Model SC1000/SC2000 Transducer Display and Signal Conditioning Unit DESCRIPTION Available output channels for the SC2000 include: The SC series models are self-calibrating microprocessor- * Contact relays for the four standard limits or additional limits based transducer signal conditioners when used with sig mod equipped transducers. Indicators are available with several different types of input channels and output channels. When used (max. 16 limits/chassis) * Isolated digital-to-analog voltage (5 Vdc or 0 Vdc to 10 Vdc) or current (4 mA to 20 mA) with unamplified strain gage transducers that have the signature calibration module installed, these instruments will completely In addition to the physical input and output channels, up to self calibrate zero, span, decimal point, and engineering units seven virtual channels can be configured to assist in many po- automatically. tential applications. Input channels are available for a variety of transducers. Each Four channel chassis input channel includes an excitation power supply and either an The models SC1000 and SC2000 can hold up to four physi- isolated voltage or isolated current analog output. cal channels in their 3/8 DIN Aluminum bench-top chassis. A * Unamplified pressure or load bright, dual-line 16-character display can display 5, 6 or 7 * Pressure or load with internal voltage amplifiers numeric digits; simply press a button to select the next channel * Pressure or load with internal or external two-wire to be viewed. If configured for split-screen operation, up to four channel values can be displayed at the same time. The SC2000 current amplifiers * ac/ac displacement transducer includes four open collector limit (alarm) outputs plus peak and * dc/dc displacement transducer valley detection. * RTD temperature probes (Pt100) FEATURES * One to four channels * 6 digit display * "Sig cal" auto setup * Up to 800 Hz frequency response, field selectable * Pressure, load, displacement transducer, voltage, current, strain gage based sensor input * Alarm outputs * CE approved Model SC1000/SC2000 General SPECIFICATIONS Communications SPECIFICATIONS Characteristic Measure Characteristic Measure Model SC1000/SC2000 Serial setup and output RS-232/RS-485 Number of physical channels 1 to 4 Isolation 500 V Max. baud rate 38400 Number of virtual channels 1 to 7 Case material Aluminum Form factor 3/8 DIN Mounting Bench (standard) Size (W x H x D) 142,24 mm x 71,12 mm x 222,25 mm [5.6 in x 2.8 in x 8.75 in] Weight 1,81 kg [4 lb] Power SPECIFICATIONS Characteristic Measure Standard ac powered 100 Vac to 230 Vac, 47 Hz to 63 Hz Excitation drive 120 mA max. Not RoHS compliant Display SPECIFICATIONS Characteristic Measure Number of displays 1 Number of lines/display 2 Number of characters/line 16 Scaling Automatic or manual setup Max. display count 9999999 Decimal point selection 0 to 5 Display type Vacuum/Fluorescent Environmental SPECIFICATIONS Characteristic Measure Temperature, storage -29 C to 93 C [-20 F to 200 F] Temperature, operating 4 C to 41 C [40 F to 105 F] Special features (SC2000 only) SPECIFICATIONS Characteristic Measure Limits setup Front panel Limits output, standard Open-collector Limits output, relay output channel Contact relays Limits quantity 4 std., 16 max. (contact relays) Peak/valley hold on input channels Yes Digital, isolated control inputs 4 Approvals CE approved (except vehicle powered unit) Interfaces Signature calibration Input amplifier cards All input cards include non-isolated, open collector control inputs that can be field configured for any one of the following functions: 1) track hold, 2) peak/valley hold, 3) tare on, and 4) tare off. Input Strain gage millivolts High level volts/mA RTD millivolts ac/ac displacement transducer Transducer type Unamplified sensors Amplified pressure or load, dc/ dc displacement transducer Platinum 100 ohm, alpha = 0.00385 ac/ac displacement transducer Ranges* 0.5 mV/V to 11 mV/V @ 5V 0.5 mV/V to 5.5 mV/V @ 10 V 5 Vdc or 10 Vdc, 4 mA to 20 mA -200 C to 800 C [-328 F to 1472 F] 0.1 VRMS to 15 VRMS Frequency response See table below See table below See table below See table below Resolution See table below See table below See table below See table below Calibration type Shunt; mV/V; 2-, 3-, or 5-point known load Shunt; 2-, 3-, or 5-point known load 2-, 3-, or 5-point known load 2-, 3-, or 5-point known load Transducer excitation 5 Vdc or 10 Vdc with sense 15 Vdc, 28 Vdc, or 12 Vdc 10 Vdc 3 Vac @ 3 kHz Push button 100 % tare Yes Yes N/A Yes Push button shunt test Yes Yes N/A Yes * Ranges are field programmable, except for RTD input 2 Honeywell * Sensing and Control Transducer Display and Signal Conditioning Unit output Mounting dimensions and characteristics Output Strain gage millivolts High level volts/mA RTD millivolts ac/ac displacement transducer Voltage range (field selectable) 5 Vdc, 5 Vdc, 10 Vdc, 10 Vdc 5 Vdc, 5 Vdc, 10 Vdc, 10 Vdc 5 Vdc, 5 Vdc, 10 Vdc, 10 Vdc 5 Vdc, 5 Vdc, 10 Vdc, 10 Vdc Current range 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA Source Any channel Any channel Any channel Any channel Isolation 500 V 500 V 500 V 500 V Resolution 13 bits 13 bits 13 bits 13 bits Frequency response Same as input Same as input Same as input Same as input For reference only TYPICAL SYSTEM DIAGRAM Resolution (counts) (not including min. 10 % overrange/underrange capability) Frequency response (Hz) field selectable Step response (ms) typical Strain gage/RTD High level ac/ac displacement transducer 2 (fast mode) 40 50000 50000 25000 2 440 50000 50000 25000 8 110 25000 25000 15000 16 55 20000 25000 10000 32 28 10000 20000 10000 50 16 5000 15000 5000 100 8 5000 10000 5000 250 3 2000 10000 2000 500 2 2000 4000 2000 800 2 2000 2500 2000 Flexible and expandable platform options Honeywell * Sensing and Control 3 Model SC1000/SC2000 SC2000 capabilities Front panel or remote tare Flexible user setup mV/V or shunt calibration or five-point calibration Remote setup User selectable display options Different alarm configurations User selectable filtering Group and individual channel remote inputs 4 Honeywell * Sensing and Control Transducer Display and Signal Conditioning Unit SC2000 capabilities Open collector alarms or via optional four-relay cards Optional math channel can act like PLC Sig cal auto setup Analog and digital outputs Honeywell * Sensing and Control 5 Model SC1000/SC2000 Transducer Display and Signal Conditioning Unit Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008826-1-EN IL50 GLO June 2008 Copyright (c) 2008 Honeywell International Inc. All rights reserved.