with thermal compound
sine wave
T
J
= 150 OC
Marking Description
R B U 1 0 0 X M
V Y W W
Rectron Logo Part No.
Year – code
(Y:Last digit of year&
A:2010, B:2011……
)
Week – code
WW01~52
Voltage-code
1-------50V 5-------600V
2-------100V 6-------800V
3-------200V 7-------1000V
4-------400V
UL Logo
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE EA PER BOX INNER BOX SIZE
(mm) CARTON SIZE
(mm) EA PER CARTON GROSS
WEIGHT(Kg)
TUBE PACK
PACKAGE EA PER BOX INNER BOX SIZE
(mm) CARTON SIZE
(mm) EA PER CARTON WEIGHT(Kg)
PACKING CODE
PACKING CODE
RBU
-C 1,000 2,000 13.62490*135*110 510*293*131
RBU
-B
450 240*239*35 502*251*126 2,700 13.00
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.
DISCLAIMER NOTICE